ML20214C278
| ML20214C278 | |
| Person / Time | |
|---|---|
| Site: | Braidwood |
| Issue date: | 06/10/1986 |
| From: | Dewald I COMSTOCK ENGINEERING, INC. |
| To: | |
| References | |
| OL-A-021, OL-A-21, NUDOCS 8705200634 | |
| Download: ML20214C278 (10) | |
Text
6' RAM /, di%
QAStGI
"[f j
- =
i 00CKETED USNRC PROCEDURE TRACKING SHEET
'87 tv 31 All 3 PROCEDURE NO. A 3 -/O
[:.,
i l c 7 CG:,.E REVISION b
\\
Q j
a (9-al-9/-)l a
ma t
!?
N i
s INTERIM:
! $4 5!$
ki g%g4 iEi li i ',
-Q-k \\ h-
!D%
CECO INTERIM APPROVAL
- Effactive.
h %
b {
n
>q g
q)
FINAL:
i S & L/ CECO FINAL APPROVAL - \\O-4-9,4 hay}'l-ljj
- Effective
- IMPLEMENTATION DATE
- kO-2-9 i
SUPERCEDED BY REVISION E EPPROVED \\ O-lQ (Inter inal)
- Effective g*
- Effective Date - The data Q.C. received approval.
- Implementation Date - Tht effective date plus fifteen working days.
8705200638 860610 PDR ADOC>r 05000456 0
PDR FCR INF0f!MAimy 0ygy 045 '
L. L COINTOCK & COMPANY,INC.
QA SEM 4. '.
=
4.3.10 STORAGE, ISSUE AND CONTROL 0F WELDING MATERIAL PAGE REV/DATE 1
0 - 08/21/84 2
0 - 08/21/84 3
SARGENT & LUNDY I O - 08/21/84 1.
""a"a
- am"'o 0 - 08/21/84 4
'"I"I $ " "
- 8 'al aa
O - 08/21/84 5
F. A. KOSIK
[/*g C - 09/27/83 Form #57 c.,
carg Eo!
kO o!
Jh'85 0 - 08/21/84 Form #63 Attachment 'A' C - 09/27/83 Attachment 'B' 0 - 08/21/84 APPROVALS:
DATE ["d L. K. COMSTOCK AND COMPANY, INC.
UALITY CONTROL MANAGER h
,+
=
L. K. COMSTOCK AND COMPANY, INC. N A_
DATE9'[-([
PR'0 JECT MANAGER L. K. COMSTOCK AND COMPANY, INC. L b._ _
DATE 9 -G - $ '/
f0JfCT $INEER~
L. K. COMSTOCK AND COMPANY, INC.
h6 OATE 9 89 QA ENGINEER REV. 0 (08/21/84) 00851 EFFECTIVE DATE: 09/11/84 i -,
ans a w
l.. K. COMSTOCK O COMPANY, INC, Braidwood 4.1.in cASECT s
o 4.3.10 STORAGE, ISSUE AND CONTROL OF WELDING MATERIAL 1.0 REFERENCE 1.1 American Welding Society (AWS 01.1-75) 1.2 AWS AS.1 1.3 AWS A5.4 x
1.4 AWS AS.5 1.5 Nanufacturer's Technical Bulletins (Cheatron/McKay) 1.6 Calibration for Weld Ovens, Procedure 4.9.1 2.0 PURPOSE / SCOPE 2.1 To provide instruction for handling, storing and issuing weld filler.
metal.
2.2 To provide documentation source of weld activity by material issue records.
2.3
.To prevent use of unauthorized material for construction.
2.4 To list equipment rr;quirements for welders which are under warehouse control.
3.0 PROCEDURE 3.1 Classification of all weld filler metal (Electrodes) will be in accordance with referenced American Welding Society sections.
Reference Procedure 4.10.2, Section 3.1.6 for procurement activities.
3.2 Electrode Storage l
l 3.2.1 Welding electrodes will be stored by Phillips Getschow Co. in hermatically sealed containers.
The L. X. Comstock warehouse foreman will withdraw welding electrodes (in hermatically sealed containers) from Phillips Getschow Co. using the Phillips Getschow Co. Stores Request Form (Attachment 'B').
The stores request form will be filled out by Phillips Getschow personnel at the time of request for the electrodes and signed by L. Kt Comstock warehouse foreman.
h 004 Oafl V mo/m.a o,
paceAnco Appaoveo nevistci
- d e Vilit i4,, [
onlG. DATE REVISION PAGE ECE IFD DVB 02 M 8 D
1 of 5 PROCEDURE 08/21/84 0454
-.. ~ -,..
L. K. COMSTOCK O COMPANY, INC.-
Braidwood 4.3.10 QA SECT 3.0 PROCEDURE - continued A copy of the stores request form will be retained by the L. K.
Comstock warehouse foreman and given to the LKC QC Inspector who shall verify that there is a released MRR # and verify with ]
CEC 0 QA that certs are acceptable. Verification shall also include a check that the heat number is identified.
When weld rod is received directly by Comstock or requisitioned from site contractors other than P.G. Co., a copy of the MRR and/or applicable requisition will be placed in the stores request file. The MRR and/or requisition must show.
traceability from heat number to MRR number. The information will be entered in a. log cross referencing heat number, MRR number and description. No rod will be released to,the field until the MRR has been released (interim status as a minimum) by CECO QA.
3.2.2 Welding electrodes received by L. K. Comstock will be in the following containers:
3.2.2.1 E308/E309, E7018 - Hermatically sealed containers'.
3.2.2.2 E6013, E6010 - Clean dry containers.
,s 3.2.3 The electrodes will be transferred to L. K. Comstock warehouse and/or tool crib for storage. When sealed containers are opened, the electrode holder end of the rod will be painted white for identification.
]
3.2.3.1 E308/E309 and E7018 electrodes will be placed in temperature controlled electrode storage ovens.
3.2.3.2 E6010 and E6013 electrodes will be placed in separate clean, dry containers.
s T
C.
3.2.4 Electrodes of dissimilar chemical composition shall not be kept y-in the same storage oven.
3.2.4.1 All Tool Crib rod ovens and containers will be m.
i
- '5 labeled to indicate the classification and heat q
number of electrodes they contain.
f I) 3.2.5 The L. K. Comstock warehouse foreman / tool crib attendant shall
[J assure that the following' electrode storage oven temperatures i
A and conditions are utilized by production.
21
' ::s 3.2.5.1 TOOL CRI8 OVEN y
E308/E309 + 155' to + 205*F
)
p.
'.')
E7018 + 250' to + 800*F i
2, 3.2.5.2 The temperature of the tool crib storage ovens shall be monitored on a daily basis by the LKC warehouse
.[j foreman or tool crib attendant for the purpose of p=
setting the oven thermostat. A thermometer shall be paceanse neeaoveo arvisto Tirts onio.oart REVISION PAGE ECE g IFD DVB PROCEDURE 08/21/84 Q454
L. K.COMSTOCK & COMPANY,INC Braidwood 4.3.10
^
QASECT e.
3.0 PROCEDURE - continued placed inside the storage oven in a conspicuous place and the temperature shall be recorded on LKC QC Form
- 63. Forn 63 shall be located adjacent to the storage oven in open view. Form 63 shall be forwarded to i
L. K. Comstock QC at the end of each month for filing, (excluding Saturdays Sundays and Holidays).
3.2.5.3 E308/E309 and E7018 electrodes may be removed from the portable ovens during construction activity not to exceed a period of four hours, i
3.2.5.3.1 Electrodes that have been removed from
.j ovens more than four (4) hours shall be redried as described below or disposed of.
3.2.5.3.2 Redrying shall consist of heating the electrodes for at least two (2) hours at 450*F to 500*F for electrodes conforming to AWS AS.1, or for at least one (1) hour at 700*F to 800*F for electrodes conforming to AWS AS.S.
3.2.5.4 E6010. E6013 electrodes will be maintained at room temperature in separate, clean dry containers.
i 3.2.5.5 Electrodes that show any of the following conditions will be discarded.
3.2.5.5.1 Excessive moisture.
3.2.5.5.2 Objective coating blisters.
TD 3.2.5.5.3 Direct contact with water.
I D
i 3.3 Issuance of Material
==
M 3.3.1 The L. K Comstock warehouse foreman or tool crib attendant Q}
shall issue electrodes in clean dry containers for transporting }
"'T" to work areas.
==vm 3.3.1.1 E7018 shall be placed in designated portable rod i
ovens to maintain heating requirements at a minimum range setting o'f 250'F.
Nj 3.3.1.2 E309 shall be placed in designated portable ovens to
"""m maintain heating requirements of a minimum range C
setting of 155'F
~
3.3.1.3 Portable rod ovens shall be energized to maintain the Q
required heat levels.
N 3.3.1.4 Electrodes of the same, type and size but with dif ferent heat numbers shall. be segregated in the rod T
crib to insure traceability of rod is not losi:
PREPAREO APPRov E D REveSED TITLE ORIO. D ATE REV SiON PAGE ECE IFD DWB PROCEDURE 02/01/78 08/21/84 3 of 5 Q ASA i.
m L. K. COMSTOCK & COMPANY, INC.
Breidwood a.3.10 cA sect s
3.0 PROCEDURE - continued 3.3.2 A Filler Metal Withdrawal Authorization Form (Form #57) will be required for each type and size of electrode and shall be required for each welder. A new Form 57 will be required for each day's welding activity even if the activity is continued from a previous day's work.
3.3.3 Upon receipt of a completed Filler Metal Withdrawal Authorization Form (Form #57), the L. K. Comstock warehouse foreman or rod crib attendant will prepare a rod oven or clean dry container, as applicable, with the required rod and store the oven or container in the crib until it is requested by the welder. The ovens containing weld rod shall be kept heated per the requirements of Paragraph 3.2.5.1.
3.3.3.1 The Form 57 will be kept with the oven or container untti such time as the rod is requested by the welder.
3.3.3.2 Upon the presentation of a valid welder 10 card by the certified welder specified on the Form 57, the warehouse foreman or rod crib attendant shall issue the oven or container and rod to the welder and date stamp the Form 57.
3.3.2.3 The Form 57 shall be forwarded to the LKC QC Department for filing and logging in the Welding Log (See Attachment "A").
.3.3.4 Upon completion of the welding activity specified on the Form i
57, or at the end of each working shift, welders shall return j
y their rod ovens and rod containers to the rod crib.-
3.3.4.1 At the end of each working shift the LKC warehouse D
foreman or rod crib attendant shall verify that all rod ovens have been returned. Any ovens not returned shall be noted and.QC shall be notified.
D f.)7 3.3.4.2 The crib attendant shall remove any unused weld rod from the portable oven or containers and return it to
.% g the appropriate crib oven.
v..
0, f;3 3.3.5 The tool crib attendant shall not issue any E309 or E7018
[%g electrodes from the storage' ovens that have not been maintained as per Paragraph 3.2.5.1 of this procedure.
[ ] 3.4 Control of Weld Stubs and Spoiled Electrodes
- M 3.4.1 Each welder shall carry a stub pail for spent of spoiled j
electrodes and shall be near the work in progress.
Q 3.4.2 The welder shall deposit all disca'rded stubs (unused portion of i
l electrodes and spoiled rod) in the stub pail provided.
PREPAmEO APPROV E D REve5ED TITLE ORIG. D ATE REVISION PAGE ECE IFD DWB 02/01/78 D
4 Of 5 PROCEDURE 08/21/84 Q454 l
L. K. COMSTOCK Q COMPANY, INC.
3rcidwood 4.
10 i
{ *.
3.0 PROCEDURE - continued 3.4.3 The. welder shall discard any spoiled electrodes, using the stub pail provided. All electrodes which are solled, wet, contaminated, oil-impregnated or unidentifiable shall be considered " spoiled". Electrodes which have been " spoiled' shall be discarded and cannot be rebaked.
3.4.4 Each welder shall empty his pail daily at the end of his shift or at the completion of the welding activity. All stubs and spoiled electrodes shall be deposited in a locked, uniquely identified barrel. Stub pails shall be used for no other purpose.
3.4.4.1 Each foreman shall walk-down his immediate work area at the end of each shift or at the completion of welding activity to verify that no weld electrodes, stubs, or spoiled electrodes have been lef t out in open. All stub pails shall be locked up in gang boxes or deposited in the crib (s) during the off time.
3.4.5 Under no circumstances shall any filler metal be removed from stub palls or the designated receptacle for use in welding.
Such activity shall subject the welder to disciplinary action,
~
as deemed appropriate by the LKC Project Manager.
NOTE:
Each welder must consider the work to be performed j'
when withdrawing electrodes from the portable oven, in order to reduce waste of electrodes and to provide better control of weld stubs and spoiled material.
Use of low-hydrogen electrodes in conjunction with hot storage will minimize problems of hydrogen cracking welds. Observation of procedures will contribute substantially to weld quality by l.
eliminating hydrogen, which may be introduced by water, water vapor or hydrocarbons. Welders are encouraged to minimize the time between the withdrawal of electrodes from heated ovens and their use in i.elding.
4.0 TEST EQUIPMENT 4.1 None
,g p g g 1 -M j f*!!
I
- J 'i s U
,., f i
5.0 FORMS 4
5.1 Form 57 - Filler Metal Withdrawal Authorization 5.2 Form 63 - Electrode Storage Oven Temperature 9
6.0 SPECIAL INSTRUCTIONS 6.1 G. K. Newberg personnel shall be responsible for the painting, marking, securing, placing, and emptying of disposal barrels.
PREPARED APPROVE D REVISED TITLE ORIG. D ATE REVISION PAGE ECE IFD DWB 02/01/78 D
5 of 5 PROCEDURE 08/21/84 QASA
~..
-.,...,.- -- _ _ _ _ - -.-._ ~. m
..=
- .4 s
fx
@M O i.
. E s.o 8,. L e*
9a4 O.
E 3
TA l
l D
N E
O O
I N
T R
A T
I C
A H
o A
E 7
N I
H E
N
)
E E
v P
O W
u
(
0R T
S U
S O
A.
l N
C S
O G
E J
I N
Z I
T I
I A
R S
Z I
I I
E R
U D
O R
O N
R N
T T
O U
C 2
I A
E.
3 T
/
O l
A E
5 N
l T
A b
S W
C E
A I
c D
R N
D O
D A
O H
R W
T D
I I
W A
8 R
L
/
R A
I T
M e
NA R
I N
E E
L R
i L
V o
O I
E 2
m F
F R
3
/
y E
3 S
S
~
U I
O N
T E
N
)
R S
A E
P E
W F
W Z
/
I
(
I T
U S
N Q
E A
E R
E D
/
U D
N T
D O
E R
E R
Y T
O C
T B
T P
O C
A P
R E.
D U
P l
E E
S E
Z I
/
G G
I R
R N
N D
R C
n0 E
I I
E C
W D
T 1
N A
L A
u l
I i
O f
A R
E D
e l
D H
D W
C W
A 1
)]L l_
w., n I I. y g
l.S
- a..
,.s%
~
.r n
.,*',<l
'-t
~
^:
=AI o
,I
=* jo
=.R o i f :;
Rs9 2E+
a MO gE Hy 3Roocy n oO*
m 3tC e O
.II
!!II l
,I' 4
- -... - - -...~._,_, -.._.._.._ _ -. -. _.-. ~.... ~...,~.-,. ---,.
, ~.._...- -,.
es
- g *.
,ss f'
t 4
Um em
- G GM
(**
e BN a
p y,
M w
C I
M S
l N
ll l
N N
98
\\
f f
l f
f f
f l
I I
I U%
f l
i N
g I
e f"i l
N N
l l
N M
.e f!
- dls N
C S
=
4 ed e
9 4
M i'f W
e4 W
.w s
tri r=4 1s 4
)3 N
l M
s k
l' N
N
>ms and O
eJ h
4 O
S i
M e.am aid l'
(g e
..--.s n
em l
W
?
-l eas e
y
~
4
.4p c
s r
m,
~n i
5O $
cu a
I t
N 4
l
,*j "c"!
-u M
[
,.u-1 i
..ra. %
v.
O a
3
~w
~
f y
ke., suis
- 4 >* % A O m2 %
eusa **
h i#
s:-.a a
samm*
l l
t'
,smus W
CD g
3 l
,- - - -,--._ _ _,_,n.-=,-n-, _,
_ _n n n, - -
.,_-n
,,,,.,,--n n
i 1
e.
Braidwood 4.3.10
~.
attachment "B" l
t
- LLIPS, GETSCHOTY CO Fs STORES REQUEST Td
. ~ ~,,
2..-,
1 I
1 ll l
l 1
4 I
l
's s
l j
l I
.i.
l 1l l
g
.O l
l 5
t i
I L
i
- = -
- wa=4 s eene g
t i
j! ~ f ;(:9 N,911 s1 ?'
rw a.
Rev. D
,ss y i
Vj i
t'd 8/21/84 s' i h. u s a, d
- er d V j g.
i i
.