ML20214B083

From kanterella
Jump to navigation Jump to search
Comments on Proposed Rule 10CFR50 Re Revised App J on Integrated Leak Rate Test.Recommends That Old App J Version Be Withdrawn Until Pristine Version Can Be Created.List of 32 Cases in Which Reg Guide Formulas Applied Encl
ML20214B083
Person / Time
Issue date: 04/20/1987
From: Renton T
TER TESTING, ENGINEERING & RESEARCH SERVICES
To: Arndt G
NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES)
References
FRN-51FR39538, RULE-PR-50 TER-87-007, TER-87-7, NUDOCS 8705200110