Text

_..

4 Pubhc Service Electric and Cas Company Cerbin A. McNeill, Jr.

Pubhc Service Electnc and Gas Company P.O. Box 236, Hancocks Bridge, NJ 08038 609 339-4800 Vice President -

Nuclear Novenber 10, 1986 NLR-NE6168 Director of Nuclear Reactor Regulation United States Nucleur Regulatory Commission 792 0 Norfolk Avenue Bethesda, Ma ryland 20814 Attention:

Ms. Elinor Adensam, Director i

Project Directorate #3 Division of BWR Licensing

Dear Ms. Adensam:

REQUEST FOR ADDITIONAL INFORMATION RADIOLOGICAL EFFLUENT TECHNICAL SPECIFICATIONS HOPE CREEK GENERATING STATION DOCKET NO. 50-354 Public Service Electric and Gas Company (PSE&G) submitted an Emergency Request for Amendment to Facility Operating License NPF-57 for the Hope Creek Generating Station (HCGS) on September 12, 1986, and subsequently downgraded the requests' classi-i fication from an Emergency Request to a standard License Change Request on September 22, 1986.

Based upon discussions with members of the Nuclear Regulatory Commission (NRC) staff and a review by HCGS personnel, editorial changes to Technical Specification Action Statements 3.3.7.9.b and 3.3.7.10.b are desirable to increase clarity.

The changes included as Attac hment 1 are based upon the Standard Radiological Effluent Technical Specifications for Boiling Water Reactors (NUREG- 0473, Revision 3) dated March and September 1982.

Should you have any questions or comments on this transmittal, do 3

not hesitate to contact us.

Sincerely, s.-

^

,; o v -

u" g0f g4(/ (3 8 k Attachment 8611190083 861110 sh l

PDR ADOCK 05000354 P

PDR

o i

Director of Nuclear 2

11-10-86 Reactor Regulation C

Mr.

D.

H.

Wagner Licensing Project Manager Mr.

R.

W.

Borcha rd t Senior Resident Inspector Mr. Gerald Nichols, Assistant Director Bureau of Radiation Protection Department of Environmental Protection 38 0 Scotch Road Trenton, NJ 08628 Honorable Charles M. Oberly, III A'ctorney General of the State of Delaware 82 9 North French Street i

Wilmington, DE 198 01 i

.)

i l

I e

]

O o

k l

i

. -... _ _ _... ~, _

\\

INSTRUMENTATION RADIOACTIVE LIQUID EFFLUENT MONITORING INSTRUMENTATION LIMITING CONDITION FOR OPERATION 3.3.7.9 The radioactive liquid effluent monitoring instrenentation channels shown in Table 3.3.7.9-1 sna11 be OPERABLE with their Alarrt/ Trip Setpoints set to ensure that the limits of Specification 3.11.1.1 are not exceeded.

The Alarm / Trip Setpoints of these channels shall be determined and adjusted in accordance with the methodology and p rameters in the OFFSITE DOSE CALCULATION MANUAL (00CM).

APPL' E*LI' At e'l times.

ACTION:

a.

With a radioactive liquid effluent monitoring instrumentation ct.annel Alarm / Trip Setpoint less conservative than required by the above spec-ification, immediately suspend the release of radioactive liquid ef-fluents monitored by the affected channel, or declare the channel in-operable, or change,the setpoint so it is acceptably conservative.

{

b.

With less than the minimum number of radioactive liquid effluent monitorina instrumentation channels OPERABLE, take the ACTION shown in Table 3.3.7.9-1.hluster; th in;;;re:;1; instrant; ten to FX41 BS7~

OPERA 8LE status within 30 days and, if unsuccessful, expla W EFFCR75 in the next Semiannual Radioactive Effluent Release Rsport pursuant 0 RETuR/J to Specification 6.9.1.7 why this inoperability was not corrected 7pg-in a timely manner.

nBnhun&XS The provisions of Specifications 3.0.3 and 3.0.4 are not applicable.

t c.

SURVEILLANCE REQUIREMENTS 4.3.7.9 Each radioactive liquid effluent monitoring instrumentation channel shall be derunstrated OPERABLE by performance of the CHANNEL CHECK, SOURCE CHECK, CHANNEL CAL 18 RATION, and CHANNEL FUNCTIONAL TEST at the frequencies shown in Table 4.3.7.9-1.

i i

i 3/4 3-91 HOPE CREEK 1

  • f

INSTRUMENTATION.

RADI0 ACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION LIMITING CONDITION FOR OPERATION 3.3.7.10 The radioactive gaseous effluent monitoring instrumentation channels shown in Table 3.3.7.10-I shall be OPERABLE with their Alarm / Trip Setpoints set to ensure that the limits of Specifications 3.11.2.1 and 3.11.2.6 are not exceeded.

The Alarm / Trip Setpoints of these channels meeting Specification 3.11.2.1 shall be determined and adjusted in accordance with the methodology and parameters in the 00CM.

APDLIC MIL *TY:

As snew.) ia Table :.3.7.10-1.

ACTIC:4:

a.

With a radioactive gaseous effluent monitoring instrumentation channel Alarm / Trip Setpoint less conservative than required by the above spec-ification, immediately suspend the release of radioactive gaseous ef-fluents monitored by the affected channel, or declare the channel in-operable, or change the setpoint so it is acceptably conservative.

l b.

With less than the minimum number of radioactive gaseous effluent monitorina instrumentation channels OPERABLE, take the ACTION shown in Table 3.3.7.10-1.N "u tcr: the i = n r:b1: 1 :tr_-.t:ti:M to OPERABLE status within 30 days and, if unsuccessful, explain

  • l E

d in the next Semiannual Radioactive Effluent Release Report pursuant i

D MV to Specification 6.9.1.7 why this inoperability was not corrected T/t in a timely manner.

It)SifMEaT5

\\

c.

The provisions of Specifications 3.0.3 and 3.0.4 are not applicable.

l SURVEILLANCE REQUIREMENTS l

4.3.7.10 Each radioactive gaseous effluent monitoring instrumentation channel shall be demonstrated OPERABLE by performance of the CHANNEL CHECK, SOURCE CHECK, CHANNEL CALIBRATION and CHANNEL FUNCTIONAL TEST at the frequencies shown in Table 4.3.7.11-1.

HOPE CREEK 3/4 3-96 1