Forwards Reactor Containment Bldg Integrated Leakage Rate Rept, Per 10CFR50,App J.Rept Provides Summary of Results of Preoperational Integrated Leakage Rate Test Conducted During Feb 1987.W/o Encl
ML20213H008
Person / Time
Site: Beaver Valley
Issue date: 05/11/1987
From: Crockett J
DUQUESNE LIGHT CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
Shared Package
ML20213G991 List:
References
ND2MNO:1452, NUDOCS 8705190095
Download: ML20213H008 (2)


Text

-

b das

'Af Telephone (412) 393-6000 Nuclear Group

$i op$p'o,1, PA 15077-0004 May 11, 1987 ND2MNO:1452 U. S. Nuclear Regulatory Commission Attn:

Document Control Desk Washington, DC 20555

Reference:

Beaver Valley Power Station, Unit No. 2 Docket No. 50-412 Reactor Containment Building Integrated Leakage Rate Report Gentlemen:

Enclosed is the Beaver Valley Unit No. 2 Reactor Containment Building Integrated Leakage Rate Report submitted in accordance with Appendix J of 10 CFR Part 50.

The report provides a summary of the results of the Preoperational Integrated Leakage Rate Test conducted at BVPS Unit No. 2 during February 1987.

Also submitted with this report is a summary of results for all Local Leakage Rate Testing performed prior to the Pre-Operational Integrated Leakage Rate Test.

Very truly yours, J. O. Crockett Senior Manager Nuclear Operaticns Attachment l

l l

8705190095 870512 l

PDR ADOCK 05000412 l

A PDR 1

r

,.Benvar Vollsy Powsr Station, Unit No. 2 Dock 3t No. 50-412 Reactor Containment Building Integrated Leakage Rate Report Page 2 cc: Mr. W. M. Troskoski, Resident Inspector U. S. Nuclear Regulatory Commission Beaver Valley Power Station Shippingport, PA 15077 U.

S. Nuclear Regulatory Commission Regional Administrator Region 1 631 Park Avenue King of Prussia, PA 19406 Mr. Peter S. Tam U. S. Nuclear Regulatory Commission Project Directorate No. 2 Division of PWR Licensing - A Washington, DC 20555

- Mail Stop 340 Addressee only Director, Safety Evaluation & Control Virginia Electric & Power Company P.O. Box 26666 One James River Plaza Richmond, VA 23261

-