ML20213G258

From kanterella
Jump to navigation Jump to search
Forwards Requalification Program Evaluation Rept 50-054/87-02OL of Exam Administered on 870327.Requests Review & Assessment of Info & Individual Exams within 30 Days of Ltr Date
ML20213G258
Person / Time
Site: 05000054
Issue date: 05/08/1987
From: Collins S
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Mcgovern J
CINTICHEM, INC.
Shared Package
ML20213G260 List:
References
NUDOCS 8705180209
Download: ML20213G258 (2)


See also: IR 05000054/1987002

Text

f0I

_

,

>p

4

Docket No. 50-54

Cintichem, Inc.

ATTN: Mr. James J. McGovern

Plant Manager

Po'st Office Box 324

Tuxedo, New York 10987

. Gentlemen:

Subject: -REQUALIFICATION PROGRAM EVALUATION REPORT NO. 50-54/87-02 (OL)

On March 27, 1987, the NRC administered a written requalification examination

to ten of your licensed operators.

The purpose of this examination was to

assess the impact on operator knowledge of your past -practice of allowing

unproctored facility administered written requalification examinations iden-

tified in NRC Inspection Report No. 50-54/86-02.

The results of this evaluation are documented in the Region I Evaluation Report

which is enclosed with this letter.

In a telephone conference held on

May 6,1987 with you and other members of your management, we expressed our

- perception of the significant aspects of these results. Our specific' concern

is that senior operators may be deficient in the area of theoretical knowledge

due to a weakness in the requalification training program. During this con-

versation, we . requested that you review and assess the 'information provided in

this report and in the individual examinations, copies of which are being

returned under separate cover.

Please provide us with your response or

intended actions within 30 days of the date of this letter.

This request for information was approved by the Office of Management and '

Budget under Clearance Number 3150-0101, which expires May 31, 1989. Comments

on burden and duplication may be directed to the Office of Management and

Budget,

Reports

Management

Room

3208,

New

Executive

Office

Building,

Washington, D.C. 20503.

l

!

-r

-

,

h

4

.

$

!

.

!

0FFICIAL RECORD COPY

OL REQUAL CINTICHEM - 0001.0.0

! !

'

0705180209 B70508

l

PDR

ADOCK 05000054

V

PDR

_.-

. . . _ , ._ _ _ _ . _ _ _ -

_

_ _. _ . .

- . _

.

_

_

_ - _ .

e.

+

.

Cintichem, Inc.

2

Thank you for your. consideration in this matter. If you have any questions on

the' evaluation process, please contact Mr.

R.

M.

Keller, Chief, Reactor

--

Projects Section IC, at~ 215-337-5211.

Sincerely,

Oe p al sip,ed

L p

7

Samuel J. Collins, Deputy Director

Division of Reactor Projects

-Enclosure: As stated

cc w/ enclosure and Attachments 1, 2 and 3:

W. Ruzicka, Operations Manager

D.'Gallaher,

President for Cintichem Operations

C.-Konnerth, Manager, Site Operations

-D. Grogan, Manager, Radiochemical Production

bcc w/ enclosure w/o Attachments 1, 2 and 3:

Region I Docket Room (w/ concurrences)

DRP Section Chief

D. Coe, Examiner

Chief, OLB, DLPQE, NRR

Master Exam File (With All Attachments)

RI:

P

RI:pP

RI:0RP

R)

D

-

g

er

/ Col

Coe

a/mjd

Kell

[d No

olm

allo

ns- --

5/ {

7

5/k/87

5/J/87

Sh/87

5/8/87

5/ D 87

/

0FFICIAL RECORD COPY

OL REQUAL CINTICHEM - 0002.0.0

05/07/87