Submits Status Rept for Wk of 870413-19.EPA Sample Analysis Results Show That TMI Site Liquid Effluents in Accordance W/ Regulatory Limits,Nrc Requirements & City of Lancaster Agreement
ML20212R333
Person / Time
Site: Crane 
Issue date: 04/20/1987
From: Travers W
Office of Nuclear Reactor Regulation
To: Crutchfield D, Schroeder F
Office of Nuclear Reactor Regulation
References
CON-NRC-TMI-87-034, CON-NRC-TMI-87-34 NUDOCS 8704270113
Download: ML20212R333 (3)


Text

~-

w-se O

1 April 20, 1987 nttt/ stu-c/-UJ4 HEMORAhDUM FOR:

Dennis M. Crutchfield, Director Division of Reactor Projects - III,IV,Y & Special Projects Frank Schroeder, Jr., Assistant Director Region IV Reactors and Special Projects FROM:

William D. Travers, Director TMI-2 Cleanup Project Directorate

SUBJECT:

NRC TMI-2 CLEAh0P PROJECT DIRECTORATE WEEKLY STATUS REPORT FOR APRIL 13 - 19, 1937 1.

D_EFUELING Pick and place fuel removal continued. Various light duty tools were used to remove fuel pin sections and place them in canisters.

The air lif t tool was then used to fill the interstitial spaces with smaller debris.

Two canisters were filled with debris. One of them was t ansferred to the spent fuel pool.

2.

EliVIRONMENTAL MONITORING US Environmental Protection Agency (EPA) sample analysis results show that TMI site liquid effluents are in accordance with regulatory limits, NRC requirements, and the City of Lancaster Agreement.

TMI water effluents are sampled from the etation (Units 1 and 2) discharge and analyzed by EPA.

Gama spectrum analyses of the seven daily ccmposited samples for March 28 - April 04, 1987 indicated no TMI-2 related radicactivity.

EPA', gasso spectruni analysis of the NRC's IMI outdoor air sa:nple for April 9 - 16, 1987 shcwed no reactor related radioactivity.

The water works for the City of Lancaster composited seven daily samples frca March 29 - April 4, 1987.

EPA's gamma spectrum analysis of the con,posite semple showed no reactor related radioactivity.

3.

DEC0'iTA*11 NATION ACTIVITIES Desludging of the auxiliary building sump continued.

Robot desludging of the reactor building basement continues.

Robot scabbling in the seal injection valve room resumed.

8704270113 870420 ome. >

PDR ADOCK 05000320 p

PDR SURNAME >

on.>

sac Fonu na no so) Nacu o o OFFICIAL RECORD COPY

Dennis H, Crutchfield 2

April 20, 1987 NRC/TMI-87-034 Frank Schroeder, Jr.

4.

hRC EVAiUATIONS IN PROGRESS Cempi e i.e_d a.

Technical Specificatico Change Request numbers 49 and 51 and the associated Recovery Operutions Plan Change Requests 31 and 33 were approved on April 17, 1987.

In Progress b.

Techtiical Specification Change Requests 52. 55 and 56.

Solid Maste Facility Technical Evaluation Report.

Heavy Load Safety Evaluation Report, Revision 3.

Processed Water Disposition Proposal.

Safety Evaluation Report for Use of Plasma Arc Cutting Torch.

Tetrporary keactor Vessel Filtration System Safety Evaluation Report, Revision 3.

Pressurizer Defueling Safety Evaluation Report.

Safety Evaluation Report for Defueling of the Core Support Assembly.

Canister Handling and Preparation for Shipment Safety Evaluation Raport, Revision 4.

5.

FEETING The Advisory Panel for the Decentaaination of Three Mile Island Unit 2 met with the NRC Commissioners cn April 16, 1987, in Washington, DC en the issue of TMI-2 accident-generated water disposal.

Prior to the meeting, Panel Chairtr.an Arthur E. Perris in a letter (3-31-87) to Chairman Zech noted the following Panel actions:

1)

A tr.otion that "the Draft Supplement to the Environmental Impact dealing with the disposal of the accident-generated water is an acceptable document" possed with a vote of eight (8) for and two (2) against.

A motion to " oppose the evaporation option" put forth by GPU was 2) passed with a vote of five (5) for, fcur (4) against and one (1) abstention.

3)

A motion to " maintain the status quo until a stronger case can be mode for definitive ection, including evaporation or a more desirable altcraativc".::: nct appreved dus to a vote of five (5) for and five (5) against.

At the meeting the Comaission and the Panel discussed this issue further.

The Panel was asked to provide the Commission with its view on when the disposal issue should be ultimately resolved.

William D. Travers Director TMI-2 Cleanup Project Directorate hr

" ' ' ' >.TMICPd.

TMICPD W TMf TMICPD su a" > DJCollins:wa.CJCowgill.

.JATh W as WDTravers -

. /.,/87 4

4

. /a0/87,,

... /2487 4h/87 4

om>

NRC FORM 318 (1080) NRCM O240 OFFICIAL RECORD COPY

Dennis M. Crutchfield 3

April 20, 1987 Frank Schroeder, Jr.

NRC/THI-87-034 INTERNAL DISTRIBUTION CENTRAL FILE NRC PDR LOCAL PDR EDO OGC EPA DOE i

RI Regional Administrator RI Division Directors Public Affairs. RI State Liaison, RI 1

TMI HQ r/f TMI SITE r/f TMI-2 Project Section File TMI-1 Resident Office (5)

TMI Cleanup Project Directorate (14) i i

e i