Monthly Operating Rept for Dec 1986
ML20212P225
Person / Time
Site: Ginna 
Issue date: 12/31/1986
From: Kober R, Mcnamara A
ROCHESTER GAS & ELECTRIC CORP.
To:
NRC OFFICE OF RESOURCE MANAGEMENT (ORM)
References
NUDOCS 8703160034
Download: ML20212P225 (6)


Text

\\

.. OPERATING DATA REPORT DOCKET NO.

50-244 DATE January 13. 1987 COMPLETED BY [A 9 # E M'riC %

2 Andrew E. 1[cNamara TELEPHONE 315-524-4446 Fxt. 301 OPERATING STATUS Ginna Station

1. Unit Name:

R.E. GINNA NUCLEAR POWER PLANT Notes

2. Reporting Period:

December. 1986

'lhe unit operated the entire 190

3. I..scensed Thermal Power (MWt):

rienth with no shutdowns or 440

4. Nameplate Rating (Gross MWe):

significant power reductions 470

5. Design Electrical Rating (Net MWe):

to report. See page 4 for

6. Maximum Dependable Capacity (Gross MWe):

490 additional details.

470

7. Maximum Dependable Capacity (Net MWe):
8. If Changes Occur in Capacity Ratings (Iceras Number 3 Through 7) Since Last Report, Give Reasons:
9. Power Level to which Restricted, if Anh (Net MWe):
10. Reasons For Restrictions, if Any:

This Month Yr.-to-Da te Cumulative 744 8,760.00 149.880.00

11. Ilours la Reporting Period i

i 744 7,716.8 116.003.97 l

12. Number of flours Reactor Was Cr.tical 0

0 1_687.55*

13. Reactor Reserve Shutdown Ilours 744 7,659.75 113,684.38
14. Ilours Generator On.Line 0

0 8.5*

15. Unit Reserve Shutdown Ilours 1,121,160 11.327.424 159.050.049 h
16. Gross Thermal Energy Generated (MWH) 378,954 3,795,756 52,088.612
17. Gross Electrical Energy Generated (MWil) 360,887 3,610,266 49,413,583

!"N

18. Net Electrical Energy Generated (MWil) 100%

87.44%

75.85%

19. Unit Service Factor 100%

87.44%

75.86%

j

20. Unit Availability Factor 103.2%

87.69%

71.68%

21. Unit Capacity Factor (Using MDC Net)
22. Unit Capacity Facht (Using DER Net) 103.2%

87.69%

71.68%

l t1 0%

1.04%

6.93%

23. Unit Forced Outage Rate
24. Shutdowns Scheduled Over Next 6 Months (Type, Date and Duration of Each):

l l @b Fbbruary 7, 1987 - Annual Refueling and Maintenan l %

i IDo.E' f

25. If Shur Down At End Of Report. Period, Estimated Date of Startup:
26. Units In Test Status (Prior to Commercial Operation):

Forecas t Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION l

  • Ctmmulative Total Comencing January 1,1975 nrv *n *a g4 I.l s i
a.
  • AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.

50-244 UNIT R.E. Ginna Nuclear Power Plant DATE January 13. 1987 COMPLETED BY W J.}WW1hm Andrew E.'McNamara TELEPHONE 1 (315) 524-4446 Ext. 301 at Ginna MONTH December, 1986 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

(MWe-Net) 1.

483 17.

481 2.

483 18.

482 3.

484 19.

484 4.

488 20.

483 5.

488 21.

482 6.

489 22.

482 7.

488 23.

484 8.

489 24.

484 9.

489 25.

484 10.

489 26.

484 11.

487 27.

484 12.

488 28.

484 13.

489 29.

484 14.

489 30.

484 15.

488 31.

482 16.

481 INSTRUCTIONS On this format, list the average daily unit power level in MWe-Net for each day in the reporting month.

Compute to the nearest whole megawatt.

l

IXX:KET NO.

50-344 tlNITNAME R.E CENNA NUCLEAR POWER PLANT." '

2 I

UNIT SHUTDOWN AND POWER REDUCTIONS DATE January 13. 1987 COMPLETED IlY -

d. M W - - -

l Andrew E. McNamhra

~

REPORT MONTH DECErfMR, 1986 TELEPilONE 115-524-4446 M. 301 l

Ginna Station l

M

  • oE N

g, ja Cause & Corrective c

Licensee

,o '2

}.c v e

  • j Event No.

Date

{

gg 2

1-g Action to I' Port #

Au

!u Prevent Recurrence l

8-g$ E j

  • o e

2 g

u o

i No outages or significant power reductions to report.

i i

i 4

1 2

3 4

F: Forced Reason:

Method:

Exhibit G - Instructions S: Scheduled A-Equipment Failure (Explain) 1-Manual for Preparation of Data B-Maintenance or Test 2-Manual Scram.

Entry Sheets for Licensee.

l C-Refueling 3-Automatic Scram.

Event Report (LER) File (NUREG-D-Regulatory Restriction 4-Other (Explain).

0161)

E-Operator Training ac License Examination F-Administrative G-Operational Error (Explain) 5 E

ctv. 44s 49.e, 11-O:her (Explain)

Exhibit 1 - Same Source

c

  • NARRATIVE

SUMMARY

OF OPERATING EXPERIENCE DOCKET NO.

50-244 UNIT R.E. Ginna Nuclear Power Plant DATE January 13. 1987 COMPLETED BY (W E Mec 1

Andrew E. McNamara TELEPHONE 1 (315) 524-4446 EXT. 301 at Ginna I

MONTH December. 1986 The reactor power level was maintained at 100% through the 16th of the month.

On the 17th a Periodic Test on the Auxiliary Feedwater Pumps necessitated a power level reduction to - 98.5%

for a short period of time.

The power level was restored to 100%

l after completion of the test.

From December 19, through December 30, calorimetrics were performed using the leading edge flowmeter and the power level was not increased to 100% due to low feedwater pump suction pressure.

On December 31 the calorimetrics were performed using the feedwater venturis which indicated the power level to be at 100% due to feedwater venturis fouling.

Reactor power levels ranged from 98.30% to 99.55% during this period.

GINNA STATION MAINTENANCE REPORT

SUMMARY

DECEMBER, 1986 During the month of December, routine maintenance and inspections were completed.

Major safety related work included:

a.

M-40 Snubber Inspection (monthly) b.

  1. 1 SPING Monitor - P.M.

Inspection c.

  1. 2 SPING Monitor - P.M. Inspection d.

R-13/14 Radiation Monitor - P.M.

Inspection "B" Charging Pump - Trouble Shoot (Control Problem) e.

f.

Spare Service Water Pump Bowl Assembly - Rebuild g.

V-10017 Sample Valve - Replaced h.

RV-5135 Electric Fira Pump - Tested

-.w

,r,-_,

O'i.

x, F:

....j i ~",' +

c?

w RWil,iM1

$ ;, i ff }"Q c;i;1 ROCHESTER GAS AND ELECTRIC CORPORATION s 89 EAST AVENUE, ROCHESTER, N.Y. 14649-0001 ROGER W. Mot 3ER y

g E[c~12[EExmn

^"^c c'7'.

54 c.2 7 oo GINNA STATION January 13,-1987 Director, Office of Management Information and Program Analysis U.S. NUCLEAR REGULATORY COMMISSION Washington, DC 20555

Subject:

Monthly Report for December, 1986 Operating Status Information R. E. Ginna Nuclear Power Plant Docket No. 50-244

Dear Sir:

Pursuant to our Technical Specification 6.9.1, attached herewith is the monthly operating status report for Ginna Station for the month of December, 1986.

V truly yours, sp Roger W. Kober RWK/eeh Attachments cc: