ML20212N942
| ML20212N942 | |
| Person / Time | |
|---|---|
| Issue date: | 03/09/1987 |
| From: | Roberts J NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| To: | Haelsig R NUCLEAR PACKAGING, INC. |
| References | |
| REF-PROJ-M-44 NUDOCS 8703130214 | |
| Download: ML20212N942 (2) | |
Text
-
- 4 l
.g, -
3-Q3F II : 4 DICldd3ICf58l 200F _ _
E 9 % CAF.
File:
(WV1D-hojo !/ Mrk I
i OQcr __ __.. _
I Project No. M-44
' pg?
w.- _...__
Nuclear Packaging, Inc.
- ATTN:. Richard T. Haelsig
. f-1010 So th Street u
~
i.
Federal Way, Washington 98003 Gentlemen, I
By letter dated February 23, 1987, Nuclear Packaging Inc. (NuPac) submitted Revision 1 of its quality assurance program description for the design and fabrication of concrete storage casks, "10 CFR 72iSubpart G Quality Assurance Program for Design and Fabrication of Concrete Storage Casks," letter number QA-86-2, Revision 1, dated February 18, 1987.
I We have reviewed this submittal against the requirements of Subpart G of 10 CFR 72
' ~
as reflected in our Branch Technical Position on Quality Assurance Programs for Independent Spent Fuel-Storage Installations. We have also reviewed it against the Request for Additional Information which was forwarded to NuPac by our letter of~ December 3, 1986. We find that Revision:1 acceptably responds to these docunents and that it describes an acceptable quality assurance (QA) program for the design and fabrication of concrete storage casks for long-term interin storage of-irradiated fuel elements. When properly implemented, the QA program described by NuPac meets the requirements of 'Subpart G of 10 CFR 72 and the acceptance criteria stated in our Branch Technical Position on Quality l
Assurance Programs for Independent Spent Fuel. Storage Installations.
In implementing your QA program with respect to the development and design of the NuPac CP-9 cask and, in particular, with respect to your proposed CP i Scale Model Test Program, we recommend that you contact Mr. John G. Spraul 1 -
(301-492-4530) if you have any questions. Mr. Spraul is with the Quality,
(
Assurance Branch of the Division of Quality Assurance, Vendor and Technical l
Center Programs (QAVT), Office of Inspection and Enforcement.
1 l
J 4
i 0703130214 870309 PUR PROJ M-AA PDR
NAR 9 my Nuclear Packaging Inc.
2 When you have submitted your topical report with your proposed test program, we shall review these. Assuming that your test program is accepted, I request that you infom QAVT through Mr. Spraul prior to commencement of any testing, so that an opportunity;for inspection is provided.
Sincerely, Origing signed W Jol. P. Roberts John P. Roberts Advanced Fuel and Spent Fuel Licensing Branch Division of Fuel Cycle and Material Safety DISTRIBUTION:
Project T11e M Y PDR NMSS 'r/f FCAF r/f JPRoberts LCRouse JGSpraul FBrown
, n0 At n
I.
___I.
NAME:J oberts/jrIJGSpraul :LCRouse' DATE:03/9/87
- 03/ 9/87 :03f/'/87 gFFICIAL RECORD COPY I