ML20212N879

From kanterella
Jump to navigation Jump to search
Responds to IE Bulletin 86-002, Static O-Ring Differential Pressure Switches. Facilities Do Not Use Sor,Inc Series 102 & 103 Differential Pressure Transmitters in Important to Safety Applications Per 10CFR50.49(b)
ML20212N879
Person / Time
Site: Brunswick, Robinson, 05000000
Issue date: 07/28/1986
From: Cutter A
CAROLINA POWER & LIGHT CO.
To: Grace J
NRC
References
IEB-86-002, IEB-86-2, NLS-86-283, NUDOCS 8609020019
Download: ML20212N879 (1)


Text

g V

J Cp&L Carolina Power & Light Compcny SERIAL: NLS-86-283 gg Dr. 3. Nelson Grace, Regional Administrator United States Nuclear Regulatory Commission

(?

Suite 2900 101 Marietta Street, NW Atlanta, GA 30303 H. B. ROBINSON STEAM ELECTRIC PLANT, UBJIT NO. 2 21 DOCKET NO. 50-261/ LICENSE NO. DPR-23 G

Z BRUNSWICK STEAM ELECTRIC PLANT, UNIT NOS.1 AND 2 1

DOCKET NOS. 50-325 & 50-324/ LICENSE NOS. DPR-71 & DPR-62 RESPONSE TO IE BULLETIN NC. 86-02: STATIC "O" RING O!FFERENTIAL PRESSURE SWITCHES

Dear Dr. Grace:

On July 21,1986, Carolina Power & Light Company received IE Bulletin No. 86-02, Static "O" Ring Differential Pressure Switches, requesting that licensees of nuclear power reactors take certain actions if SOR, Inc., Series 102 and 103 differential pressure transmitters are used in important to safety applications as defined in 10 CFR 50.49(b).

We have reviewed the applicable plant documentation and determined that Robinson Unit No. 2 and Brunswick Unit Nos. I and 2 do not utilize SOR, Inc., Series 102 and 103 differential pressure transmitters in important to safety applications as defined in 10CFR50.49(b). Therefore, no further action is required in response to the bulletin.

If you have any questions, please contact Mr. Pedro Salas at (919) 836-8015.

You very y,

J A. B. Cutter - Vice resident

. Nuclear Engineering & Licensing ABC/PS/crs (4031PSA) cc:

Mr. W. H. Ruland (NRC-BNP)

Mr. G. Requa (NRC)

Mr. H. Krug (NRC Resident Inspector - RNP)

Mr. E. Sylvester (NRC)

USNRC, Document Control Desk A. B. Cutter, having been first duly sworn, did depose and say that the information contained herein is true and correct to the best of his information, knowle e and belief; and the sources of his information are of ficers, employees, contractors, an agents of Carolina Power & Light Company.

YYW$

f ~ ' Notary Dem) f

.r ' ~,,.

My commission expires: //

9 p.

c.h

~

411 Fayettevsita.Saseeb*

  • 1
  • Raleegn, N C 27602 kI IUsLiC d

8609020019 960728

/

u PDR ADOCK 00000261 OFFICIAL COPY gg/

G PDR lg Q

  • aesop *,

-