/'Qt22 March 9, 1987 NRC/THI-87-019 HEMORANDUM FOR:
Harold R. Denton, Director
^
Office of Nuclear Reactor Regulation Frank J. Miraglia, Director Division of PWR Licensing-B j
FROM:
William D. Travers, Director THI-2 Cleanup Project Directorate i
SUBJECT:
NRC M LEANUP PROJECT DIRECTORATE WEEKLY STATUS REPDRT FOR Mo,RCH 2 - 8, 1987 1.
DEFUELING Defueling continued using the standard tooling. All end fittings have been pulled from the peripheral fuel assemblies. GPUN is in the process of cutting nominal five foot segments from the peripheral fuel elements and placing the segments into fuel canisters. Two canisters were filled.
2.
ENVIR0hMENTAL MONITORING US Environmental Protection Agency (EPA) sample analysis results show that TMI site liquid effluents are in accordance with regulatory limits, hRC requirements, and the City of Lancaster Agreement.
THI water effluents are sampled froa the station (Units 1 and 2) discharge and analyzed by EPA. Gamma spectrum analyses of the seven daily composited samples for February 14 - 21, 1987 indicated no BI-2 related radioactivity.
.o EPA's ganaa spectrum analysis of the NRC's THI outdoor air sample for the period February 28 - March 6, 1987 showed no reactor related radioactivity.
The Lancaster water works intake composited seven daily samples February 15 - 21, 1987. The gaar.a spectrum analyzed by EPA showed no reactor related radioactivity.
3.
DECONTAMINATION ACTIVITIES Remote robotic scabbling of the seal injection valve room comenced during the w2ek as well as scabbling in the seal return cooler cubicle and the floor beneath the B and C bleed tanks.
Desludging of the auxiliary building sump and hands-on decontamination of the Westinghouse valve race continued.
Scabbling and vacuuming of the elevator shaf t roof was completed with painting scheduled for this week.
QiO$$ h500 0
n D ATE >
..t
NRC FORM 318 (10-80) NRCM 0240 OFFICIAL RECORD COPY
1 I
t Harold R. Denton 2
March 9, 1987 Frank J. Miraglia NRC/TMI-87-019 4.
MRC EVAL.UATIONS IN PROGRESS Technical Specification Change Request numbers 49 and 51 and the associated Recovery Operations Plan Change Requests 31 and-33..
Technical Specification Change Request 52, 55 and 55.
Solid Waste Facility Technical Evaluation Report.
Heavy Load Safety Evaluation Report, Revision 3.
Processed Water Disposition Proposal.
Safety Evaluation Report for Use of Plasma Arc Cutting Torch.
Tec;porary Reactor Vessel Filtration System Safety Evaluation Report, Revision 3.
Pressurizer Defueling Safety Evaluation Report.
Safety Evaluation Report for Defueling of the Core Support Assembly.
Waste Handling and Packaging Facility Technical Evaluation Report, Revtsion 6 was approved on March 5,1987.
Containment Air Control Envelope Technical Evaluation Report, Revision 7.
Coagulant Criticality Safety Evaluation Report.
Revisien 2 to the Sediment Transfer and Processing Safety Evaluation Report.
Seismic Evaluation for Modified Containment Penetration.
Organization Plan Change Request 14.
5.
MEETING The Advisory Panel for the Decontamination of Three Mile Island Unit 2 is scheduled to meet on March 25, 1987 from 6:00 PM to 10:00 PM at the Holiday Inn, 23 S. Second Street, Harrisburg, PA. The meeting will include further discussion of the proposed disposition of the accident-generated water and the NRC's Draft EIS and will include an opportunity for public coment.
Persons desiring to speak before the Panel are requested to contact Mr.
Thomas Smithgall at 717-291-1042, or write to him at 2123 Marietta Avenue, Lancaster, PA 17603, su that they may be placed on the meeting agenda.
ORIGINAL SIGNED BYs William D. Travers Williaa D. Travers Director TMI-2 Cleanup Project Directorate FFICE) su n"" >
.........1 N.C FORM 318 (10 80) NRCM 0240 OFFICIAL RECORD COPY
i --
-m y
.=
N_
7 c'%'
r
)
n s
e a-
,2.-
@qy e< <~
-~ Harold Rf Denton 3
~
Q.9
. Frank J.iMiraglia ~
March 9. 1987
.NRC/TMI-87-019
'5 4~
~,
INTERNAL ~ DISTRIBUTION-
- CENTRAL-FILE e?
- NRC PDR.
U J/C LOCAL-PDR a:
-EDO S
OGC EPA-r.? y '
.. DOE i
- g_
RI Regional Administrator en-'
RI Division Directors 6
Public; Affairs, RI-7"
. State Liaison, RI M-THI HQ r/f m>
THI-SITE r/f X
TMI-2 Project Section File-THI-1ResidentOffice(5)
TMICleanupProjectDirectorate(14) y 5
/#
Yi s
q-
. /W 4
m, 4
--.o, x,.
[
a.
f.
m
hV n
.:f
)
g
.: s
^
t.
bj: ~
A
, k,,,,,T,M,I,C,P, TMI,P,
" ice > TMICP "a"^"'> 8.C.o.oprJr.s..[,,e.c.oxg.i.1.1....
ATh.om....... F.
C OAT:>3/7./.87....... 3/,f,./.87.....
3./.*f./.87....... 3.../.8 7......
- wnc u nu ais oo soi nncu o2' OFFICIAL RECORD COPY