T Federal Emergency Management Agency

(*

I Washington, D.C. 20472 MAR-31987 MEMORANDlH EOR: Edward L. Jordan Director f /h{ 3 Division of Emergency Preparedness and Engineerity Response

. Of fice of Inspection and Enforcenent k

U. S.'Nuc r Regulatory Comtission FROM:

Assistant Associate Director Office of Natural and Technological Hazards Program SUBJECf:

Exercise Report of the April 25, 1986, Exercise of the Offsite Radiological Dmrgency Response Plans for the Haddam Neck Nuclear Power Plant Attached is a copy of the Haddan Neck exercise report of the April 25, 1986, joint exercise of the offsite radiological energency response plans (RERP) for-the Haddam Neck Nuclear Power Plant (NPP). his was a full participation exercise for the State of Connecticut and local jurisdictions. H e report dated February 19, 1987, was prepared by Region I of the Federal P.wrgency Management Agency (FEMA).

There were two deficiencies identified during the exercise. Areas requiring corrective action (ARCA) were also identified. A remedial exercise was held on May 28, 1986, and a copy of the renedial exercise report is attached.

Based on the results of the renedial exercise and the State's schedule of corrective actions submitted for the ARCAs, FEMA considers that offsite radio-logical emergency preparedness is adequate to provide reasoneble assurance that apprcpriate measures can be taken of fsite to protect the health and safety of the public living in the vicinity of the site in the event of a radiological emergency. Werefore, the 44 CFR 350 approval granted on October 4,1984, for the Haddam Neck NPP will remain in effect.

If you have any questions, please contact Mr. Robert S. Wilkerson, Chief, Technological Hazards Division, at 646-2861.

Attachments As Stated 8703120064 870303 PDR ADOCK 05000213 PDR p