ML20212M119
ML20212M119 | |
Person / Time | |
---|---|
Issue date: | 10/07/1999 |
From: | Vietticook A NRC OFFICE OF THE SECRETARY (SECY) |
To: | Travers W NRC OFFICE OF THE EXECUTIVE DIRECTOR FOR OPERATIONS (EDO) |
References | |
REF-10CFR9.7 SECY-99-219-C, NUDOCS 9910080171 | |
Download: ML20212M119 (3) | |
Text
,eoeeoeeoeeeeeeoeeeeeeen
!e RELEASED TO THE DDR !
3 po .,%'e, UNITED STATES 7' -
g NUCLEAR REGULATORY COMMISSih ,,,y y wAssinoToN.o.c. nosse. coo, j,,, , , , , , , , , [,
"o October 7, 1999
%,e,
- SECRETARY MEMORANDUM TO: William D. Travers Executive Director for Operations ,
FROM: Annette L. Vietti-Cook, Secretary
'DgN l j
SUBJECT:
STAFF REQUIREMENTS - SECY-99-219 - PROPOSED REVISION OF THE ENFORCEMENT POLICY TO ADDRESS THE PROCESS FOR ASSESSING THE SIGNIFICANCE OF VIOLATIONS -
The Commission has approved publication of the revised Enforcement Policy in the Federal Reaister. as described in SECY-99-219, subject to the following comments and attached revisions.
The staff should review the discussion related to announcing public meetings contained in the i FRN. While this informatica is currently accurate, some ongoing initiatives may soon cause this information to be outdated (e.g., electronic bulletin board may be eliminated). The staff should consider this in the FRN and provide the public with guidance (e.g., webpage) for where ,
additional information on revisions to the process for noticing public meetings, if approved, could be found. ,
As the staff continues its ongoing efforts to improve the reactor oversight process, the staff should seek internal and external stakeholder insights regarding how to further improve the NRC i Enforcement Policy including consideration of those process improvements that facilitate
' Regional implementation of the policy. The staff should ensure that the next revision to the enforcement policy is fully integrated with the revised reactor oversight process and completed on a schedule that supports implementation of the revised oversight process at all operating reactors.
Forward the press release via the normal review process prior to issuance.
Attachment:
As stated I
M ,
I p @S#1, Os+012 9910000171 991007 PDR 10CFR pg PT9.7
W 1
(. 2- )
cc: Chairman Dicus Commissioner Diaz Commissioner McGaffigan
- Commissioner Merrifield OGC CIO CFO OCA OlG l
'OPA l Office Directors, Regions, ACRS, ACNW, ASLBP (via E-Mail) !
PDR l DCS:
I i
)
s l
l
Note: Pages in the FRN were not numbered in SECY-99-219. Page number references have
. been added to ensure accuracy of the revisions.
s Page 4, 2ad and 6* lines: hyphenate " performance-based"
- d. Page 6, first full paragraph, 3'd line: change "should" to "will"
- c. Page 7,2"d line: change "should" to "will"
- d. Page 9,1" full sentence: add "either" after "not meant to eliminate" and change "nor" to "or"
- e. Page 18, Section Ill, " Responsibilities," first paragraph, 3'd line: delete " Regulatory Effectiveness"
- f. Page 26,Section VI, " Enforcement Actions," second paragraph: delete the sentence that states "For the vast majority of violations, a Notice of Violation or a Notice of Nonconformance is the normal action."
i Attachment