Text
_ _ _ _.
~..
../ ~ N
?
he Itg/
Er e gy operations,Inc.
Killona. LA 70006 Tel 504 739 6242 Early C. Ewing, lil ic ety & Regdawy Afan W3F1-97-0251 A4.05 i
PR Novembe-5,1997 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555
Subject:
Waterford 3 SF.S Docket No. 50-382 License No. NPF-38 Emergency Plan Implementing Procedures Gentlemen:
Enclosed are the latest issues of three recently revised Waterford 3 Emergency Plan Implementing Procedures. This submittalis being made in accordance with Appendix E of 10CFR50. These cnanges were reviewed in accordance with 10CFR50.54 requirements and were determined not to decrease the effectiveness of the emergency plan.
Included in this submittal are the following procedures:
1.
EP-002-100 (Revision 26), Technical Support Center (TSC) Activation, i
Operation and Deactivation. This revision involves TSC organization changes and administrative changes affecting transfer activities and addition of the Control Room Intercom Circuit
/
2.
EP-002-102 (Revision 25), Emergency Operations Facility (EOF) Activation, Operation and Deactivation. This revision involves EOF organization changes j
and administrative changes affecting transfer activities and addition of the h, /!g Contiol Room Intercom Circuit.
3.
EP-003-040 (Revision 20), Emergency Equipment Inventory. This revision provides clarification of existing requirements and adds guidance to ensure emergency equipme nt is inventoried.
(NOTE:
EP-002-100, Revision 26 and EP-002-102, Revision 25 contain changes which will be incorporated into the next revision of the
'pnq' Emergency Plan.)
~
H 9711070076 971105 PDR ADOCK 05000382 F
s..
Emergency Plan implementing Procedures W3F1-97-0251 Page 2 -
November 5,1997 Should you have any questions concerning these procedures, please contact J.J. Lewn, Emergency Planning Manager, at (504) 739-6624.
Very truly yours, E.C. Ewing Director Nuc' ear Safety & Regulatory Affairs ECE/ssf Enclosures cc:
(w/ Enclosures)
E.W. Merschoff, NRC Region IV (2 copies)
(w/o Enclosures)
C.P. Patel (NRC-NRR)
G.M. Good (NRC Region IV)
J. Smith N.S. Reynolds NRC Resident inspectors Office k