Columbus,01143210 Collegeof Engineering 2070 Neil Avenue Phone 614-292-2836 FAX # 614-292-3244 UNIVERSITY September 16,1999 Document Control Desk Nuclear Regulatory Commission Washington DC 20555
Dear Sir:
Please find enclosed the annual report for The Ohio State University Research Reactor, Docket No. 50-150. This report is being submitted as required by our Technical Specifications. Section 6.6.1. If you have questions on the content of this report, please contact Mr. Richard Myser, Associate Director of the Nuclear Reactor Laboratory.
Sincerely.
David B. Ashi.-
Dean, College of Engineering and The John C. Geupel Chair in Civil Engineering DBA:nik Enclosure C: Nuclear Regulatory Commission Region 111 (w/ene)
Theodore S. Michaels (w/ene.)
Don W. Miller (w/ene.)
1 OQ j
9909270124 990630 PDR ADCCK 05000150 R
PDR J
f-l..,..
I THE OHIO STATE UNIVERSITY RESEARCH REACTOR ANNUAL REPORT FOR FY 98/99 SEPTEMBER 16,1999 l
l l
l l
l l
1 i
J
l.
t I
l
' Introduction As stated in The Ohio State University Research Reactor Technical Specifications, Section 6.6.1 Operating Reports, j
an annual report shall be made to the NRC by September 30 of each year. This report is to include the following seven sections.
1.
A narrative summary of operatmg expenence (includmg expenments performed) and of changes in l
facility design, performance characteristics, and operating procedures related to reactor safety occurring during the reporting period.
2.
A tabulation showing the energy generated by the reactor (in Kilowatt hours) and the number of I
hours the teactor was in use.
l 3.
The results of safety-related maintenance and inspection. The reasons for corrective maintenance of safety-related items shall be included.
l 4.
A table of unscheduled shutdowns and inadvertent scrams, including their reasons and the corrective actions taken.
5.
A summary of changes to the facility or procedures, which affect reactor safety and performance of l
tests or experiments carried out under the conditions of sections 50.59 of 10CRF50.
6.
A summary of the nature and amount of radioactive gaseous, liquids, and solid efTluents released or discharged to the environs beyond the effective control of the licensee as measured or calculated at or prior to the point of such release or discharge.
7.
A summary of radiation exposures received by facility personnel and visitors, including the dates and times of significant exposures.
These seven sections are discussed below. These are all for the period July 1,1998 through June 30,1999, except as noted for exposure records.
l. A.
Experiments Performed l
The staff of The OSU Research Reactor are generally involved in four types of experiments at the Nuclear l
Reactor Laboratory. Included are introductions to nuclear research, neutron activation analysis, material irradiations, and classes that measure various reactor parameters. Typically when we introduce students.
faculty or other experimenters to nuclear research, we do the following:
a.
Discuss nuclear reactions and radiological safety.
l b.
Operate the reactor at 10kW-100kW c.
Have the individuals observe control room operations.
d.
Complete a tour and demonstrate irradiation techniques.
Neutron activation analysis experiments are routinely completed for students ranging from high school to l
graduate school. The facilities normally utilized are the " rabbit" (pneumatic tube) and the "CIF" (Central Irradiation Facility). Much of the NAA work is geological samples.
t l
l OSURR Annual Report Page1of5 9/99
i l
, Material irradiations, other than for NAA, are in four basic areas: isotope production; detector, electronic component and fiber optic testing; boron neutron capture therapy (BNCT); and irradiation of biological samples. Isotope production is done often for medical research. Detector and electronic component testing l
is done routinely. This testing is usually completed in the thermal column, or one of the beam ports, while j
fission chamber testing is in the Central Irradiation Facility. The reactor thermal column is also utilized for i
other BNCT studies. Typically it is the location for cell samples to determine their boron content.
l Various nuclear engineering or physics classes throughout Ohio utilize the reactor for the following basic experiments:
l a.
Approach to critical (using banked control rods rather than fuel loading).
b.
Control rod calibration by rod drop, positive period, and subcritical multip!' cation.
c.
Measurement of the Reactor Transfer function.
d.
Void coefficient measurements, i
l e.
Radiological surveys.
The reactor utilization for July 1,1998 through June 30,1999 is summarized in the following reports.
Funding for colleges and universities (other than OSU) that utilize the OSU Research Reactor is provided in part by the DOE funded Reactor Sharing Program.
l l
l I
I 3
OSURR Annual Report Page 2 of 5 9/99
e j
(
(:
I l
Utilization Report for the i
Ohio State University Nuclear Reactor Lab July 1 December 31,1998 I.
Reactor Utilization User Activity Hours Miami University Na and Hf production 5
i EPRl/OSU NE Evaluation of power monitors 10 l
OSU NE
.744,505,606 Labs 23 i.
Kent State University '
Neutron damage of Mgo crystals -
30 l
Wittenberg University NAA 4
OSU Pathology / NE BNCT 18 Air Force Institute of Approach to critical and control rod 4
i Technology calibrations t
Cleveland Clinic Re production 18 Reuter-Stokes fission chamber testing 86 l
Misc.
Tours and demonstrations 12 OSU Nuclear Reactor Annual core calibration -
12 Laboratory l
EPRI / OSU NE Fiber optics irradiations 8
l Total 230 l
January 1 - June 30,1999 User Activity Hours Reuter-Stokes Fission chamber testing 30.
StyroChem NAA of plastic for Br 4
r l
OSU NE/ Pharmacy BNCT 1
l Cleveland Clinic Re production 22 OSU NE 744, 505,606 Labs 9
i Cincinnati Electronics Radiation Damage Study 1
l Wright State University NAA Lab I
l OSU Physics Radiation Damage Study 2
f Case Western Reserve NAA 7
l OSU NE Xenon feedback 35 i
Miami University Hfproduction iJ Misc.
Tours and demonstrations 12 Total 134
!i-
- 1. H.
Changes in Facility Design There were no facility design changes that required a change to the Technical Specifications. 10CFR50.59 changes are described in section 5. A.
1.C.
Changes in Performance Characteristics There have been no changes in performance characteiistics related to reactor safety in the last year.
1.D.
Changes in Operating Procedures There were no changes in operating procedures related to reactor safety in the last year (10 CFR50.59 1
changes are described in section 5 B.).
OSURR Annual Report Page 3 of 5 9.'99 J
.,2.A.
, Kilowatt-Hours of Operation - 66,560
- 2. H.
Hours of Utilization - 364.
3.
Safety Related Maintenance -
None 4.
Unscheduled Shutdowns From July 1,1998 to June 30,1999 there were four unplanned shutdowns. These are summarized below.
Reason Corrective Action Failure to index linear level meter (1)
Discussed with operator Magnet current amplifier (3)
Magnet current amp module Adjusted
- 5.
Changes in Facility Procedures and Performance of Tests or Experiments in Accordance with 10CFR50.59 A. During the period July 1,1998 to June 30,1999, no OSURR Modification Requests were completed by the reactor staff and reviewed by the Reactor Operations Committee.
B. The following is a list of procedure changes made under 10CFR50.59 from July 1,1998 to June 30, 1999 in accordance with Administrative Procedure AP-05, entitled Format for Writing, Revising, and Approving Procedures.
Procedure Procedure Revision Number Title '
Date RS-02 Radioactive Waste Disposal 1/29/99 l
l RS-08 NRL Smear Survey 1/29/99 RS Il Routine Shipment of Radioactive Materials -
7/1/98 RS-17 Ar-41 Release Calculations 9/30/98 IM-04 Post-Shutdown Checkout 7/15/98 SP-02 Security Call List -
8/12/98 IM-12 F cactor Instrumentation Calibration / Checks 8/28/98 l
6.
Radioactive Effluents A. Gaseous Efiluent - The only emuent we measure is the release of Ar-41. For the period July 1 Dec.
31,1998, Ar-41 releases measured 1.83% of the annual average concentration limit. From Jan.1 -
June 30,1999, releases measured 1.90% of the annual average concentration limit.
In accordance with the requirements of 10CFR20.1101(d), the COMPLY code was run using the total l
Ar-41 release for the period Julyl,1998 June 30,1999 of 277.3 mci. Using level 2 in the code the effective dose ec,nivalent rate at the facility fence was computed to be 0.2 mrent'yr. This is well below LSe 10 mrem /yr constraint specified in the regulation.
B. Liquid Releases - Hot sink releases are recorded and reported through the OSU Office of Radiation Safety. Releases from the reactor pool to the sanitary sewer were not made.
3 C. No releases of solid radioactive material were made to the uncontrolled environment.
l l
OSURR Annual Report Page 4 of 5 9/99
7.
Radiation Exposures
' Since the firm that maintains records for The Ohio State University keeps a year to date record, it is easier to report this by the nearest completed calendar year. Therefore film badge exposures in this report are for the period January 1,1998 to December 31,1998. Four individuals were monitored as radiation workers for the entire year or a major part ofit. These are tabulated below. They are consistent with the ALARA policy for The Ohio State University and represent a fraction of allowed limits. All doses are in rem.
Individual DDE LDE SDE WB SDE, ME TEDE I
0.160 0.160 0.340 0.370 0.160 2
0.110 0.110 0.110 0.340 0.110 3
0.090 0.090 0.090 0.690 0.090 4
0.040 0.040 0.040 0.120 0.040 OSURR Annual Report Page 5 of 5 9/99
.-