Amend 122 to License NPF-57,revising TS Limiting Condition for Operation 3.7.3 & TS Table 3.7.3-1.Changes Modify Flood Protection Actions Required When Severe Storm Warnings That May Effect Site in Effect
ML20212C118
Person / Time
Site: Hope Creek 
Issue date: 09/17/1999
From: Clifford J
NRC (Affiliation Not Assigned)
To:
Shared Package
ML20212C120 List:
References
NUDOCS 9909210147
Download: ML20212C118 (5)


Text

.-

88'4g lt UNITED STATES y.

7 D'

E NUCLEAR REGULATORY COMMISSION 1

E WASHINGTON, D.C. 20555 0001

-**.. /

s PUBLIC SERVICE ELECTRIC & GAS COMPANY ATLANTIC CITY ELECTRIC COMPANY DOCKET NO. 50-354 HOPE CREEK GENERATING STATION AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.122 License No. NPF 57 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment filed by the Public Service Electric & Gas Company (PSE&G) dated December 30,1998, as supplemented September 13, 1999, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rulerand regulations of the Commission; C.

There is reasonable assurance: (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations set forth in 10 CFR Chapter I; i

D.'

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as

. indicated in the attachmentjo this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-57 is hereby amended to read as follows:

9909210147 990917 PDR ADOCK 05000354 P

PDR

(2)

Technical Soecifications and Environmental Protection Plan The Technical Specifications contained in Appendix A, as revised through Amendment No.122, and the Environmental Protection Plan contained in Appendix B, are hereby incorporated into the license. PSE&G shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

t 3.

The license amendment is effective as of its date of issuance, and shall be implemented within 60 days.

FOR THE NUCLEAR REGULATORY COMMISSION auM.0l/d J mes W. Clifford, Chief, Section 2 1

Project Directorate i Division of tJcensing Project Management Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance:

September 17, 1999 l

-r -

ATTACHMENT TO LICENSE AMENDMENT NO.122 FACILITY OPERATING LICENSE NO. NPF 57 DOCKET NO. 50-354 Replace the following pages of the Appendix "A" Technical Specifications with the attached 1

revised pages. The revised pages are identified by Amendment number and contain marginal I

lines indicating the area of change.

i Remove lasert 3/4 7-9 3/4 7-9 3/4 7-10 3/4 7-10 l

l

,o

rm t

' PLANT SYSTEMS 3/4.7.3 FLOOD PROTECTION LIMITING CONDITION FOR OPERATION

==================================================================

3.7.3 Flood protection shall be provided for all safety related systems, components and structures when the water level of the Delaware River reaches 6.0 feet Mean Sea Level (MSL) USGS datum (95.0 feet PSE&G datum) at the Service Water Intake Structure.

APPLICABILITY: At all times.

ACTION:

a.

With severe storm warnings from the National Weather Service which may impact Artificial Island in effect or with the water level at the service water intake structure above elevation 6.0 feet MSL USGS datum (95.0 feet PSE&G datum), initiate and complete:

1.

The closing of all service water intake structure watertight perimeter flood doors identified in Table 3.7.3-1 within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />, or declare affected service water system components inoperable and take the actions required by LCO 3.7.1.2;

- and -

2.

The closing of all power block watertight perimeter flood doors identified in Table 3.7.3-1 within 1.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br />.

Otherwise, be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in' COLD SHUTDOWN within the following 21 hours2.430556e-4 days <br />0.00583 hours <br />3.472222e-5 weeks <br />7.9905e-6 months <br />. Once closed, all access through the doors shall be administratively controlled.

b.

With the water level at the service water intake structure above elevation 10.5 feet MSL USGS datum (99.5 feet PSE&G datum), be in at i

l laast HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTDOWN within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

SURVEILLANCE REQUIREMENTS

============================================.2=====================

l 4.7'.3 The water level at the service water intake structure shall be I

. determined to be within the limit by:

a.

Measurement at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the water level is below elevation 6.0 MSL USGS datum (95.0 feet PSE&G datum), and b.

Measurement at least once pr* 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> when severe storm warnings from the National Weather Service which may impact Artificial Island are in effect.

c.

Measurement at least once per hour when the water level is equal to or above elevation 6.0 MSL USGS datum (95.0 feet PSE&G datum).

HOPE CREEK 3/4 7-9 Amendment No. 122

p.

TABLE 3.7.3-1 PERIMETER FLOOD DOORS

' ItTTAKE STRUCTURE DOORS Water tight coor 1 Water tight door 3 Water tight door 6 Hater tight door 8 POWER BLOCK DOORS and HATCH

' Doors & Hatch Location Hatch Exterior 45; K S 45.5; L 3340B 44; M 3337B 44; Md 6312 45.4; T 6323B 45.4; U 5315A 29.9; X 5315C 29; X 4323A 13.6; U 4304 13.6; U 3301A 13.6; Md 3305B 13.6; L

=

3315B Interior-102' 25; H 3329A 27; H 3331B 35; H 3209A Interior 26; H v,

.a

{

HOPE CREEK 3/4 7-10 Amendment No. 122 m-