Text
TENNESSEE VALLEY AUTHORITY CHATTANOOGA. TENNESSEE 374ol SN IS7B Lookout Place JUN 271986 U.S. Nuclear Regulatory Commission Region II a
ATTN:
Dr. J. Nelson Grace, Regional Administrator 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 cm
Dear Dr. Grace:
c-SEQUOYAH NUCLEAR PLANT UNITS 1 AND 2 - NRC-OIE REGION II INSPECTION REPORT 50-327/86-11 AND 50-328/86-11 The statement, " Discussion with responsible licensee personnel resulted in a commitment being made that three months after both units (1 and 2) are returned to operation, the Q-list will be implemented.," was documented in item 7.d of the subject report.
By this letter TVA is committing to the following revision of the above statement, "... after both units (1 and 2) are returned to operation, a schedule or plan will be developed to implement the Q-list.
If you have any questions, please get in touch with R.
E. Alsup at FTS 858-2725.
To the best of my knowledge, I declare the statements contained herein are complete and true.
Very truly yours, TEN ES EE EY AUTHORITY R. Gridley, Di ctor Nuclear Safety and Licensing cc:
Mr. James Taylor, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Mr. S. P. Weise, Chief Reactor Projects Branch 1 Division of Reactor Projects U.S. Nuclear Regulatory Commission Region II - Suite 2900 101 Marietta Street, NW Atlanta, Georgia 30323 h
G An Equal Opportunity Employer l