Summary of 970702-03 Meeting W/Siemens Ag Power Generation Group in Rockville,Md to Provide Background Info on Vendor Capability to Support Industry/Erpi Program for Qualification of Programmable Logic Controllers
ML20211Q081
Person / Time
Issue date: 10/15/1997
From: Wang E
NRC (Affiliation Not Assigned)
To: Essig T
NRC (Affiliation Not Assigned)
References
NUDOCS 9710220089
Download: ML20211Q081 (10)


Text

,

Ct:0 4

JNITED STATES y

g

,j NUCLEAR REGULATORY COMMISSION WASHINGTON. D.C. 300 4 4001 October 15, 1997 MEMORANDUM TO:

Thomas H. Essig, Acting Chief Generic issues and Environmental Projects Branch Division of Reactor Program Management, NRR FROM:

Egan Wang, Reactor Engineer Generic issues and Environmental Projects Branch b C! vision of Reactor Program Management, NRR

SUBJECT:

SUMMARY

OF MEETINGS HELD ON JULY 2 3,1997, WITH SIEMENS TO SUPPORT ELECTRIC POWER RESEARCH INSTITUTE (EPRI) PROGRAM FOR QUALIFICATION OF PROGRAMMABLE LOGIC CONTROLLERS On July 2 3,1997, the staff held a public meeting with Siemens AG, Pc,wer Generation Group (KWU) (referred to hereafter as Siemens) at NRC headquaters in Rockville, Maryland to provide background information on this vendor's capability to support the industry /EPRI initiative to qualify programmable logic controllers (PLCs) for use in safety systems at nuclear power plants. A list of attendees and their affiliations is provided as Attachment 1.

A copy of the presentation slides used by Siemens in its presentations is provided as.

At a meeting held on July 23,1996, EPRI described its proposal for a PLC qualification program and the rationale behind the initiative. EPRI and several member utilities have developed a three phase program for qualification of PLCs. Phase 1 of this program will be development of a guidance / requirements document containing the generic specifications needed to approve a PLC. Phase 2 encompasses the qualification aspect of this program and will result in a PLC available for procurement as safety related. Phase 3 is the plant-specific implementation portion of the PLC program. Phase 1 of this program is currently under NRC review.

As a result of utility interest in the possibilities of using Siemens PLC products in retrofit projects Sieniens requested a meeting to introduce their products to the staff and to discuss NRC review criteria.

Siemens believed that it would be useful for the staff to understand Siemens' capabilitles and experience. Siemens stated their intention to submit a topical report and request a NRC safety evaluation.

qp/v Siemens presented an overview of their product development process and their quality control process for both the hardware and software aspects of the design. They stated that they believe the standards and practices that they followed in the development and p

manufacturing process will allow them to be qualified as a 10 CFR 50 Appendix B vendor.

Wp m QN_w &yU m,

c

^

Mum Q,

i,w w w-C. C i/ M

\\

[ L ;M ' h,, ch 9710220099 971015 C

PDR TOPRP Er1VEXXN C

PDR

T. Essig 2

October 15, 1997 The review and acceptance criteria for a qaulity assurance program was discussed. Their products have been qualified for use in Germany Sy Technischer Oberwachungs Verein (TUV). The staff stated that they would become familiar with the TUV review methodologies and standards with the possibility of using the TUV tests and approvals to reduce the scope of the NRC review. The product development is primarily performed in the Sierr sns facilities in Germany. The Romell, Georgia facility may be used for assembly of the finalinstrumentation cabinets if any US plant purchases one of their systems. They listed their U.S. and international customers and described the type of non nuclear safety related systems and nuclear systems that they have provided. The products that Siemens is proposing for use in the nuclear power plant industry are the TELEPERM XS (for safety-related systems) and TELEPERM XP (for non safety related systems). Siemens described these systems as complete integrated instrumentation and control systems.

These systems include data communications and human-machine interfaces as well as PLCs. The staff discussed the use of Chapter 7 of the Standard Review Plan and the specific standards included. A significant discussion topic was the NRC position on diversity and defense-in-depth.

Attachments: As stated cc w/stts: Mr. H. Donald Curet, Manager Product Licensing Siemens Power Corporation 2101 Horn Rapid Road P.O. Box 130 Richland, Washington 99352-0130

T. Essig 2

October 15, 1997 The review and acceptance criteria for a qaulity assurance program was discussed. Their products have been qualified for use in Germany by Technischer Oberwachungs Verein

,(TUV). The staff stated that they would become familiar with the TUV review methodologies and standards with the possibiiity of using the TUV tests and approvals _to.

reduce the scope of the NRC review. The product development is primarily performed in

' the Siemens f acilities in Germany. The Roswell, Georgia f acility may be used for assembly of the finalinstrumentation cabinets d any US plant purchases one of their systems. They listed their U.S. and international customers and described the type of non nuclear safety

.releted systems and nuclear systems that they have provided. The products that Siemens +

is proposing for use in the nuclear power plant industry are the TELEPERM XS (for safety related systems) and TELEPERM XP (for non-safety related systems). Siemens'.

described these systems as complete integrated instrumentation and control systems.

These systems include data communications and humen machine interf aces as well as PLCs. The staff discussed the use of Chapter 7 of the Standard Review Plan and the specific standards included. A significant discussion topic was the NRC position on 1

/

diversity and defense in-depth.

Attachments: As stated i

~

cc w/atts: Mr. H. Donald Curet, Manager Product Licensing Siemens Power Corporation 2101 Horn Rapid Road P.O. Box 130 Richland, Washington 99352 0130 Distribution:

Hard Copy

/ entral File PUBLIC PGEB r/f C

ACRS OGC EWang E-Mail JRoe JStewart DSpaulding LCampbell DMatthews JGallagher JWermiel RGramm TEssig SBlack JMauck Document name: 970702-3. SUM 4 ri*See Previous Concurrence OFC PG E B,,,, 1 SC:PGE N

BC:HICB AC:PGEB e

<v f-NAME EWang:sw FAkstulewicz JWiemiel' TEssig 0 DATE 101/@ 97 10b97 1 10/7/97 10/16/97 OFFICIAL RECORD COPY II'

'I

__ws-.-_____

l Meeting with Siemens on July 2-3,1997 List of Attendees Name Organization Phone Number J. Stewart USNRC 301-415 2824 D. Spaulding USNRC 301 415 2928 P. Loeser USNRC 301-415 2825 J. Gallagher USNRC 301-415 3217 J. Joyce NRC 301 415 2842 J. Wermiel NRC 301-415 2821 J. Mauck NRC 301-415 3248 R. Gramm NRC L. Campbell NRC R. Druschel Siemene 49 69-807-3729 O. Schoerner Siemens 49 9131 18 85109 A. Graf Siemens 49-9131 18 6750 T. Ifran Siemens 770-5521295x141 H. Hofmann Siemens 49 9131-18 6430 J. Amin TU Electric 817 897-6469

SIEMENS Customer-Oriented Organization Managing Board Corporate Groups Departments Corporate Offices t '

l Power ~,

W ees Power Generation M eland hW Communicadone T N ond (KWU)

Building Systems Stenderd Products

-f.

I"'

Privet +

g,c,N and Puretie.si

, Automation Communicadon Communication Defence Electronice Human Repo:recos 1r-Networks Systeme l

j i

Transportetton 'h53,r Aueermodve

' Medical Economics and m A-4,4..sSystemep, ?.

Engineering T--','~"--

.f Corporate Reletions h

Systemas t

  • ,,f w

-- e e,

i

't --a.:. h

-I

?.

4

~

pyy:.$fsp;g

>lsetromechenleet Planning and.:s;.

tr*seekseture Componente'er' die E

Componente.

C; J_-A ;;

Services Electron Tub.na?fy=

es

. rswfi Separate Legal Units 1

Siemens Nixdorf Informationo-Oerem GmbH eysteme (SNI) l l

-W : :

1 3:enwwm v

Regional.orgen(Istion:.'ymaru l

iniemationalsionieneesmpenses e W oenese e esses sempsedse 'e mesomenesere adhese e egencies

+ ja y 8

...- :n,

Power Generation e KWU Q

1.3t

SIEMENS KWU Group Organization Group Executive Management Adolf Hatti(Chairman)

Dr.Hans B6hm - Andreas Kley Fossil Industrial Instrumen-Nuclear Nuclear Power Turbines and tation &

Power Fuel Cycle Generation industrial

Control, Generation (KWU B)

(KWU F)

Power Plants Power (KWU N)

(KWU FI)

Generation Helmut Gierse (KWU L)

Hydro Power Plants, New Technologies (KWU FR)

Wulf Barkle Werner Schr6 der Prof. Klaus Riedle Dr.Klaus Hassmann Norbert K6nig Eberhard Schomer Dr. David McAlces l

Sales Regions Business Administration (KWU K)

Andreas Kley Central Functions Related Subsidiaries international Cooperation Agreements Power Generation. KWU Q

SIEMENS Table of Contents O

Quality Policy of Siemens AG O

Quality Management Principles of Siemens KWU O

Quality Management System of Siemens KWU N O Quality System Documentation O Quality system certificates O Tasks and Responsibilities of Quality Departments O ProjectTeam Organization 1

O Project-related QM Planning l

O Design Control 0 ProcurementControl O Intemal Quality Audits O ManagementReviews QM System of KWU N

      • 0',, 7," " "
  • SIEMENS Siemens KWU Quality System El KWU has implemented a Quality System which complies with the following Codes and Standards as required by business needs:

O ISO 9001: 1994, Quality System - Model for Quality Assurance in Design / development, Production, Installation and Servicing O IAEA 50-C-OA, Code on the Safety of Nuclear Power Plants:QualityAssurance i

O KTA 1401, General requirements for Quality Assurance O 10 CFR50, App. B, Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants O ANSI /ASME NQA-1, Quality Assurance Program requirements for Nuclear Facilities O ASME 111, NCA 4000, Quality Assurance QM System of KWU N

""""J' "l"""'

SIEMENS Quality System Documentation

[3 The Quality System of KWU N is documented in 2 Quality Manuals and associated QM procedures O QMH 12 includes the procedures which are in compliance with

- ISO 9001: 1994

- IAEA 50-C-QA

- KTA 1401 l

l O QSH E 601 includes the procedures which are in compliance with

- 10 CFR 50, App. B

- ANSI /ASME NQA-1

- ASME Ili, NCA 4000 QM System of KWU N

[","l',7'""'*~

SIEMENS Quality System Certificates L

0 The official German certification organization TGV CERT has certified that KWU N has established and implemented a Quality System which fulfills the requirements of O DIN EN ISO 9001 O IAEA 50-C-QA O The German Association of Power Plant Operators (VGB) l has confirmed that the Quality System of KWU N also complies with the requirements of O KTA 1401 O Moreover Siemens KWU is holder of the following ASME stamps O N stamp O NPT stamp QM System of KWU N

,""*Z "*"" "

amu g

\\

UNITED STATES g

.}

NUCLEAR REGULATORY COMMISSION f

o WASHINGTON. o.C. seseHooi October 15, 1997 MEMORANDUM TO: - Thomas H. Essig, Acting Chief Generic lasues and Environmental Projects Branch Division of Reactor Program Management, NRR -

FROM:

Egan Wang, Reactor Engineer

-t Generic issues and Environmental Projects Branch Division of Reactor Program Management, NRR

SUBJECT:

SUMMARY

OF MEETINGS HELD ON JULY 2 3,1997, WITH SIEMENS TO SUPPORT ELECTRIC POWER RESEARCH INSTITUTE (EPRI) PROGRAM FOR QUAllFICATION OF PROGRAMMABLE LOGIC CONTROLLERS On July 2 3,1997, the staff held a public meeting with Siemens AG, Power Generation Group (KWU) (referred to hereafter as Siemens) at NRC Seedquaters in Rockville, Maryland to provide background information on this vendor's capcJity to support the industry /EPRI initiative to qualify programmable logic controllers (PLCs) for use in safety sy*%ms at nuclear power plants. A list of attendees and their affiliations is provided as c.ttachment 1.

A copy of the presentation slides used by Siemens in its presentations is provided as.

At a meeting held on July 23,1996, EPRI described its proposal for a PLC qualification program and the rationale behind the initiative. EPRI and several member utilities have developed a three-phase program for qualification of PLCs. Phase 1 of this program will be development of a guidance / requirements _ document containing _the generic specifications

- needed to approve a PLC. Phase 2 encompasses the qualification aspect of this program and will result in a PLC available for procurement as safety-related. Phase 3 is the plant-

- specific implementation portion of the PLC program. Phase 1 of this program is currently under NRC review.

As a result of utility l'nterest in the possibilities of using Siemens PLC products in retrofit projects Siemens requested a meeting to introduce their products to the staff and to discuss NRC review criteria.

Siemens believed that it would be useful for_the staff to understand Siemens' capabilities and experience. Siemens stated their intention to submit a topical report and request a NRC safety evaluation.

Siemens presented an overview of their product development process and their quality conpu' process for both the hardware and software aspects of the design. They stated that they believe the standards and practices that they followed in the development and manufacturing process will allow them to be qualified as a 10'CFR 50 Appendix B vendor.

Q'VD12%0 0 E T -

T. Essig 2

October 15, 1997 The review and acceptance criteria for a qaulity assurance program was discussed. Their products have been qualified for use in Germany by Technischer Oberwachungs Verein (TUV). The staff stated that they would become f amiliar with the TUV review methodologies and standards with the possibility of using the TUV tests and approvals to reduce the scope of the NRC review. The product development is primarily performed in the Siemens f acilities in Germany. The Roswell, Georgia f acility may be used for assembly of the finalinstrumentation cabinets if any US plant purchases one of their systems. They listed their U.S. und international customers and described the type of non nuclear safety related systems and nuclear systems that they have provided. The produ::ts that Siemens is proposing for use in the nuclear power plant industry are the TELEPERM XS (for safety related systems) and TELEPERM XP (for non safety related systems). Siemens described these systems as complete integrated instrumentation and control systems.

These systems include data communications and human-machine interfaces as well as PLCs. The staff discussed the use of Chapter 7 of the Standard Review Plan and the specific standards included. A significant discussion topic was the NRC position on diversity and defense-in-depth.

Attachments: As stated cc w/atts: Mr. H. Donald Curet, Manager Product Licensing Siemens Power Corporation 2101 Horn Rapid Road P.O. Box 130 Richland, Washington 99352 0130 s

L E

T. Essig 2

Cetober 15, 1997 The review and acceptance criteria for a 'qaulity assurance program was discussed. Their products have been qualified for use in Germany by Technischer Oberwachungs Verein (TUV). The staff stated that they would become f amiliar with the TUV review methodologies and standards with the possibility of using the TUV tests and approvals to reduce the scope of the NRC review. The product development is primarily performed in the Siemens f acilities in Germany. The Roswell, Georgia facility may be used for assembly of the finalinstrumentation cabinets if any US plant purchases one of their systems. They listed their U.S. and international customers and described the type of non nuclear safety related systems and nuclear systems that they have provided. The products that Siemens is propcsing for use in the nuclear power plant industry are the TELEPERM XS (for safsty-related systems) and TELEPERM XP (for non safety related systems). Siemens described these systems as complete integrated instrumentation and control systems.

These systems ir.clude data communications and human-machine interfaces as well as PLCs. The staff discussed the use of Chrpter 7 of the Standard Review Plan and the specific standards included. A significant iiscussion topic was the NRC position on 1

diversity and defense-in-depth.

Attachments: As stated cc w/atts: Mr. H. Donald Curet, Manager Product Licensing Siemens Power Corporation 2101 Horn Rapid Road P.O. Box 130 Richland, Washington 99352 0130 Distribution:

Hard. Copy Central File iUBLIC PGEB r/f ACRS OGC EWang E-Mail JRoe JStewart DSpaulding LCampbell DMatthews JGallagher JWermiel RGramm TEssig SBlack JMauck Document name: 970702 3. SUM 4 NSee Previous Concurrence OFC PGEBr, 1 SC:PGEh BC:HICB AC:PGEB w

/ 'J TEssig[dVI s

NAME EWang:sw FAkstuiewicz JWiemiel' 101/ (/97 10b97 10/7/97 10/16/97 t

DATE OFFICIAL RECORD COPY

u Meeting with Siemens on July 2 3,1997 List of Attendees 4

i Name Organization Phone Number J. Stewart USNRC 301-415 2824 4

4 D. Spaulding USNRC 301-415-2928 P. Loeser USNRC 301-415 2825 J. Gallagher USNRC 301-415-3217 J. Joyce NRC 301-415 2842 J. Wermiel NRC 301-415 2821 J. Mauck NRC 301-415-3248 R. Gramm NRC L. Campbell NRC 3

R. Druschel Siemens 40 69-807 3729 O. Schoerner Siemens 49 9131-18 85109 A. Graf Siemens 49 9131-18 6750 T. ifran Siemens 770-552-1295x141 H. Hofmann Siemens 49 9131 18 6430 J. Amin TU Electric 817 897-6469

SIEMENS Customer-Oriented Organization i

Managing Board Corporate Groups Departments Corporate Offices I

Power Generation b'

TN W Corporate Industriel and Drives smd (KWU)

Building Systems Stenderd Producte v,

Communicatione

-11 boblic -- +y.

Privet"

'{~

PWesi"8 and

, Automation Communicadon Communication Defence Electronics Human Repoveces M'

Networte gg l

Systeme Economics and Transportodon /

Automotive Medical h'

T%

Systemos,.; q ?

Systems:,.

Engineering Corporate Relatione

.a 3 pf'.Q;)l}R M :* *.c:., 3

  • j "lectromeehenical E

Planning and

,4 Ireestructure Componente'evid.e Electron Tu,b..,esM,$-.

pf-Separate Legal Units Components C;._"_-;-- a.a W

t

.m Siemens Nixdorf I

Informationo-Oorem GmbH systeme (SNI) 7,,';,.

I qHGigp;%'.~?

v y.g 4 -

Regionalorgenbation:g ; -4,ggg.

i

. Intemedonet siemene companies. regiones estese e esses semindee '. empeemeneesve eIIIees. egene

a. v v

r-Power Generation. KWU Q-1.3(

(

SIEMENS KWU Group Organization Group Executive Management Adolf H6tti(Chairman)

  • Dr.Hans Bohm - Andreas Kley Fossil industrial Instrumen-Nuclear Nuclear Power Turbines and tation &

Fower Fue! Cycle Generation industrial

Control, Generation (KWU B)

(KWU F)

Power Plants Power (KWU N)

(KWU FI)

Generation Helmut Gierse (KWU L)

Hydro Power Plants, New Technologies (KWU FR)

Wulf Barkle Werner Schr6 der Prof. Klaus Riedle Dr. Klaus Hassmann Norbert K6nig Eberhard Schomer Dr. David McAlees Sales Regions Business Administration (KWU K)

Andreas Kley Central Functions i

Related Subsidiaries International Cooperation Agreements Power Generation. KWU Q

SIEMENS -

Table of Contents O

Quality' Policy of Siemens AG O

Quality Management Principles of Siemens KWU O

Quality Management System of Siemens KWU N O Quality System Documentation O Quality system certificates O Tasks and Responsibilities of Quality Departments O ProjectTeam Organization O Prc'2ct-related QM Planning O Design Control O ProcurementControl O intemalQuality Audits O ManagementReviews QM System of KWU N

"""2' '.,"" " "*

SIEMENS Siemens KWU Quality System O KWU has implemented a Quality System which cornplies with the following Codes and Standards as required by business needs:

O ISO 9001: 1994, Quality System - Model for Quality Assurance in Design / development, Production, installation and Servicing O IAEA 50-C-QA, Code on the Safety of Nuclear Power Plants:QualityAssurance 1

O KTA 1401, General requirements for Quality Assurance O 10 CFR50, App. B, Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants l

O ANSI /ASME NQA-1, Quality Assurance Program requirements for Nuclear Facilities O ASME 111, NCA 4000, Quality Assurance QM System of KWU N

~

SIEMENS Quality System Documentation O The Quality System of KWU N is documented in 2 Quality Manuals and associated QM procedures O QMH 12 includes the procedures which are in compliance with

- ISO 9001: 1994

- IAEA 50-C-QA

- KTA 1401 O QSH E 601 includes the procedures which are in compliance with

- 10 CFR 50, App. B

- ANSI /ASME NOA-1

- ASME 111, NCA 4000 l

" " ' ' " " " ~

OM System of KWU N

,", ""ll',,

...=. -. -. -...

SIEMENS Quality System Certificates i

O The official German certification organization TOV CERT

(

i-has certified that KWU N has established and implemented a Quality System which fulfills the requirements of l

O DIN EN ISO 9001

{

O IAEA 50-C-QA I

O The German Association of Power Plant Operators (VGB) has confirmed that the Quality System of KWU N i

also complies with the requirements of O KTA 1401 i

l 0 Moreover Siemens KWU is holder of the following.wSME stamps 4

O N stamp O NPTstamp I

QM System of KWU N

,7",, ",""" "

j

-