- _ _ _-_____- -____ __ __ -_- _

Director, Office of Resource Management November Monthly Operating Report Page 1 ATTACHMENT I AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.: 50/395 UNIT:

V. C. SUM 4ER I b

DATE:

12/12/86 COMPLETED BY:

G. A. LOIGNON TELEPHONE:

(803) 345-5209 NOVEMBER 1986

[

DAY AVERAGE DAILY POWER DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

LEVEL (MWe-Net) 1.

883 17.

879 2.

885 18.

879 3.

884 19.

879 4.

885 20.

879 5.

885 21.

878 6.

886 22.

880 7.

728 23.

880 8.

39 24.

880 9.

107 25.

879 10.

705 26.

879 11.

877 27.

880 12.

877 28.

882 13.

877 29.

880 14.

877 30.

880 15.

877 16.

878

(( Uk00!k 500 5

/

N\\


___--------_-----_-_-__----u

I Director Office of Resource Management November Monthly Operating Report Page 2 ATTACHMENT II OPERATING DATA REPORT DOCKET NO.:

50/395 UNIT:

V. C. SUMER I t

DATE:

12/12/86 COMPLETED BY:

G. A. LOIGNON TELEPHONE:

(803) 345-5209 OPERATING STATUS 1.

Reporting Period:

November 1986 l

Gross Hours in Reporting Period:

720 2.

CurrentlyAuthorizedPowerLevel(MWt): 2775 Max. Depend. Capacity (MWe-Net):

885 i

Design Electrical Rating (MWe_ Net):

900 3.

PowerLeveltoWhichRestricted(IfAny)(MWe-Net): N/A i

4.

Reasons for Restrictions: N/A THIS MONTH YR TO DATE CUMULATIVE 5.

Number of Hours Reactor Critical 720.0 7739.2 19732.5 6.

Reactor Reserve Shutdown Hours 0.0 0.0 0.0 7.

Hours Generator on Line 692.7 7643.5 19283.8 8.

Unit Reserve Shutdown Hours 0.0 0.0 0.0

)

9.

GrossThermalEnergyGenerated(MWH) 1,862,802 20,711,934 50,549,500

10. Gross Electrical Energy (MWH) 613,450 6,872,180 16,802,839 11.NetElectricalEnergyGenerated(MWH) 587,106 6,581,818 16,004,456
12. Reactor Service Factor 100.0 96.5 77.2
13. Reactor Availability Factor 100.0 96.5 77.2
14. Unit Service Factor 96.2 95.4 75.4
15. Unit Availability Factor 96.2 95.4 75.4 16.UnitCapacityFactor(UsingMDC) 92.1 92.8 70.8 17.UnitCapacityFactor(DesignMWe) 90.6 91.2 69.6
18. Unit Forced Outage Rate 3.8 4.6 6.9
19. Shutdowns Scheduled Over Next 6 Months (Type, Date & Duration of Each):

REFUELING, MARCH 6, 1987, 60 DAIS

20. If Shut Down at End of Report Period, Estimated Date of Startup: N/A 21.UnitsinTestStatus(PriortoCommercialOperation): N/A i

-' + -

r r-er--

w-

,-,., - - - -, -.---em

,.,,,. e ne-,orn---

,---+,n-,,,

-.,-,,w-w

,--w

,e

---wee.,wn,--g

~~~m>,

-.-m-m.-

m m -g

Director, Office of Resource Management November Monthly Operating Report Page 3 ATTACHMENT III UNIT SHUIDOWNS AND POWER REDUCTIONS i

DOCKET NO.: 50/395 UNIT:

V. C. SUMER I DATE:

12/12/86 COMPLETED BY:

G. A. LOIGNON TELEPHONE:

(803) 345-5209 NOVEMBER 1986 Method of TYPE Shutting F or S Duration Down the Corrective Actions /

No.

Date Reason Forced or (Hours)

Reactor or Comments Scheduled Reducing Power i

Maintenance Required on Feedwater Control Valves.

9 861110 F

27.3 A

1 Generator offline 27.3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br />. Reactor remained critical.

1 l

1

Director Office of Resource Management November Monthly Operating Report Page 4 ATTACHMENT IV NARRATIVE 5UMMARY OF OPERATIhG EXPERIENCE DOCKET NO.:

50/395 UNIT:

V. C. SUMMER I' DATE:

12/12/86 COMPLETED BY:

G. A. LOIGNON TELEPHONE:

(803) 345-5209 NOVEMBER 1986 On November 1, 1986, the plant was operating at approximately 100 percent power.

On November 7, power was reduced to perform repairs on the feedwater control valves.

The generator was offline from 0723 on November 8 to 1041 on November 9, while the reactor was held at 2 percent power. The plant returned to 100 percent power on November 10, at 1702 hours0.0197 days <br />0.473 hours <br />0.00281 weeks <br />6.47611e-4 months <br />.

On November 30, 1986, the plant was operating at approximately 100 percent power.

l l

l l

l

Nn Control Copy No.

M OFFSITE DOSE CAIC(IATION MANIAL ET)R SOUTH CAROLINA ELECTRIC AND GAS 000fANY VIRGIL C. SIMER NUCLEAR STATION REVISION 8 j

Septenber 1986 1

i l

i e

a Revision 8 l

i

LIST OF EFFECTIVE PAGES g

Revision Page' Revision i

8 1.0-1 5

11 8

1.0-2 5

iii 8

1.0-3 5

iv 5

1.0-4 5

v 5

1.0-5 5

vi 5

1.0-6 5

vii 5

1.0-7 5

viii 5

1.0-8 5

1.0-9 5

1.0-10 5

l 1.0-11 5

1.0-12 5

1.0-13 7

1.0-14 5

1.0-15 5

1.0-16 5

1.0-17 5

1.0-18 5

1.0-19 5

1.0-20 5

1.0-21 5

1.0-22 5

1.0-23 5

1.0-24 5

1.0-25 5

l 1.0-26 5

1.0-27 5

1.0-28 7

i 1.0-29 5

1.0-30 5

1.0-31 5

1.0-32 5

l.0-33 5

1.0-34 7

i 1.0-35 5

1.0-36 5

1.0-37 5

j l

1.0-38 5

1.0-39 5

1.0-40 6

l l

l ODCN, V.C. Staner/SCEandG: Revision 8 (fpetember, 1986) i l

l i

LIST CF EFFECTIVE PAGES (Cbntinued) g Revision Page Revision

. 2. 0.-l 5

2.0-46 5

2.0-2 5

2.0-47 5

2.0-3 5

2.0-48 5

2.0-4 5

2.0-49 5

2.0-5 5

2.0-50 5

2.0-6 5

2.0-51 6

2.0-7 5

2.0-u 5

2.0-9 5

3.0-1 5

2.0-10 5

3.0-2 5

2.0-11 7

3.0-3 5

2.0-12 5

3.0-4 5

2.0-13 5

3.0-5 8

2.0-14 5

3.0-6 5

2.0-15 5

3.0-7 5

2.0-16 5

3.0-8 5

2.0-17 5

3.0-9 5

2.0-18 5

3.0-10 5

2.0-19 5

3.0-11 5

2.0-20 5

3.0-12 5

2.0-21 5

3.0-13 5

2.0-22 5

2.0-23 5

2.0-24 5

2.0-25 5

2.0-26 5

2.0-27 5

2.0-28 5

2.0-29 5

2.0-30 5

2.0-31 5

I 2.0-32 5

l 2.0-33 5

2.0-34 5

2.0-35 5

2.0-36 5

2.0-37 5

2.0-37a 5

2.0-38 5

2.0-39 5

2.U-40 5

2.0-41 5

2.0-42 5

2.0-43 5

2.0-44 5

2.0-45 5

ODN, V.C. Sununar/SCF4G: Revision 8 (September, 1986) 11

CONTROLLED COPY DISTRIBUPION Person Copy #

Director, Nuclear Plant Operations 1

Manager, CHP&EP 2

Manager, Nuclear Licensing 3

Associate Manager, Health Physics 4

Associate Manager, Corporate Health Physics 5

Associate Manager, Radiological Analytical Services 6

l Supervisor, Count mom 7

Manager, Support Services 8

mnager, Cperations 9

Assoc. Manager Regulatory Coupliance 10 V. C. Stener Doctanent Section 11 Manager ISBG 12 Associate Manager, Quality Assurance 13 Associate Manager, Envirormental Programs 14 l

l l

ODCN, V.C. Stmner/SCEandG: Revision 8 (Septenber 1986) lii

.p RADIOIOGICAL ENVIlO4 ENTAL MONFIORING PROGRAM VIRGIL Co SG9ER NUC[ EAR STATION TABLE 3.0-1 Sanple E@osure Pathway Criteria for Selection of Sanpling and Iocations Iomtions Type and Frequency and/or Sanple Sanple 14mber and Iomtion Collection Frequency (1)

Mi/Dir of Analysis AIRBORNE (Cont'd)

C) 8 Stations to be placed in 11 3.3 N special interest areas such 13 2.9 N!4f as mulation centers, nearby 15 2.5 SSW residences, schools and in 2 16 28.0 W or 3 areas to serve as 17 24.7 SE controls.

18 16.5 S 31 5.8 NIE WATERBORNE:

54 1.7 ENE IV.

Surface A) 1 Indicator sanple downstream Time composite 21 2.7 S9f Gansna isotopic inter to be taken at a locatior, sanples with (3,6) conthly with which allows for mixing and collection every quarterly cczn-dilution in the ultimate month. (5) posite (by receiving river.

location) to be analyzed for tritium.

I B) 1 Control sanple to be taken 22(3) 30.0 Nitt l

at a lomtion on the re-ceiving river, sufficiently far up-stream such that no effects of punped storage operation are anticipated.

i i

00m, V. C. Summer, SCEanct: Revision 8 (September, 1986) 3.0-5 8

f<

g om - --

mz-um 29218 Nuclear Operations SCE&G December 12, 1986 Director, Office of Resource Management U. S. Nuclear Regulatory Commission MNBB 7602 Washington, DC 20555 ATTN: Mr. Learned W. Barry

SUBJECT:

Virgil C. Summer Nuclear Station Docket No. 50/395 Operating License No. NPF-12 November Monthly Operating Report

Dear Mr. Barry:

Please find enclosed the November 1986 Monthly Operating Report for the Virgil C. Summer Nuclear Station Unit No. 1.

This submittal is made in accordance with the requirements of Technical Specification 6.9.1.10.

Please also find attached a copy of the latest changes to the Offsite Dose Calculation Manual.

If there are any questions, please call us at your convenience.

y truly yours, c ' t S }@vV/vv %

\\

9 Oc A. NAuW nb AM: GAL: DAN /bjh Attachments pc:

0. W. Dixon, Jr./T. C. Nichols, Jr.

R. M. Campbell, Jr.

E. H. Crews, Jr.

K. E. Nodland E. C. Roberts R. A. Stough

0. S. Braaham G. O. Percival J. G. Connelly, Jr.

R. L. Prevatte D. R. Moore J. B. Knotts, Jr.

W. A. Williams, Jr.

INP0 Records Center H. R. Denton ANI Library J. Nelson Grace L. N. Carter 1

Group Managers R. E. Rainear W. R. Baehr NPCF C. A. Price File C. L. Ligon (NSRC) i i

i

.-.. _.. - _ _. -. - _ _ _.. _.