Informs Commission That Staff Believes Technical Bases for 10CFR71.63 Remain Valid & That Provisions Provide Adequate Flexibility for Current & Future Technologies
ML20211L072
Person / Time
Issue date: 09/29/1997
From: Callan L
NRC OFFICE OF THE EXECUTIVE DIRECTOR FOR OPERATIONS (EDO)
To:
References
SECY-96-215-C, SECY-97-218, SECY-97-218-01, SECY-97-218-1, SECY-97-218-R, NUDOCS 9710100097
Download: ML20211L072 (3)


Text

-

................e.......

t o RELEASED TO THE PDR i(~

i - hN)G S

l s

1 dcto

.... s e. e e.... s.init;ats

.e...ee

,o POLICY ISSUE Sectember 29.1997 SECY-97-218 EQB:

The Commissioners FROM:

L. Joseph Callan Executive Director for Operations l

EUBJECT:

SPECIAL PROVISIONS FOR TRANSPORT OF LARGE QUANTITIES l

OF PLUTONIUM (RESPONSE TO STAFF REQUIREMENTS MEMORANDUM -

l SECY 96 215)

PURPOSE:

l l

In an October 31,1996, Staff Requirements Memorandum for SECY 96-215, Requirements for j

Shipping Packages Used to Transport Vitrified Wastes Containing Plutonium, the Commiscion directed the staff to " address whether the technical basis for 10 CFR 71.63 remains valid, or whether a revision or elimination of portions of 10 CFR 71.63 is needed to provide flexibility for current and future technologies." The purpose of this paper is to inform the Commission that the staff believes the technical bases for 10 CFR 71.63 remain valid and that the previsions provide adequate flexibility for current and future technologies. The staff believes it is desirable to retain those provisions of 10 CFR 71.63 that are not being covered by a separate rulemaking currently undelway.

BACKGROUND:

The provisions of 10 CFR 71.63 place certain requirements on the transport of large quantities of plutonium. For quantities greater than 0.74 terabecquerels (20 curies), the plutonium must

/

be in solid form, and must be shipped in a package that provides double containment.

Plutonium in the form of metal, or metal alloy, or reactor fuel elements is exempted from the ()g/

double containment provision, as are other plutonium-bearing solids as determined by the Commission.

g - /3 g/a /n ;; u,3 7e3 M&yGMT y

o p -6 cow 1 x

CONTACT: R. Chappell, SFPO!NMSS NOTE: TO BE MADE PUBLICLY AVAILABLE (301)415-8510 IN 5 WORKING DAYS FROM THE DATE OF THIS PAPER l$ !!,l l

llf1)ll 9710100097 970929 PDR SECY 97-218 R PDR

-e o

The Commissioners 2-The Commission adopted these requirements in 1974, in anticipation of a large increase in the number of plutonium shipments associated with commercial fuel reprocessing. In adopting these requirements, the Commission recognized that the release and dispersion of materialin transport, as a result of human error in packaging, were less likely for materialin solid form.

The requirement for packages with large quantities of plutonium to have secondary containment systems was intended to taka into account the fact that the solid plutonium may be in a respirable form, and to provide added assurance against leakage in the event of packaging errors, and the possible significant consequences of such an error.

The rule exempts nlutonium in the form of metal, or metal alloy, or reactor fuel elements, from the double containment requirement, since these materials are in essentially non respirable form.

A separate rulemaking (62 FR 25146) is currently underway to extend the exemption from double-containment provisions to include vitrified high level waste in canisters. The basis for the proposed rule is that this materialis also essentially non-respirable. The public comment period has ended, and comments have been received.

DISCUSSION:

The technical bases for the special provisions for transporting large quantities of plutonium remain valid. Although the special provisions were not based on quantitative evidence or statistical analysis, experience had shown that radbactive materials in liquid form and human error had contributed to previous package leakage events. Liquids are more susceptible to leakage than material in solid form, and shipment of plutonium in liquid form introduces other technical problems, including hydrogen generation and pressure build-up. For materialin dispersible form, a secondary containment vessel provides additional assurance against package failure because of human error in preparing the package for shipment, and provides an additional barrier against the potential release of plutonium in a transportation accident.

Experience indicates that it is practical to design, fabricate, and operate packages that provide double containment for shipment of large quantities of plutonium. Packages that have been designed for this purpose include:

The 125 8 package, a 100-ton lead shielded rail cask that was used to transport the fuel debris, partial fuel rods, and partial fuel assemblies from the Three Mile Island Unit 2 reactor. The damaged irradiated reactor fuel elements were not exempted from the double containment requirement becauso the form of the fuel and the cladding could no longer be relied upon to maintain the plutonium in a non-respirable form.

The TRUPACT-il package, which will be used to transport contact-handled transuranic waste by truck from Department of Energy (DOE) facilities to the Waste Isolation Pilot Plant (WIPP). Beginning in 1998, it is estimated that 20,000 I

shipments will be made to WIPP over a period of 30 years, using the TRUPACT-Il package. All DOE shipments to WIPP are required, by law, to be in packages certified by NRC. More than one hundred shipments have already been made

i 8

The Commissioners 3

between DOE facilities using the TRUPACT il package.

The Model 72 B package, currently being reviewed by staff, designed to transport high radiation (remote handled) transuranic wastew to WIPP.

The PAT 1 and PAT 2 packages, which are used for the transport of plutonium oxide powder by air. The PAT packages were designed to withstand severe aircraft crashes, and were certified for that purpose by the Nuclear Regulatory Commission to Congress.

]

The successful development and use of these packages, over many years, have shown that compliance with the double-containment provisions is practical, and can be implemented for a wide range of plutonium forms for all transport modes.

The staff has considered whether a revision or elimination of portions of 10 CFR 71.63 is needed to provide flexibility for current and future technologies. Except in connection with a 4

1979 amendment to a previous package approval, the staff is not aware of any exemptions that have been granted with respect to the double containment provisions of 10 CFR 71.63. The y

exemption was to allow shipment in the Model 6400 package of objects and equipment having L

plutonium contamination which had been fixed in place by painting or coating. This was later extended to allow fixation by polyurethane foam. Further consideration of the provisions in 10 CFR 71.63 would require a research effort, to study the number and type of future plutonium shipments that would be anticipated b)cause of changes to the commercial fuel cycle or to DOE's program to dispose of transuranic westes at WIPP.

COORDINATION:

l This paper has been coordinated with the Office of the General Counsel, which has no legal objection.

1 CONCLUSION:

The technical bases for 10 CFR 71.63 remain valid and the provisions provide adequate e

flexibility for current and future technologies. Except for the changes being considered in a separate rulemaking, the staff recommends that the provisions of 10 CFR 71.63 remain unchanged.

DISTRIBUTION:

Coimnissioners g

000 OCAA

. Joseph Calla OIG Ex cutive Direc or OPA or Operations OCA CIO CFO EDO SECY