JUN 251986 cms MEMORANDUM FOR:
J. J. Harrison, Chief, Engineering Branch FROM:
R. F. Warnick, Chief, Reactor Projects Branch 1
SUBJECT:
CALLAWAY AND PERRY DIESEL GENERATOR EXPERIENCE Recently Carl Paperiello asked that DRP notify DRS of diesel generator failures. While reviewing a Callaway special report submitted by Union Electric by letter dated April 15, 1986, (see attached) I noted that the A diesel generator has experienced one failure during valid testing and five failures during invalid testing out of 31 valid tests. You may want to followup on this at some future time.
I have also enclosed a copy of a Perry special report of a valid test failure of their Divieion 2 diesel generator.
/
fC%~
R. F. Warnick, hief Reactor Projects Branch 1
Enclosures:
1.
Ltr from Randolph to Keppler dtd 04/15/86, Special Rpt. 86-01, ULNRC 1294 2.
Ltr from Edelman to Keppler dtd 06/18/86, Special Rpt, PY-CEI/0lE-0213L cc w/o enclosures:
R. C. Knop W. L. Forney Bruce Little Jack Grobe hhh Obh 0h00 40 PDR S
[
C
[
Forney/J[p Knop Warnick
-gdo\\
NI
.