ML20211K778
| ML20211K778 | |
| Person / Time | |
|---|---|
| Issue date: | 12/10/1986 |
| From: | Stello V NRC OFFICE OF THE EXECUTIVE DIRECTOR FOR OPERATIONS (EDO) |
| To: | Asselstine, Roberts, Zech NRC COMMISSION (OCM) |
| Shared Package | |
| ML20211K781 | List: |
| References | |
| NUDOCS 8612150151 | |
| Download: ML20211K778 (2) | |
Text
,
1
()cg a..,...
- ggc 10 W AE0D/C603 MEMORANDUM FOR:
Chairman Zech Comissioner Roberts Comissioner Asselstine Comissioner Bernthal Comissioner Carr
'S FROM:
Victor Stello, Jr.
Executive Director for Operations
SUBJECT:
CASE STUDY REPORT - A REVIEW 0F MOTOR-0PERATED VALVE PERFORMANCE (AE0D/C603)
Enclosed for your information is a copy of the final AE0D case study report on operational experience involving motor-operated valve assemblies. This study was initiated by AE0D in response to action item 6(i) of the staff actions resulting from the investigation of the June 9,1985 event at Davis-Besse.
This action item requested that AE0D conduct a review of failures of l
safety-related motor-operated valves and provide an assessment of pertinent failure modes affecting valve assembly performance under design basis conditions.
The enclosed report documents AE0D's findings, conclusions, and recommendations resulting from the study and reflects the results of the peer review process.
In view of the comon NRC and industry objective of resolving identified safety issues relating to the operation of nuclear power plants in the most effective manner, we have forwarded a request to NUMARC to undertake appropriate industry initiatives to address the motor-operated valve assembly performance related problems and recomendations identified in the AE00 report.
The AE0D report has been forwarded to NRR, IE, RES, and the Regions for information.
7 g/
ff d' 8612150151 861210 PDR ORQ Nggg
(
$ ', U PDR
/
to hh
$%y
The Commissioners I would be pleased to provide any clarification or further information that you may desire.
Origirm1 Signed by Yictor Stengp Victor Stello, Jr.,
Executive Director for Operations
Enclosure:
(JISTRIBUTION:
As stated WDR AEOD C/F (w/o) cc w/ enclosure:
AE00S/F(w/o)
SECY R0AB C/F (w/ encl)
OGC EBrown, R0AB ACRS MChiramal SRubin WLanning KBlack MWilliams FHebdon CHeltemes, Jr., AE0D HDenton, NRR TRehm, ED0 VStello, E00 ED0 R/F JTaylor, IE DHumenansky, OCM (wlenckswe)
JRoe, D/EDO b1 A qauu(,
l
,n 0FC
- ROAB ROAB:SC t
- ROAB:BC
.....:_.Kjd......::....... Mc. :
. :... f.D....__:.. q M.....::....E,D,,j
- AEOD*D
- AEOD:0 NAME :EBrown:nc
- MChirarral
- SRubin N
- FHe) don
- CJHe ltemes
- VSt lo
- ...__....__.:...w........:.....
DATE:12/8//86
- 12M /86
- 12/ 4 /86
- 12/f/86
- 12/b/86
- 12/u /86 OFFICIAL RECORD COPY
/