ML20211H782

From kanterella
Jump to navigation Jump to search
Forwards Corrected Copies of Page 3,Table 1 from Annual Repts 31 & 32 for Vallecitos BWR
ML20211H782
Person / Time
Site: Vallecitos Nuclear Center
Issue date: 09/30/1997
From: Murray B
GENERAL ELECTRIC CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9710070128
Download: ML20211H782 (3)


Text

_ -

GE Nuclest Energy f

sewiwir< a,wy s m aa s o ce:ae I e khta400 Y,1%Colid sVnd heewan l A 94%6 Septeinber 30,1007 U.S. Nuclear Regulatory C<nninission Washington, D.C. 20555 Attentiont Docuinent Control Desk

Reference:

1.icense DPR 1, Docket fol8 Gentlemen:

Enclosett are three con'ecteil copies of page 3, Table i froin Annual Reports No. 31 anci No. 32 (six sheets total) for the Vallecitos lloiling Water Reactor (<leactivatetl).

The coirectect values in the reports are to two of the surface smears, beta-ganuna contamination levels for 12/05. The changes are:

1. Reactor Enclosure, hiain 11oor, General:

1.000 cpm /ft' x 10' (the incorrect value was 0.100).

2. Reactor liasement, East 1.athier, llottom: ~ 8.000 c[nn/ft'x 10' (the incoirect value was 0.800),

Sincerely, bi

11. hl. hluiray Senior 1.icensing Engineer (510) 862-1455

/ca Enclosures 9710070128 970930 l

(

PDR ADOCK 05000019 g

h, l

a

\\CWR Annual Report No. 31

{

I TABLE 1. RADIATION AND CONTAMINATION REPORT t

Contarnination Levels Radiation Surface Smears Airborne Levels Beta-Gamma *

  • Beta Gamma *

(mR/h Gamma)

(cpm /ft8 x 108)

(pCi/cc x 1010;

.10/94

.12/95 10/94 12/95

.10/14 12/95 Reactor Enclosure. Main Floor 1.-

General

<1

<.5 0.600 1.000 0.007 0.022 2.

Top of Spent Fuel Pit Cover

<1

<.5 2.0 0.400 0.006 0.017 Reactor Basement 1.

Upper Level, Field 3

3 2.

West Ladder, Bottom 4

8 1.0 3.000 3.

East Ladder, Bottom 6

5 0.500 8.000 0.004 0.440 4.

Between Recirculation Pumps 10 15 (2 ft. off deck)

Enclosure Stack, Outside Surface

<1 Main Valve Pit Lines and Valves

<1 N/A indicates readings not taken or not analyzed.

  • 24 hour decay.

For conversion to dpm, assume an instrument efficiency of 20%

NQII: Radiation levels, surface smears, and air samples may vary from survey to survey as they are taken in general areas rather than at specific locations.

3

'VBWR knnul Report N3. 32 TABLE 1. RADIATION AND CONTAMINATION REPORT Contamination Levels l

Radiation Surface Smears Airbome Levels

' Beta Gamma **

Beta Gamma *

(mR/h Gamma)

(cpm /n2 x 10')

(pCi/cc x 10'30)

M M

M M

12/95 M

Remetor Fnclosure. Main Floor 1.

General

<0.5

< l.0 1.000 0.500 0.022 0.016 2.

Top of Spent Fuel Pit Cover

<0.5

< l.0 0.400 0.800 0.017 0.008 ReactotBau ment 1.

Upper Level, Field 3-3 2.

West Ladder, Bottom 8

5 3.000 7.5 3.

East Ladder, Bottom 5

7 8.000 3.0 0.440 0.99 4.

Between Recirculation Pumps 15 12 (2 ft offdeck)

N/A indicates readings not taken or not analyzed.

  • 24 hour decay.-

"**For conversion to dpm, assume an instrument efficiency of 20%.

NOTE: Radiation levels, surface smears, and air samples may vary from survey to survey as they are taken in general areas rather than at specific locations.

3