Geugia Fow;r Company 333 Piedmont Avenue Atlanta, Georgia 30308 Telephone 404 526-6526 Mailing Address:
Post Office Box 4545 Atlanta, Georgia 30302 GeorgiaPower L. T. Gucwe
!!e sou!!nm eI<xtnc system Manager Nuclear Safety and Licensing SL-2005 0100m February 16, 1987 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C.
20555 NRC DOCKETS 50-424, 50-425 OPERATING LICENSE NPF-61, CONSTRUCTION PERMIT CPPR-109 V0GTLE ELECTRIC GENERATING PLANT UNITS 1, 2 OUTSTANDING SUBMITTALS LIST Gentlemen:
Enclosed for your information and use are listings of correspondence between Georgia Power Company and NRC-NRR for which written responses are required. lists those items awaiting GPC response while lists items awaiting NRC response.
Please contact this office if you have any questions.
Sincerely, dP@~'4 <-
L. T. Gucwa JH/1m Enclosures 8702250574 870216 4
PDR ADOCK 0500 P
/g' 0
\\
\\Y
j I
U. S. Nuclear Regulatory Commission February 16, 1987 Page Two c(w): Georgia Power Company Mr. R. E. Conway Mr. J. P. O'Reilly Mr. G. Bockhold, Jr.
GO-NORMS Southern Company Services, Inc.
Mr. d. A. Bailey Shaw, Pittman, Potts & Trowbridge Mr. B. W. Churchill, Attorney-at-Law Troutman, Sanders, Lockerman & Ashmore Mr. d. E. Joiner, Attorney-at-Law U. S. Nuclear Regulatory Coramission Dr. J. N. Grace, Regional Administrator Mr. H. H. Livermore, Senior Resident Inspector-Construction, Vogtle Ms. M. Miller, Licensing Project Manager, NRR Mr. J. F. Rogge, Senior Resident Inspector-0perations, Vogtle Georgians Against Nuclear Energy Mr. D. Feig Ms. C. Stangler 0100m
ENCLOSURE 1 TO SL-2005 NRC DOCKETS 50-424, 50-425 OPERATING LICENSE NPF-61, CONSTRUCTION PERMIT CPPR-109 V0GTLE ELECTRIC GENERATING PLANT UNITS 1, 2 CORRESPONDENCE AWAITING GPC RESPONSE ITEM SUBJECT UNIT (S)
REFERENCE
'l Verification of installation 1
SSER 4, Confirmatory of auxiliary boiler high flow Item 55, Page 7-2 annunciator 2
NUREG-0737 Item III.D.l.1, 1,2 License Condition (8)a Report of leakage outside containment 3
Loose Parts Monitoring 1,2 SSER 5, Page 4-1; SER, System baseline report Page 4-32 4
Verification of test 1,2 SSER 5, Confirmatory Item 30, results of electrical Page 8-3 distribution system 5
Main control board 2
SSER-4, Page 9-12 l
separation 6
Implementation of Unit 2 2
SSER 4, Confirmatory Item seismic separation program 54, Page 3-6 7
Incorporation of generic and 2
SSER 5, Confirmatory Item plant-specific recommendations 36, Page 9-3 for TDI diesel generators 8
Inorganic zinc coating of 1,2 License Condition (9);
diesel fuel oil tanks SSER 4, Page 9-22 9
Alternate Radwaste Facility 1
License Condition (10);
SSER 3, Open Item 20, Page 11-1; SSER 4, Page 11-1 10 Generic Letter 83-28:
Salem 1,2 SSER 4, Open Item 5, Page ATWS Items 2.2.1, 2.2.2, 4.2.3, 15-3; SSER 5, Page 15-1 4.2.4, 4.5.3 11 Plastic cable ties-long term 1,2 SSER 5, Open Item 22, Page report 3-5 12 IE Bulletin 80-06 2
SSER 5, Confirmatory Item 25, Page 7-1 El-1
a ENCLOSURE 1 TO SL-2005 NRC DOCKETS 50-424, 50-425 OPERATING LICENSE NPF-61, CONSTRUCTION PERMIT CPPR-109 V0GTLE ELECTRIC GENERATING PLANT UNITS 1,2 CORRESPONDENCE AWAITING GPC RESPONSE ITEM SUBJECT UNIT (S)
REFERENCE 13 Plant Safety Monitoring 1,2 SSER 5, Open Item 14(b) Pages System (PSMS) verification 7-1, 18-5 and validation report 14 Battery room spray protection 2
SSER 5, Page 8-2 15 Spent fuel racks 2-SSER 4, Page 9-1 16 Control Room Design Review
- 1,2 License Condition (8)c; SSER (CRDR) additional surveys and 5, Page 18-4 and Appendix T evaluations 17 Steam Generator Tube Rupture 1,2 License Condition (6); SSER 3, Confirmatory Items 48 and 49, Page 15-11 18 NUREG-0737 Item II.F.2, 1,2 License Condition (8)b; SSER Reactor Vessel Level Indication 4, Page 4-2 System (RVLIS) report 19 Groundwater reports-per 1,2.
SSER 2, Confirmatory Item 5, progr6m Page 2-3 20 Settlement reports-per 1,2 55ER 4, Confirmatory Item 7, program Page 2-3 21 FSAR revisions 1,2 GN '1228 (12/10/86);
GN-1257 (12/22/86);
GN-1254 (12/22/86);
GN-1277 (12/31/86);
GN-1279 (1/8/87);
GN-1308 (1/9/87);
GN-1312 (1/9/87);
22 Offsite Dose Calculation 1,2 NRC letter to GPC Manual (0DCM) revisions dated 1/13/87 23 ATWS Mitigating Systems 1,2 10 CFR 50.62(c)(6)
Actuation Circuitry (AMSAC)
Plant-Specific Report 24 Bypass and Inoperable 2
SSER 5, Confirmatory Item Status Panel 27, Page 7-3; SSER 4, Page 7-2; SER, Page 7-33 El-2 a
o ENCLOSURE 2 TO SL-2005 tJRC DOCKETS 50-424, 50-425 OPERATING LICENSE NPF-61, CONSTRUCTION PERMIT CPPR-109 V0GTLE ELECTRIC GENERATING PLANT UNITS 1,2 CORRESF0NDENCE AWAITING NRC RESPONSE ITEM SUBJECT UNIT (S)
REFERENCE 1
Volume reduction syr; tem 1,2 SER, Confirmatory Item 40, Page 11-12 2
SL-1883 (1/21/87) 3 Generic Letter 83-28: Salem 1,2 GN-l?29 (1/15/87)
ATWS Items 3.1.1, 3.'i.2, 3.2.1, 3.2.2, 4.5.1 E2-1