ML20211F905
| ML20211F905 | |
| Person / Time | |
|---|---|
| Site: | Summer |
| Issue date: | 06/05/1986 |
| From: | Decker T, Kreh J, Marston R NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| To: | |
| Shared Package | |
| ML20211F883 | List: |
| References | |
| 50-395-86-08, 50-395-86-8, NUDOCS 8606190155 | |
| Download: ML20211F905 (11) | |
See also: IR 05000395/1986008
Text
- ..
-_ _
'
.
.
'
UNITED STATES
. [q'[pn atro,}'o
.
NUCLEAR REGULATORY COMMISSION
REGION ll
,
g
j
,
101 MARIETTA STREET.N.W.
ATLANTA, GEORGI A 30323
I'
% m.* #
JUN 11 1936
' Report No.:
50-395/86-08
~ Licensee:
South Carolina Electric and Gas Company
Columbia, SC 29218
Docket No.:
50-395
License No.:
Facility Name: Virgil'C. Summer Nuclear Station
Inspection Condiicted: April 8-10, 1986
Inspector:
Mil [A
WL
d- 6-$b
/
J. L Kreh
Date Signed
Yf
b ~'.5 ~ S b
s -r , ,
R. R. Marston
-
Date Signed
Accompanying Personnel:
G. W. Bethke, R. T. Hadley, A. K. Loposer,
J. A. MacLellan (Battelle Pacific Northwest
la rat ries)
Approved by:
6/S' 86
T. R. Decker, Chief
Dhte' Signed
Emergency Preparedness Section
Division of Radiation Safety and Safeguards
SUMMARY
Scope: This routine, announced' inspection involved observation and evaluation of
a small-scale emergency preparedness exercise.
Results:
One violation was identified concerning an inadequate procedure for
notifying offsite authorities of an emergency. No deviations were identified.
8606190155 860605
PDH
ADOCK 0D000395
O
.
REPORT DETAILS
1.
Persons Contacted
.
Licensee Employees
- D. A. Nauman, Vice President, Nuclear Operations
- 0. S. Bradham, Director, Nuclear Operations
- L. A. Blue, Manager, Support Services
- K. E. Beale, Corporate Coordinator, Emergency Planning
- C. M. Counts, Station Coordinator, Emergency Planning
- D. R. Moore, Director, Quality & Procurement Services
- K. W. Woodward, Manager, Operations
- W. R. Baehr, Manager, Corporate Health Physics & Environmental Programs
- H. J. Sefick, Manager, Nuclear Security
- A. R. Koon, Jr. , Manager, Technical Support
- W. F. Bacon, Associate Manager, Chemistry
- M. N. Browne, Group Manager, Technical and Support Services
- R. M. McSwain, Coordinator, Corporate Communications
- B. C. Williams, Supervisor, Operations
- H. I. Donnelly, Senior Licensing Engineer
Other licensee employees contacted included technicians, operators, security
force members, and office personnel.
NRC Resident Inspector
R. L. Prevatte
- Attended exit interview
2.
Exit Interview (30703)
The inspection scope and findings were summarized on April 10, 1986, with
l
those persons indicated in Paragraph 1 above. The inspector discussed in
detail the violation described below in Paragraph 10 (failure to establish
,
!
and implement an adequate procedure for notifying offsite authorities of an
emergency).
Some explanatory remarks, but no dissenting comments, were
provided by the licensee.
A secord potential violation (concerning
protective action
recommendations) was also described but was later
determined to have been previously identified as a deficiency during a
Regional Office review of the licensee's Revision 15 to the Radiation
Emergency Plan (REP). During a telephone conversation on April 16, 1986,
the inspector informed C. M. Counts that no Notice of Violation would be
issued in connection with the latter finding. The licensee did not identify
1
as proprietary any of the materials provided to or reviewed by the
inspectors during this inspection.
3.
Licensee Action on Previous Enforcement Matters (92702)
1
This subject was not addressed in the inspection.
f
..
-
e
,
-
i'
,(.
-
,
,
i
?'
j
1
2
e
.
~
4.
Exercise Scenario (82301)
'
The scenario for the emergency exercise was reviewed to assure that
provisions were made to test the integrated capability and a major portion
of the basic elements ' defined in the licensee's emergency plan and
organization pursuant to~10 CFR 50.47(b)(14), Paragraph IV.F of Appendix E
to 10 CFR Part 50, and specific criteria defined in Section II.N of
.-
NUREG-0654, Revisio_n 1.
,.
The scenario was reviewed:in advance of the exercise and was discussed with
licensee represe'ntatiies during a controller / evaluator meeting on April 4,
1986.
While no maj6r problems with the scenario were identified, some
inconsistencies became apparent during the exercise.
The inconsistencies,
however, failed to detract from the overall performance of the licensee's
emergency 6tgan12ation.
No violations or deviations were identified.
,
"
5.
Fire Drill (82301)
The scenario for the fire drill was reviewed to assure that provisions were
<
made to test specific functions in the licensee's emergency plan pursuant to
.
10 CFR 50.47(b)(14), Paragraph IV.F of Appendix E ' to 10 CFR Part 50, and
specific criteria ' defined in Section II.N of NUREG-0654, Revision 1.
The scenario developed for the fire drill adequately exercised the
participating licensee organization and offsite local emergency agencies.
The scenario provided sufficient informntion to local support agencies
_
consistent with 'the scope of their participation in the drill.
The
[
performance of the Fire Brigade was adequate; however, an inspector observed
!
that additional controllers were needed to provide information to the Fire
Brigade regarding extent of the (simulated) fire, direction of the wind, and
'
other appropriate sensory simulations. Such information should preclude the
type of observed artificiality wherein the Fire Brigade rushed into an area
engulfed in.(simulated) smoke and fire.
Inspector
Follow-up
Item (50-395/86-08-01):
Considering
additional
controllers for fire drill to improve simulation of the fire emergency.
No violations or deviations were identified.
6.
Assignment of Responsibility (82301)
This area was observed to assure that primary responsibilities for emergency
response by- the licensee were specifically established, and that adequate
t
staff
was
available
to
respond
to
an
emergency
pursuant to
10 CFR 50.47(b)(1), Paragraph IV.A of Appendix E to 10 CFR Part 50, and
specific criteria defined in Section II.A of NUREG-0654, Revision 1.
l
h
The inspectors observed that specific assignments were made for the
e
licensee's emergency response organization, and that adequate staff was
'
>
available to respond to the simulated emergency. Review of the licensee's
'
activation procedure and call list indicated that sufficient technical staff
'
-
I
4
-
-
- - -
. -
- - -
-
. . .
-
.
.
3
was available to provide for continuous staffing of the augmented emergency
organization (although such staffing was not required by the scenario scope
and conditions).
The inspectors also observed the activation, staffing, and operation of the
emergency organization in the Technical Support Center (TSC), Emergency
Operations Facility (EOF), and Operations Support Center (OSC). At each
response center, the required staffing and assignment of responsibility
appeared to be consistent with the licensee's approved procedures, although
irregularities in TSC activation were identified (see Paragraph 13.b).
No violations or deviations were identified.
7.
Onsite Emergency Organization (82301)
The licensee's onsite emergency organization was observed to assure that the
following requirements were implemented pursuant to 10 CFR 50.47(b)(2),
Paragraph IV.A of Appendix E to 10 CFR Part 50, and specific criteria
promulgated in Section II.B of NUREG-0654, Revision 1: (1) responsibilities
for emergency response were unambiguously defined; (2) adequate staffing was
provided to assure initial facility accident response in key functional
areas at all times; (3) onsite and offsite support organizational
interactions were specified.
The inspectors observed that the initial onsite emergency organization was
adequately defined and that staff was available to fill key functional
positions.
The on-duty Shif t Supervisor assumed the duties of Interim
Emergency Director promptly upon initiation of the simulated emergency and
managed the response until relieved by the Director, Nuclear Operations.
With the exception of the timeliness of notifications to offsite authorities
(see Paragraph 10), required interactions between the licensee's emergency
response organization and State and local support agencies were adequate and
consistent with the scope of the exercise.
No violations or deviations were identified.
8.
Emergency Response Support and Resources (82301)
This area was observed to assure that arrangements for requesting and
effectively using offsite assistance resources were made pursuant to
10 CFR 50.47(b)(3), Paragraph IV.A of Appendix E to 10 CFR Part 50, and
specific criteria promulgated in Section II.D of NUREG-0654, Revision 1.
Licensee contact with offsite organizations was conducted in accordance with
approved procedures and was consistent with the scope of the exercise.
Assistance resources from State and local agencies were available to the
licensee.
No violations or deviations were identified.
.
.
-
a
,
=
_
=
4
_-
9.
Emergency Classification System (82301)
{
This area was observed to assure that a standard emergency classification
j
-
and action level scheme was in use by the licensee pursuant to
10 CFR 50.47(b)(4), Paragraph IV.C of Appendix E to 10 CFR Part 50, and
.
specific criteria promulgated in Section II.D of NVREG-0654, Revision 1.
'
An emergency action level matrix was used to classify the emergency and
j
escalate to more severe emergency classifications as the simulated emergency
_1
progressed.
The licensee's current classification system, known as the
K
" Fission Product Barrier Approach to Emergency Event Classification," was
implemented via REP Revision 15 (dated September 1985) and was compre-
hensively reviewed during an inspection in February 1986 (see NRC Report
No. 50-395/86-05). As of the date of the exercise, a final determination
(by NRC Headquarters and the Regional Office) of the adequacy of the
licensee's classification system had not been made; such a determination was
_
considered to be outside the scope of the NRC's evaluation of this exercise.
Notwithstanding the above-stated limitation, certain incidental observations
were made during the exercise.
An inspector observed that the exercise
initiating event (an earthquake producins acceleration exceeding one-half of
that associated with the Safe Shutdown Earthquake [SSE], with no fission
-
product barriers breached) resulted in a Notification of Unusual Event
(NOVE) classification,
in accordance with EPP-001, " Activation and
Implementation of Emergency Plan."
However, this classification wa; not
i
consistent with the example initiating conditions (EICs) of Appendix 1 to
NUREG-0654. According to that guidance, the simulated earthquake would have
been straightforwardly classified as an Alert (EIC 17.a. " Earthquake greater
than OBE [ Operating Basis Earthquake] levels"), or, more conservatively, as
.
a Site Area Emergency (EIC 15.a, " Earthquake greater than SSE levels"). The
I
inspectors determined through review of the REP and implementing procedures
d
that the NOUE classification of the earthquake was indicative of the
A
tendency of the licensee's system to underclassify emergency conditions
d
relative to the EICs of NUREG-0654. As discussed earlier, the licensee's
1
classification scheme remains under review by NRC and is being tracked as an
i
unresolved item (50-395/86-05-01).
No violations or deviations were identified.
10. Notification Methods and Procedures (82301)
]
This area was observed to assure that procedures were established for
-
notification of State and local response organizations and emergency
'
personnel by the licensee, and that the content of initial and follow-up
messages to response organizations was established.
This area was further
observed to assure that means to provide early notification to the populace
within
the
plume
exposure pathway were
established pursuant to
-
10 CFR 50.47(b)(5), Paragraph IV.D of Appendix E to 10 CFR Part 50, and
specific criteria defined in Section II.E of NUREG-0654, Revision 1.
=
i
An inspector observed that notification methods and procedures were
,
available for use in providing information concerning the simulated
-
~
emergency conditions to Federal, State, and local response organizations,
-
-
-
...._
. ._ _ .. _ _ .
~
.
5
and to alert the licensee's augmented emergency response organizations.
However, notification of the State of South Carolina and local offsite
organizations was not completed in a timely manner following declaration of
each emergency classification (except General Emergency).
The inspectors observed the following time periods for the initial
notifications to State and country authorities of each emergency class
declaration (measured from declaration to the completion of the notification
process):
Emergency Classification
Notification Time
NOUE (fire drill)
28 minutes
NOUE (exercise)
25 minutes
Alert
33 minutes
Site Area Emergency
>15 minutes
General Emergency (required
15 minutes
notification of State only)
The licensee's demonstrated inability to provide timely notifications (i.e.,
"as soon as possible," according to Table 6.2 of the REP; within 15 minutes,
according to Appendix E of 10 CFR Part 50) was attributable to the fact that
five telephone calls were required (consecutive rather than concurrent, with
one to the State and one to each of the four counties in the 10-mile
emergency planning zone).
Until the TSC was activated, one individual
designated as Control Room communicator was responsible for all offsite
notifications.
During the exit interview, the Vice President for Nuclear
Operations acknowledged that the licensee had been aware of the notification
problem since October 1985, when a change in the State Warning Point
resulted in cessation of the previous arrangement whereby the licensee
notified only the State, which then relayed the notification to the four
counties. The licensee was considering the acquisition of a proprietary
radio system which would provide the capability of concurrent notifications
l
to the appropriate offsite authorities. The licensee's inability to make
timely notifications to offsite authorities during the exercise was
determined to be symptomatic of an inadequate notification procedure.
EPP-002,
" Communication
and Notifications,"
specified that offsite
notifications merely begin within 15 minutes after an emergency declaration,
and designated only one communicator to make the five required telephone
calls.
Failure to establish and implement an adequate procedure for
notifying offsite authorities of an emergency is a violation of Technical Specification 6.8.1.e.
Violation (50-395/86-08-02):
Inadequate procedure for implementing the REP
requirement for notification of offsite authorities.
l
l
An inspector observed that an Alert was declared while the Control Room
!
communicator was in the process of noti fying the NRC of the NOUE
,
classification.
However, the communicator did not terminate the ongoing
i
NOUE notification and immediately initiate the Alert notification as
i
explicitly required by Section 5.2 of EPP-002.
This was considered a
shortcoming correctable through appropriate training
emphasis;
the
.
.
6
\\
licensee's performance in this area will be examined during a future
exercise.
Inspector Follow-up Item (50-395/86-08-03):
Placing training emphasis on
transmission of current status information and termination of superseded
messages to NRC and offsite authorities.
The prompt notification system for alerting the public within the plume
exposure pathway was in place and was actuated following declaration of the
General Emergency.
In addition, the Emergency Broadcast System was
activated to provide citizens a demonstration of the means by which they
would be informed during an actual emergency.
One violation and no deviations were identified.
11.
Emergency Communications (82301)
This area was observed to assure that provisions existed for prompt
communications among principal
response organizations and emergency
personnel pursuant to 10 CFR 50.47(b)(6), Paragraph IV.E of Appendix E to
10 CFR Part 50, and specific criteria promulgated in Section II.F of
NUREG-0654, Revision 1.
The inspector observed communications within and between the licensee's
emergency response fa
tities, between the licensee and offsite agencies,
and between the offsite environmental monitoring teams and the EOF.
The
inspector also observed information flow among various groups within the
licensee's emergency organization. Emergency communications were generally
adequate and consistent with the scope of the exercise.
A breakdown in effective communications existed briefly between the TSC and
the Control Room when the Director of Nuclear Operations assumed the
position of Emergency Director, relieving the Shift Supervisor of his duties
as Interim Emergency Director but leaving the Control Room with the
responsibility for notifications (the TSC was not yet fully staffed). This
l
misunderstanding delayed transmission of the Alert notification to the State
and the counties.
'
l
No violations or deviations were identified.
l
'
l
12.
Public Education and Information (82301)
!
I
This area was observed to assure that information concerning the simulated
emergency was made available for dissemination to the public as required by
10 CFR 50.47(b)(7), Paragraph IV.D of Appendix E to 10 CFR Part 50, and
specific criteria defined in NUREG-0654,Section II.G.
Information was provided to the media and the public in advance of the
exercise.
The information included details on how the public would be
notified and what initial actions they should take in an emergency. A News
Media Area was established at the Nuclear Training Center and was well
equipped and coordinated. Two press conferences were observed and found to
be informative, accurate, and concise.
-
.
.
7
No violations or deviations were identified.
13. Emergency Facilities and Equipment (82301)
This area was observed to assure that adequate emergency facilities and
equipment to support an emergency response were provided and maintained
pursuant
to
10 CFR 50.47(b)(8),
Paragraph IV.E
of
Appendix E
to
10 CFR Part 50, and specific criteria defined in Section II.H of NUREG-0654,
Revision 1.
The inspectors observed the activation, staffing, and operation of the
emergency response facilities, and evaluated the equipment provided for
emergency use during the exercise. Emergency response facilities activated
during the exercise included the Control Room, TSC, OSC, and EOF.
a.
Control Room - (The Simulator functioned as the Control Room for the
exercise.)
The inspector observed that Control Room operations
personnel acted promptly to initiate appropriate responses to the
simulated emergency.
Emergency procedures were readily available,
routinely followed, and factored into accident assessment and
mitigation exercises.
Except in the case of the misunderstanding between the Control Room and
TSC as described above in paragraph 11, the Shift Supervisor and
Control Room staff were cognizant of their duties, responsibilities,
and
authorities.
These
personnel
demonstrated
an
adequate
understanding of the emergency classification system and the proper
use of procedures associated therewith.
The inspector polled the players at several points during the exercise
and determined that personnel were not consistently cognizant of the
emergency classification then in effect.
Examples: (1) At 9:55 a.m.
the Shift Technical Advisor thought the classification was Site Area
r
Emergency when in fact it was still Alert.
(2) At 12:02 p.m. several
!
persons, including the Assistant Shift Supervisor, believed the
,
classification was Site Area Emergency when in fact a General Emergency
l
was declared at 10:23 a.m.
Regular updates for the Control Room staff
would preclude such instances of misinformation. This matter will be
t
reviewed during a future exercise.
Inspector Follow-up Item (50-395/86-08-04): Keeping Control Room staff
l
informed of emergency status.
l
l
b.
Technical Support Center (TSC) - The TSC was activated and promptly
!
staffed following notifications of the simulated emergency conditions
leading to the Alert classification. The facility staff appeared to be
knowledgeable concerning their emergency duties, authorities, and
responsibilities, and the required operation appeared acceptable. The
!
inspector noted that updates by the Emergency Director were too
infrequent to keep all TSC personnel well informed regarding plant
status. This facility was provided with adequate equipment for support
of the assigned staff.
f
I
~
.
8
Status boards were strategically located to facilitate viewing by the
TSC staff. Status boards were updated as required to chronicle changes
in plant status, accident assessment, and mitigation throughout the
exercise.
Particularly noteworthy was the maintenance of the plant
parameter status board, which was updated at 15-minute intervals.
c.
Operations Support Center (OSC) - The OSC was promptly staffed
following activation of the REP. An inspector observed that teams were
assembled and deployed in a timely manner.
The OSC supervisor was
cognizant of his duties and responsibilities, and OSC operations were
well managed.
d.
Emergency Operations Facility (EOF) - The EOF was located in the lower
level of the Nuclear Training Center, approximately 2 miles from the
station. The facility appeared to be adequately designed, equipped,
and staffed to support the response to the simulated emergency.
E0F security / access control was observed to be appropriately
established and maintained.
Communications with other emergency
response facilities were reliable. Status boards and other graphics
were strategically located and well maintained.
No violations or deviations were identified.
14. Accident Assessment (82301)
This area was observed to assure that adequate methods, systems, and
equipment for assessing and monitoring actual or potential offsite
consequences of a radiological emergency condition were in use as required
by 10 CFR 50.47(b)(9), Paragraph IV.B of Appendix E to 10 CFR Part 50, and
specific criteria promulgated in Section II.I of NUREG-0654, Revision 1.
The accident assessment program included an engineering assessment of plant
status and an assessment of radiological hazards to onsite and offsite
personnel. During the exercise, the engineering accident assessment team
l
functioned adequately in analyzing the plant status to provide recommenda-
l
tions to the Emergency Director concerning mitigating actions required to
reduce damage to plant equipment, prevent releases of radioactive materials,
and terminate the emergency condition.
l
l
Radiological assessment activities involved several groups. A TSC group was
effective in estimating the radiological impact within the plant based on
f
in plant monitoring and onsite measurements.
Offsite radiological moni-
toring teams were dispatched to determine the level of radioactivity in
those areas within the path of the plume.
Radiological effluent data was
received in the EOF. The EOF calculations were compared on a timely basis
with those from TSC and with field data from offsite monitoring teams.
No
major discrepancies were observed.
No violations or deviations were identified.
.-
- . . .
. . .
_-
.-
--
--
-.
. -
"
.
4
!
9
t.
,15. -Protective Response (82301)
-
.
This area was. observed to assure that guidelines for protective actions,
consistent with federal guidance, were developed and in place, and protec-
tive actions for emergency workers, including evacuation of nonessential
l-
personnel, were implemented promptly as required by 10 CFR 50.47(b)(10) and
!
specific criteria promulgated in Section II.J of.NUREG-0654, Revision 1.
- .
The inspector observed.the licensee's program for personnel accountability.
The inspector noted that upon sounding of the . site evacuation - alarm,
personnel appeared to proceed promptly to designated assembly points. All
- personnel were accounted for within 30 minutes after the site evacuation
alarm was sounded.
4
l
The protective ' measures decision-making process was observed by the in-
spector. Recommendations issued by the TSC and EOF were timely, adequate,
and consistent with the criteria cited above.
Protective action recommen-
'
dations were provided by the licensee to the State of South Carolina and
local offsite organizations consistent with the scope of the exercise
+
scenario.
No violations or deviations were identified.
16. Radiological Exposure Control (82301)
4
This' area was observed to assure that methods for controlling radiological
l
exposures in an emergency were established and implemented for emergency
1
workers, and that such methods included exposure guidelines consistent with
EPA recommendations as required by 10 CFR 50.47(b)(11) and specific criteria
defined in Section II.K of NUREG-0654, Revision 1.
An inspector noted that radiological exposures were controlled throughout
,
the exercise by issuing supplemental dosimeters to emergency workers and by
conducting periodic radiological
surveys in the emergency response
facilities.
Exposure guidelines were in place for various categories of
!
emergency actions, and adequate protective clothing and respiratory
protection were available for use as required (although use of the latter
was simulated).
Health Physics control of radiation exposure, contamination, and radiation
area access appeared adequate.
Dosimetry was available and was used.
>
High-range dosimeters were available if needed.
No. violations or deviations were identified.
.17.
Exercise Critique (82301)
f
The licensee's critique of the emergency exercise was observed to assure
1-
that shortcomings identified as part of the exercise were brought to the
attention of management- for corrective action,
as
required by
10 CFR 50.47(b)(14), Paragraph IV.F of Appendix E to 10 CFR Part 50, and
,
specific criteria in Section II.N of NUREG-0654, Revision 1.
i
t
,
e
4
-n
, ,
-, ,,
.,
- . - . , - - -
- --
, . - , , . - - - + - - - - - , , , .
,,,.-,,,,-e
a
_,
,
r-
.
..
_
.
.
10
A formal critique was held on April 10, 1986, with exercise controllers and
evaluators, licensee management, and NRC representatives.
Weaknesses
identified during the exercise and plans for corrective actions were
discussed. Licensee action on identified weaknesses will be reviewed during
a subsequent inspection. (Observation of the licensee controller / evaluator
critique, held prior to the exit interview, was included as part of the
exercise evaluation. Those NRC findings not also identified by the licensee
were summarized during the exit interview).
No violations or deviations were identified.
18.
Inspector Follow-up (92701)
(Closed) Inspector Follow-up Item 50-395/85-18-02:
Disparity in dose
projections between TSC and EOF.
Dose assessment personnel in the EOF
communicated continuously with their counterparts in the TSC.
In each of
several observations by the inspector, dose projections at the E0F and TSC
were in agreement.
s
l
l