ML20211E683

From kanterella
Jump to navigation Jump to search
Amend 103 to License NPF-57,changes TS 3/4.8.4.2, MOV-TOP (Bypassed), to Relocate List of Applicable Valves (TS Table 3.8.4.2-1) to Plant UFSAR
ML20211E683
Person / Time
Site: Hope Creek 
Issue date: 09/16/1997
From: Stolz J
Office of Nuclear Reactor Regulation
To:
Public Service Electric & Gas Co, Atlantic City Electric Co
Shared Package
ML20211E686 List:
References
NPF-57-A-103 NUDOCS 9709300206
Download: ML20211E683 (7)


Text

.

90 ne:g At UNITED STATES g

g

}

NUCLEAR REGULATORY COMMISSICN WASHINGTON, D.C. maa "1 PUBLIC SERVICE ELECTRIC & GAS COMPANY ATLANTIC CITY ELECTRIC COMPANY DOCKET NO. 50-351 HOPE CREEK GENERATINC TTATION AMENDMENT T0 FACILITY OPERATING LICENSE Amendment No.103 License No. NPF-57 1.

The Nuclear Regulatory Commission (the Comicsion) has found that:

A.

The application for amendment filed by the Public Service Electric

& Gas-Company (PSE&G) dated July 7, 1997, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Comission's rules and regulations set forth in 10 CFh Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance:

(1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations set forth in 10 CFR Chapter I; D.

The issuance of this amendment will not be inimical to the common defense and seciarity or to the health ar.d safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR.Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-57 is hereby amended to read as follows:

9709300206 970916 PDR ADOCK 050003S4 P

PDR t

(2) Technical Soecifications and Environmental Protection Plan The Technical Specifications contained in Appendix A, as revised through Amendment No.103, and the Environmental Protection Plan contained in Appendix B, are hereby incorporated into the license.

PSE&G shell operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

In addition, paragraph 2.C.(14) to Facility Operating License No. NPF-57 is amended as follows:

(14) Additional Conditions The Additional Conditions contained in Appendix C, as revised through Amendment No.103, are hereby incorporated into this license.

Public Service Electric and Gas Company shall operate the facility in accordance with the Additional Conditions.

3.

This license amendment is effective as of its date of issuance and shall be implemented within 60 days.

FOR THE NUCLEAR REGULATORY COMMISSION Jh T Stolz, Direct o ect Directorate I-2 D ision of Reacter Proj3 cts - I/II Office of Nuclear Reactor Regulation Attachments:

1.

Page 1 to Appendix C of License

Changes to the Technical Specifications Date of Issuance: September 16, 1997

  • Page 1 of Appendix C is attached, for convenience, for the composite license

, to reflect this change.

ATTACHMENT TO LICENSE AMEND >iEHT NO.103 FACILITY OPERATING LICENSE NO. NPF-57 DOCKET NO. 50-354 1.

Insert Appenix C, Page 1 2.

Replace the -following pages of the Appendix "A" Technical Specifications with the attached pages. The revised pages are identified by Amendment number and contain vertical lines indicating the area of change.

Remove Insert 3/4 8-30 3/4 8-30 3/4 8-31 3/4 8-31 3/4 8-32 3/4 8-33 3/4 8-34 3/4 8-35 3/4 8-36 3/4 8-37 B 3/4 8-3 8 3/4 8-3 l

l

APPENDIX C ADDITIONAL CONDITIONS OPERATING LICENSE NO. OPR-57 Public Service Electric and Gas Company and Atlantic City Electric Company shall comply with the following conditions on the schedules noted below:

Amendment Additional Condition Implementation Number Date 97 The licensee is authorized to relocate certain The amendment Technical Specification requirements to shall be licensee-centrolled documents.

Implementation implemented of this amendment shall include the relocation within 60 days of these technical specification requirements from March 21, to the appropriate documents, as described in 1997.

the licensee's application dated January 11, 1996, as supplemented by letters dated February 26, May 22, June 27, July 12, December 23, 1996, and March 17, 1997, and evaluated in the staff's safety evaluation attached to this amendment.

103 The licensee shall relocate the list of "Hotor The amendment Operated Valves - Thermal Overload Protection shall be (BYPASSED)" from the Technical Specifications implemented (Table 3.8.4.2-1) to the Updated Final Safety within 60 days Analysis Report, as described in the licensee's from September 16, application dated July 7,1997, and evaluated 1997.

in the staff's safety evaluation attached to this amendment.

Amendment No. 97,103

ELECTRICAL POWER SYSTEMS MOTOR OPERATED VALVES - THERMAL OVERLOAD PROTECTION (BYPASSED)

LIMITING CONDITION FOR OPERATION 3.8.4.2 The thermal overload protection bypass circuit of eacl. motor operated valve (MOV) required to have thermal overload protection shall be OPERABLE.

APPLICABILITY: Whenever the MOV is required to be OPERABLE.

ACTION:

With the thermal overload protection bypass circuit for one or more of the above required MOVs inoperable, restore the inoperable thermal overload protection bypass circuit (s) to OPERABLE status within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> or declare the affected MOV(s) inoperable and apply the appropriate ACTION statement (s) for the affected system (s).

. SURVEILLANCE REQUIREMENTT, 4.8.4.2.1 The thermal everload protection bypass circuit for each of the above required MOVs shall be demonstrated OPERABLE:

a.

At least once per 18 months by the performance of a CHANNEL FUNCTIONAL TEST fort 1.

Those thermal overload protection devices which are normally in force during plant operation and bypassed only under accident conditions.

2.

A representative sample of at least 25% of those thermal overload prot 2 4 tion devices which are bypassed continuously and temporarily placed in force only when the MOVs are undergoing periodic or maintenance testing, such that the bypass circuitry for each thermal overload protection device of this type is tested at least once per 6 years.

3.

A representative sample of at least 25% of those thermal overload protection devices which are in force during normal manual (momentary push button contact) MOV operation and bypassed during remote manual (push button held depressed)

MOV operation, such that the bypass circuitry for each thermal overload protection device of this type is tested at least once per 6 years, b.

Following maintenance on the motor starter.

4.8.4.2.2 The thermal overload protection for the above required MOVs which are continuously bypassed and temporarily placed in force only when the MOV is underooing periodic or maintenance testing shall be verified to be contin'ously bypassed following such testing.

HOPd CREEK 3/4 8 30 Amendment No.103 i

PAGES 3/4 8-31 THROUGH 3/4 B-37 HAVE BEEN DELETED I

HOPE CREEK 3/4 8-31 Amendment No.103

ELECTRICAL POWEP SYSTEMS BASES A.C.

SOURCES, D.C.

SOURCES and ONSITE POWER DISTRIBUTION SYSTEMS (Continued)

Operation with a battery cell's parameter outside the normal limit but within the allowable value specified in Table 4.8.2.1-1 is permitted for up to 31 days. During this 31 day period (1) the allowable values for electrolyte level ensures no physical damage to the plates with an adequate electron transfer capability; (2) the allowable value for the average specific gravity of all the cells, not more than.020 below the manufacturer's recommended full charge specific gravity ensures that the decrease in rating will be less than the safety margin provided in sizing; (3) the allowable value for an individual cell's specific gravity, ensures that an individual cell's specific gravity will not be more than.040 below the manufacturer's full charge specific gravity and that the overall capability of the battery will be maintained within an acceptable limits (4) the allowable value for an individual cell's float voltage, greater than 2,07 volts, ensures the battery's capability to perform its design f unction; (5) the TABLE 4.8.2.1-1 NOT.P. TION 31 day ACTION time was derived taking into consideration that while battery capacity is degraded, sufficient capacity exists to perform the intended function while providing a time period adequate to permit full restoration of the battery cell parameters to nornal limits.

3 /4. 0. 4 ELECTRICAL EOUIPMENT PROTECTIVE DEVICES Primary containment electrical penetrations and penetration conductors are protected by demonstrating the OPERABILITY of primary and backup overcurrent protection circuit breakers by periodic surveillance.

The surveillance requirements applicable to lower voltage circuit breakers provides assurance of breaker reliability by teating one representative sample of each manufacturers brand of circuit breaker.

Each manufacturer's molded case and metal case circuit breakers are grouped into representative samples which are than tested on a rotating basis to ensure that all breakers are tested.

If a wide variety exists within any manufacturer's brand of circuit breakers, it is necessary to divide that manufacturer's breakers into groups and treat each group as a separate type of breaker for surveillance purposes.

The OPERABILITY or bypassing of the motor operated valves thermal overload protection continuously or during accident conditions by integral bypass devices ensures that the thermal overload protection during accident conditions will not prevent safety related valves from performing their function. The Surveillance Requirements for demonstrating the OPERABILITY or bypassing of the thermal overload protection continuously or during accident conditions are in accordance with Regulatory Guide 1.106 " Thermal overload Protection for Electric Motors on Motor Operated Valves," Revision 1, March 1977.

The list of MOVs required to have thermal overload bypass circuitry is contained in UFSAR Table 8.3-11.

HOPE CREEK B 3/4 8-3 Amendment No.103

-