Request for Permission to Enter Upon Util Land on 861119 to Inspect High Density Spent Fuel Racks Proposed for Use in Spent Fuel Pools of Units 1 & 2,interrogatories & Request for Documents.W/Certificate of Svc.Related Correspondence
ML20211D538
Person / Time
Site: Diablo Canyon  
Issue date: 10/17/1986
From: Ferguson R
Sierra Club
To:
Atomic Safety and Licensing Board Panel
References
CON-#486-1162 86-523-03-LA, 86-523-3-LA, OLA, NUDOCS 8610220216
Download: ML20211D538 (6)


Text

-

y f 2-00LKETED USNRC UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION

'86 m:T 20 P5 :22 BEFORE THE ATOMIC SAFETY AND LICENSING BOARD OFFICE cr.

ifo

)

00CKEI N A i m a In the Matter of

)

Docket NosER50-275-OLA

)

and 50-323-OLA PACIFIC GAS AND ELECTRIC COMPANY

)

)

ASLBP No. 86-523-03-LA (Diablo Canyon Nuclear Power Plant,

)

Units 1 and 2)

)

REQUEST' OF THE SIERRA CLUB FOR PERMISSION TO ENTER UPON LAND OWNED OR CONTROLLED BY PACIFIC GAS AND ELECTRIC COMPANY DATED OCTOBER 17, 1986 Pursuant to 10 CFR Section 2.741, the SIERRA

CLUB, as intervenor in the above referenced case, requests permission to enter the grounds and buildings of the Diablo Canyon Nuclear Power Station for the purpose of inspecting the high density spent fuel racks proposed for use in the spent fuel pools of Units 1 and 2.

The inspection shall take place on Wednesday, November 19, 1986, unless an earlier date is mutually agreed upon by the Sierra Club and PG&E.

The inspection team shall consist of no more than six (6) individuals to be chosen by the Sierra Club.

The inspectors will make photographs and measurements of the high density racks in such a way as to avoid all possibility of damage to the racks.

Ladders or other equipment shall be used as needed to measure and photograph the girdle bars and the upper parts of the racks.

PG6E is requested to provide, no later than Monday, November 17,

1986, the name and telephone number of a

responsible representative of the Company to serve as liason with the inspection team.

Detalls of the inspection involving arrival and departure times, transportation, etc., are expected to be amicably 8610220216 861017 PDR ADOCK 05000275 9

G PDR 1

OJ

e-resolved by the Company representative and Dr. Richard Ferguson of the Sierra Club.

SIERRA CLUB'S INTERROGATORIES AND REQUEST FOR PRODUCTION OF DOCUMENTS TO THE APPLICANT, DATED OCTOBER 17, 1986 The SIERRA CLUB. requests the Applicant, Pacific Gas and Electric Company, to answer the. interrogatories set forth below.

INSTRUCTIONS

1) Each interrogatory is to be answered separately and fully in writing under oath or affirmation by the officer of, employee of, or consultant to the Applicant who has personal knowledge thereof.

2)

In case of an objection, the reasons for the objection shall be stated in full.

3)

Requests involving

" records and documents" shall be understood to refer to any

books, papers,
articles, letters,
menos, meeting summaries or transcripts, computer
programs, technical studies, or other documentary materials relating to the subject (s) of the interrogatory which are known to any officer of, employee of, or consult' ant to the Applicant.

4)

Requests involving " reports of calculations" shall be understood to refer to any documents containing or referring to

)

assumptions, equations, formulas, data, descriptions of analytical techniques, computer programs, theoretical results or any other information used to assess qualitatively and/or quantitatively the subject (s) of the interrogatory which are known to any officer of, i

l employee of, or consultant to the Applicant.

l

5) All references to " spent fuel pools",

" pool floor", " pool i

i I

2 J

walls",

etc..

refer to the spent fuel pools at the.Diablo Canyon 1

Nuclear Power Plant. Units 1 and/or 2.

4

6) All references to " spent fuel racks",

etc., refer to high density spent fuel racks proposed for the reracking of the spent fuel pools at'Diablo Canyon by the license amendment currently under consideration.

7)

Requests involving references to the behavior of spent fuel racks refer to behavior induced by postulated seismic excitations such as the postulated Hosgri Event.

l

8) References to longer works such as the SER, the FSAR, the Reracking Report, etc.,

should refer to section numbers or other specific identification."

9)

Pursuant to the schedule set forth in the order of the Atomic Safety and Licensing Board of August 28,

1986, answers to these interrogatories are due November 6, 1986.

INTERROGATORIES 1)

This interrogatory refers to the document " Seismic Analysis of High Density Fuel Racks for Pacific Gas and Electric Company for

)

Diablo Canyon Nuclear Power Station".

Revision 3, by Alan Soler, TM Report #779. This document was supplied to the Club in response to the first round of requests for documents in the current proceeding and labeled Document 18.

a)

In reference to page II-14:

identify all of the generalized forces included in the term Oq, found in the equation of motion for the generalized coordinate q g All parameters and I

variables appearing in these force terms should be explicitly 1

identified.

i 3

b)

In 'particular, do the generalized forces used for the analysis of rack behavior include forces of the

" gap closure" type as discussed in the paper " Dynamic Coupling in a

Closely Spaced Two Body System Vibrating in a Liquid Medium:

the Case of Fuel Racks",

A.I.

Soler and K. P.

Singh, 3rd Keswick Int Conf.

Vibration in Nuclear Plants, May 1982, U.K.,

for example.

2)

What were the criteria used to determine the spacing of the high density racks in the spent fuel pools?

In particular, what role did potential rack-rack and rack-wall i nt e ra c t i on.s play in the positioning of the racks?

REQUEST FOR PRODUCTION OF DOCUMENTS The SIERRA CLUB requests that the Applicant provide' copies of the following:

1)

Regarding the document " Seismic Analysis of High Density Fuel Racks for Pacific Gas and Electric Company for Diablo Canyon Nuclear Power Station", TM Report #779 by Alan Solers a) all pages of the original version and revisions 1 and 2

which differ from those of revision 3.

2)

All docusents containing references to the criteria regarding rack spacing (see interrogatory #2).

Rea tfully submitted, p4 ~-l/

mW

[Dr.

Richard B.

Ferguson Vice-Chairman Sierra Club Santa Lucia Chapter October 17, 1986 4

1

1 i

C0(ncts, UNITED STATES OF AMERICA USNRC NUCLEAR REGULATORY COMMISSION 0l$[20PS:22 BEFORE THE ATOMIC SAFETY AND LICENSING

)

0FFIg ;;; -

In the Matter oft

)

DockIYEkhsA.50dp5-OLA

)

and"502323-OLA PACIFIC GAS AND ELECTRIC COMPANY

)

)

ASLBP No. 86-523-03-LA CDiablo Canyon Nuclear Power Plant,

)

Units 1 and 2)

)

CERTIFICATE OF SERVICE I hereby certify that copiesoof the REQUEST OF THE SIERRA CLUB FOR PERMISSION TO ENTER UPON LAND OWNED OR CONTROLLED BY PACIFIC GAS AND ELECTRIC

COMPANY, and INTERROGATORIES AND REQUEST FOR PRODUCTION OF DOCUMENTS FROM PG&E AND THE NRC in the above-captioned prodeeding have been served on the following by deposit in the United States mail, first class, this 17th day of October, 1986.

B. Paul Cotter, fr., Chairman Administrative Judge Atomic Safety and Licensing Board Panel U.S.

Nuclear Regulatory Commission Washington, DC 20555 Glenn O.

Bright Administrative Judge Atomic Safety and Licensing Board Panel U.S.

Nuclear Regulatory Commission Washington, DC 20555 Dr. Jerry Harbour Administrative Judge Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, DC 20555 Ms. Nancy Culver 192 Luneta Street San Luis Obispo, CA 93401 Bruce Norton, Esquire e/o P.h. Crane Pacific Gas and Electric Company 77 Beale Street, 31st Floor San Francisco, CA 94106 1

e.

.s Mrs. Jacquelyn Wheeler 2455 Leona Street San Luis Obispo, CA 93401 Philip A.

Crane, Jr..

Esquire P.O.

Box 7442 San Francisco.-CA 94120 Laurie McDermott, Co-ordinator CODES 731 Pacific Street Suite #42 San Luis Obispo, CA 93401 Mr. Lee M. Gustafson Pacific Gas and Electric Company Suite 1100 1726 M Street NW Washington, DC 20036-4502 Docketing and Service Branch Office of the Secretary U.S.

Nuclear Regulatory Commission,

Washington, DC 20555 Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, DC 20555 Atomic Safety and Licensing Appeal Board U.S. Nuclear Regulatory Commission Washington, DC 20555 Henry J.

McGurren, Esquire Lawrence J. Chandler, Esquire Office of the Executive Legal Director U.S.

Nuclear Regulatory Commission

/

Washington, DC 20555 i

,o e+, W (Irguson r.

Richard B.

Vice-Chairman Sierra Club Santa Lucia Chapter 2