Forwards Survey Findings & Results Re Background Levels for Direct Readings for Beta/Gamma Background for Interior
ML20211B069
Person / Time
Site: 07000133
Issue date: 09/16/1997
From: Grube R
SEVENSON ENVIRONMENTAL SERVICES, INC.
To: Buckley J
NRC
References
NUDOCS 9709250054
Download: ML20211B069 (4)


Text

~

19/8@i1%@? 8@:G@

41922922?2 SE\\EtGON EtW SER INC F Cf. 02 f

Inc. and will be hek! until such time as authorhed by the NRC for disposal.

I SURVEY FINDINGS AND RESULTS Subsequent volumes contains tables of data, affected during the survey Data is summarked in tables and the volumes aho contain resuhs ofdata interpretations and comparisons whh guidelines and xmditions established as surg objectiws.

4.1 BACKGROUND

LEVELS Direct readings for beta / gamma background for interior and exterior areas ury based on the material being surveyed. The beta gamma background levels in opta along with their associated codes are r

listed la Table E.1 'Ibese represent ten one minute readings for each material taken with a Ludlum uaxlet 2221 scaler /rasemeter with a 43-68,100 cut window, gas proportional detector. It should be noted that background fluctuated whhin a given Insterial and higher leveh can be obtained. Table E-1 does not reflect the maximum reading for each mate lal. Small rooms or areas where more than one wall was mode ofmatedal with elevated background readings in close proximity created many of the fahe readings in excess of the guideline value. Original survey resuhs in cpm were adjusted using the sww buckground rates to obtain the corrected dpm in the attached tables. Background levels for direct alpha readiD8s did not vary appreciably for the diffemt materials and chher a 0 4 or a 0.5 cpm background was used for obtaining corrected counts per minute, this information is also comaland in Table E 1. Background levels for alpha scans did not vary appreciably for the different materials and either a 0.4 or a 0.5 cpm background was used for obtaining corrected counts per minute, this ivforumtion is contained in Table E 1. Background levels fbr beta / gamma scans are listed in Table E-1; 44-47 cpm was used. Background levels for instrumentation used to count smears varied slightly each day and is recorded on the individual survey forms. Background levels for the smear counting irvenimmation as well as other background levels are contained in Table 2.

9709250054 970916 PDR ADOCK 0700 1 3 C

12 Q) f

}2 *n

...=.

1 Table E-1 3

Background Data Summary for Buiking Materials N

j l

Direct Survey Scan Sarvey a

t P obe 43-68 43-65 444 43-65 Code Area Material Beta B:ta Bcta Beta Beta Alpha Beta Alpha

/ Gamma

/ Gamma Gamma

/ Gamma

/Gamena Bkg

/ Gamma Bkg Bkg Min Max SD Uncert.

Bkg C-1 Ceiling Concrete 357 345 377 9.91 31.16 0.5 44-47 0.5 f"d g

C-2 Ceiling Steel 207 175 246 19.18 23.72 0.5 44-47 0.5 I

j F-1 Flox Concrete 357 345 377 9.91 31.16 0.5 44-47 0.5 F-2 Flox Hardwood 262 243 277 12.09 26.72 0.5 44-47 0.5 g

9 O-I Outside Roof 7 Dirt 863 824 899 20.37 48.46 0.5 44-47 0.5 O-2 Odside Roof 372 322 432 35.67 31.84 0.5 44-47 0.5 Tar / Cinder O-3 Outside A**

412

,395 437 13.44 33.49 0.5 44-47 0.5 W-1 Wall Bsick 509 427 572 46.23 37.23 0.5 44-47 0.5 W-2 Wall Cinder Block 444 406 489 26.07 34.77 0.5 44-47 0.5 h

W-3 Wall Coerpr=ition 219 195 242 1141 24.44 05 44-47 0.5 im j

W-4 Wall Gis2ed Blod 857 798 961 53.39 48.28 4 *i 44-47 0.5 W-5 Window Akamiana 250 250 286 13.27 27 11 0.5 44-47 0.5

.g W-6 Wa3 Concrete 357 345 377 9.91 3;.16 0.5 44-47 0.5 5

X-1 Brace Steel 207 175 246 19.18 23.27 0.5 44-47 0.5 g

e 13
  • s2 2

'o

Table E-1 C

Bt.ckgmund Data Surnmary for Building Matenals

]

X-10 Pilbur Concrete 357 345 l377 9.91 31.16 0.5 44-47 0.5 4

, X-11 Pipe Steel 207 875 246 19.18 23.72 0.5 44-47 0.5 X-12 Stairs StecI 207 175 246 19.18 23.72 0.5 44-47 0.5 X-13 EMric Box Metal 270 244 286 13.27 27.11 0.5 44-47 0.5 X-14 Vex Meta!

'270 244 286 13.27 27.11 0.5 44-47 0.5 X-15 Drain Ceramic 743

'693 774 26.87 44.97 0.5 44-47 0.5 X-2 Bracket Steel 207 175 246 19..8 23.72 0.5 44-4 7 0.5 7

.X-3 Cabinet Wood 265 245 286 12.90 2&S6 0.5 44-47 0.5 X4 Door Wood 265 245 286 12.90 2&86 0.5 44-47 0.5 X-5 Doct Metal l 270 244 286 13.27 27.11 0.5 44-47 0.5 W

X-6 Hoad Metal 278 244 286 13.27 27.1I 9.5 44-47 0.5 X-7 I-Bann Steel 207 I75 246 19.I8 23.72 0.5 44-47 0.5 X-8 Landing Steel 207 175 246 19.18 21.72 0.5 44-47 0.5 X-9 List Metr 270 244 286 13.27 27.11 0.5 44-47 0.5

~

5 St U

0 o

IP-l$

14 (C$

.h 9

}

y

wwrnwrmways eJararena srwrmlorrwenc mi FAX MESSAGE Sevenwn Environmental Services FAX NO: (419) 229-2272 2749 Lockport Rd Niagara Falls, NY 14305 T EL NO: (419) 229-2071 nate: 9-&-97 To:

3hn 3uckkv' Company:

UkC-Fax #:

301 Y!5'5397

$r iAh_

From:

n rev G

Total Number of Pages including Cover Sheet:

Y Message; ks55 O AA A S h o n r ex shcusc-,

u i

0 D'\\

QD\\

.:s e n lllll!I!!l[l]ljll!!:l}lUll!!Ill 1