Text
t,4, Dd UNITED STATES j Dx's., 3.. g NUCLEAR REGULATORY COMMISSION E
WASHINGTON. O. C. 20555
- g;Mf/
glG S d 94 MEMORANDUM FOR: Those on Attached List FROM:
LeMoine J. Cunningham, Chief Section 2, Operating Reactor Programs Branch Division of Quality Assurance, Safeguards, and Inspection Programs Office of Inspection.and Enforcement
SUBJECT:
UPDATED GUIDANCE ON FIT TESTING OF BIOPAK 60-P RESPIRATOR USERS This letter provides updated guidance on fit testing of BioPak 60-P respirator users in response to inquiries from licensees and inspectors regarding implemen-tation of previous guidance (memo to L.R. Greger, RIII, from L.J. Cunningham, IE August 8, 1983 - copy enclosed).
Licensee and inspectors have inquired as to what constitutes an acceptable method for performing quantitative fitting of the wearers of this apparatus as required in footnote 1, to Appendix A of Part 20; specifically, is it acceptable to check the fit of the device (the
' face to facepiece sealing capability) by testing the user while the user is
,> wearing just the facepiece equipped with a.high efficiency filter supplied by i
the manufacturer of the device.
Previous guidance stated that the wearer must don the entire unit for fit testing since it was felt that fitting the face-piece with a high efficiency filter that is capable of allowing no more than 0.03% leakage would preclude measurement of the required 0.02t leakage or less 1
through the face to facepiece sealing area.
However, the 0.03% leakage allowed for high efficiency filters is determined with a more penetrating. aerosol (monodispersed) than used in fit testing.
Therefore, it is possible to measure the 0.02% leakage accurately with the facepiece equipped with a high efficiency filter (0.02% leakage corresponds to a fit factor of 5000).
l Requiring a fit factor of 5000 in the negative pressure air-purifying mode is l
too restrictive.
This approach to fit testing allows no credit for protection
~
I provided by the positive pressure inside the facepiece generated by the devic'e in its normal mode of operation.
Positive pressure inside the facepiece can compensate for inward leakage of contaminants to some extent by ensuring air i
circulating through the device is leaked outward instead of leaking contami-l nants into the worker's breathing zone.
However, in this device that protec-tion is obtained at a large cost if the fit is poor and outward leakage is substantial because reduced service life results as outward leakage of air is made up from the small volume of oxygen carried by the user.
The volume carried is sufficient to exchange the volume of carbon dioxide released in respiration with compressed oxygen.
Carbon dioxide is removed from the circulating air by the sorbent scrubber'.
~m B610170009,840829-3 C.
v Multiple Addressees A hard and fast number that delineates good from poorly fitting respirators is not available.
In the opinions of many experts in the field of respiratory protection, 1000 seems to represent a. reasonable number for distinguishing between good and poorly fitting respirators.
It is recomended that licensees use this number as a guide for detennining if an acceptable fit ~has been achieved with this device.
For those persons that are unable to attain a fit factor of 1000 with.just the facepiece in negative pressure mode participation in emergency, potentially IDLH situations should be restricted.' This -person may experience drastically reduced service time which reduces emergency response capability as well as
' hindering escape from a potentially life threatening' situation.
The intent of the previous guidance was not to verify proper functioning of the entire unit.
The operability of the assembled unit is checked after mainte-nance and before each use.
In addition, fit testing of workers wearing the assembled unit in the case of this apparatus was presenting other problems due to the icw makeup volume and leakage detection interference from backgroun'd water vapor droplets and particulates from the carbor, dioxide scrubber system.
Based on the interference problem that has been reported and revaluation of the previous guidance it is now recomended that fit testing of wearers of the BioPak 60-P be performed with just the facepiece equipped with a high effi-ciency filter and that.a factor of 1000 be considered an acceptable fit.
A recomendation will be made to RES to update Appendix A to ir.clude the intent of this interpretation in'th9 next rule change.
If you have any questions regarding this guidance please contact Lynnette Hendricks of my staff (492-9728) or Jim Wigginton, IE (492-4967).
l LeMoine J. Cunningham, Chief Section 2, Operating Reactor Programs Branch Division of Quality Assurance, Safeguards i
l and Inspection Programs Office of Inspection and Enforcement
Enclosure:
Memorandum L.R. Greger fru L.J. Cunningham dtd. 8/8/84 l
l l
a
. Distribution:
DCS 016 ORPB reading DQASIP Reading J.N. Grace, IE J.G. Partlow, IE P.F. McKee, IE L.J. Cunningham, IE L. Hendricks, IE S.L. Ramos, IE J.E. Wigginton, IE D.P. Allison,'IE R.L. Baer, IE E.L. Jordan, IE F. Congel, NRR R. Serber, NRR
k f[g[ypt IE:
ORPB IP:
LHe
- ric LJC ingham n
mm<
Byu
y.
Attached List James H. Joyner, Chief Nuclear Materials and Safeguards Branch Region I Kenneth P. Barr, Chief Nuclear Materials and Safeguards Branch Region II William L. Axelson, Chief Nuclear Materials and Safeguards Branch Region III Ronald R. Bellamy, Chief Radiological Protection Branch Region I Douglas M. Collins, Chief Emergency Prepare.iness and Radiological. Protection Branch Region II Carl J. Paperiello, Chief Emergency Preparedness and Radiological Protection Branch
' Region III Ramon E. Hall, Chief Technical Program Branch Region IV Frank A. Wenslawski, Chief Radiological Safety Branch Region V l
l r
l
._.- __.