Person / Time
Issue date: 08/17/1999
From: Stephen Dembek
NRC (Affiliation Not Assigned)
To: Richards S
NRC (Affiliation Not Assigned)
References
NUDOCS 9908230199
Download: ML20211A133 (5)


Text

7 c

@ *Eco e

o e,

UNITED STATES

.O B

NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20066-0001

,g#

August 17, 1999 MEMORANDUM TO: Stuart A. Richards, Director Project Directorate IV & Decommissioning Division of Licensing Project Management Office of Nuclear Reactor Regulation FROM:

Stephen Dembek, Chief, Section 2

P Project Directorate IV & Decommit ioning Division of Licensing Project Management Office of Nuclear Reactor Regulation

SUBJECT:

NOTICE OF MEETING WITH ABB-COMBUSTION ENGINEERING, INC.

DATE & TIME:

Thursday, September 2,1999 8:30 a.m. - 4:30 p.m.

LOCATION:

ABB Combustion Engineering 12300 Twinbrook Parkway Suite 330 Rockville, MD 20852 PURPOSE:

Present common qualified platform equipment qualification results. Seo the attached agenda for specific discussion topics.

l PARTICIPANTS:

Participants of the meeting from the NRC include members of the Office of Nuclear Reactor Regulation.

l NBC ABA Eric Lee Marty Ryan Keith Mortensen Ray Senechal

/

Attachment:

Agenda cc: See next page

['.h Meetings between NRC technical staff and applicants or licensees are open for interested members of the public, petitioners, intervenors, or other parties to attend as observers pursuant to the " Commission Policy Statement on Staff Meetings Open to the Public," 59 Federal Reaister 48344,9/20/94. The session from 10:00 A.M. until 4:30 P.M. will be a closed meeting.

During this time, ABB will be presenting information that is proprietary to ABB Automation, Inc.

Members of the public who wish to attend should contact Keith Mortensen (NRC) at,(301) 41

_ L v,5/%

2915.

(D c p

P30006 g, g gg69Pi

,.o s 9908230199 990017 PDR TOPRP ENVC-E C

PDR

U

}

7 August 17, 1999 ts MEMORANDUM TO: Stuart A. Richards, Director Project Directorate IV & Decommissioning Division of Licensing Project Management Office of Nuclear Reactor Regulation -

- FROM:

- Stephen Dembek, Chief, Section 2 Project Directorate IV & Decommissi$ing nal signed by Division of Licensing Project Management Office of Nuclear Reactor Regulation

SUBJECT:

NOTICE OF MEETING WITH ABB-COMBUSTION ENGINEERING, INC.

- DATE & TIME:

Thursday, September 2,1999 8:30 a.m. - 4:30 p.m.

I

- LOCATION:

ABB Combustion Engineering

)

12300 Twinbrook Parkway Suite 330 Rockville, MD 20852 PURPOSE:

Present common qualified platform equipment qualification results. See the attached agenda for specific discuswon topics.

PARTICIPANTS:

Participants of the meeting from the NRC include members of the Office of Nuclear Reactor Regulation.

NBC 6BB Eric Lee Marty Ryan

. Keith Mortensen Ray Senechal '

Mark Stofko

Attachment:

Agenda cc: See next page.

Meetings between NRC technical staff and applicants or licensees are open for interested members of the public, petitioners, intervenors, or other parties to attend as observers pursuant to the " Commission Policy Statement on Staff Meetings Open to the Public," 59 Federal Register 48344,9/20/94. The session from 10:00 A.M. until 4:30 P.M. will be a closed meeting.

During this time, ABB will be presentin0.infcrmation tnat is proprietary to ABB Automation, Inc.

Membere of the public who wish to attend should contact Keith Mortensen (NRC) at (301) 415-2915.

I OFFICE PDIV-2/LA PDIV-2/SC NAME EPNon SDembek:rb DATE' 8/I'T/99 8/ O/9h OFFICIAL RECORD COPY DOCUMENT NAME: G:\\PDIV-2WBIMmtgno902.wpd

t

. Meeting with ABB-Combustion Engineering on September 2,1999 DISTRIBUTION.

EMail 1

. BSheron.

. JZwolinski/SBlack

' SRichards SDembek EPepon GTracy JStrosnider/RWessman JCalvo ELee.

KMortensen

. OPA (e-mail to OPA)

PMNS Hard Cooy

' Central FW PUBLIC '-

PDIV-2 Reading

.OGC ACRS-Receptionist (OWFN and TWFN) 4 I

5 a-

r --

ABB-Combustion Engineering, Inc.

. cc w/att:

- Mr. Charles B. Brinkman, Director Washington Operations j

ABB-Combustion Engineering, Inc.

i

~ 12300 Twinbrook Parkway, Suite 330 Rockville, Maryland 20852 I

i 1

I I

4 i

i

h MEETING AGENDA ABB COMMON QUALIFIED PLATFORM September 2,1999 Schedule: Note - The session from 10:00 A.M. until 4:30 P.M. will be a closed meeting. During this time, ABB will be presenting information that is proprietary to ABB Automation, Inc.

Time Subject ~

Presenter 8:30 Introductions / Review Agenda Mark Stofko 8:45 Project Status Mark Stofko 9:00 Review Status Keith Mortensen 9:15 Environmental Qualification (EQ)

Marty Ryan Methodology 10:00 Break 10:15 Seismic Test Marty Ryan Configuration / Photos

=

Test Data a

Test Results

=

Review Seismic Test Video

=

12:00 Lunch 1:00 Environmental Test Ray Senechal Configuration / Photos

=

Test Data

=

Test Results

=

2:30 Electromagnetic Interference Test Ray Senechal Configuration / Photos

=

Test Data

=

Test Results

=

4:00 EQ Documentation Marty Ryan Submittat

=

e

' Available for Review

=

4:15 Wrap Up Marty Ryan EQ Conclusions

=

Action items

=

4:30 Adjourn L