August 16, 1999 MEMORANDUM TO: Stu trt A. Richards, Dircctor Propct Dir:ctorate IV & Dscommissioning Division of Licensing Project Management Office of Nuclear Reactor Regulation FROM:

Stephen Dembek, Chief, Section 2 af Project Directorate IV & Decommissichmg Division of Licensing Project Management Office of Nuclear Reactor Regulation

SUBJECT:

WORKING LEVEL MEETING BETWEEN NRC AND THE ELECTRIC POWER RESEARCH INSTITUTE (EPRI)

DATE & TIME:

Tuesday, August 31,1999 9:45 AM - 4:15 PM LOCATION:

One White Flint North i

11555 Rockville Pike Rockville, MD Room O16-B-4 l

PURPOSE:

To resolve the open issues in the review of Topical Report TR-104965, "On-Line Monitoring for instrument Channel Performance." Specifically,

~j EPRI's strategy for on-line monitoring, plant implementation issues, and the proposed technical specifications will be discussed. See the attached i

agenda for specific discussion topics.

PARTICIPANTS:

Participants of the meeting from the NRC include members of the Office of Nuclear Reactor Regulation.

NRC EPRI E. Marinos R. Shankar, EPRI 99o8 J. Calvo D. Hooten, Carolina Power and Light Pg.?30 f[ 990g et al.

R. Rusaw, South Carolina Electric and Gas C

D K. Gross, Argonne National Lab g

NIEpgy E. Davis, Edan Engineering Project No. 669

Attachment:

Draft Agenda ec: See next page Meetings between NRC technical staff and applicants or licensees are open for interested members of the public, petitioners, intervenors, or other parties to attend as observers pursuant to the " Commission Policy Statement on Staff Meetings Open to the Public," 59 Federal Reaister 48344,9/20/94. Members of the public who wish to attend should contact S. V.

Athavale (NRC) at (301) 415-2974.

DISTRIBUTION:

l Hard Copv EMail WBeckner Docket File SCollins/RZimmerman TOuay PUBLIC BSheron/WKane JStrosnider/RWessman DMatthews/SNewberry p f c3 PDIV-2 R/F SAthavale OGC JCalvo GHolahan/TCollins ACRS c g O g-EMarinos GTracey, EDO RBarrett EPeyton Document Name: G:\\PDIV-2\\EPRI\\mtano831.wod OFFICE PDIV 2/SC PDIV-2/LA SDembekk EPeYoF ME FU W3M MF NAME' 8/ lo /99 9 *I4I i

DATE 8h19'9 l

W07sy

[

R 6 < g4 g gg OFFICIAL OFFICE COPY

I l

sSW4

,o 4

UNITED STATES i

,g j

NUCLEAR REGULATORY COMMISSION g

WASHINGTON, D.C. 20566-0001

'%......o August 16, 1999 MEMORANDUM TO: Stuart A. Richards, Director Project Directorate IV & Decommissioning Division of Licensing Project Management

)

Office of Nuclear Reactor Regulation

[(

FROM:

Stephen Dembek, Chief, Section 2 Project Directorate IV & Decommissioning Division of Licensing Project Management Office of Nuclear Reactor Regulation

SUBJECT:

WORKING LEVEL MEETING BETWEEN NRC AND THE ELECTRIC POWER RESEARCH INSTITUTE (EPRI)

DATE & TIME:

Tuesday, August 31,1999 9:45 AM - 4:15 PM LOCATION:

One White Flint North 11555 Rockville Pike Rockville, MD Room 016-B-4 PURPOSE:

To resolve the open issues in the review of Topical Report TR 104965, "On-Line Monitoring for Instrument Channel Performance." Specifically, EPRI's strategy for on-line monitoring, plant implementation issues, and the proposed technical specifications will be discussed. See the attached agenda for specific discussion topics.

PARTICIPANTS:

Participants of the meeting from the NRC include members of the Office of Nuclear Reactor Regulation.

MBQ EPR1 E. Marinos R. Shankar, EPRI l

J. Calvo D. Hooten, Carolina Power and Light et al.

R. Rusaw, South Carolina Electric and Gas l

K. Gross, Argonne National Lab E. Davis, Edan Engineering Project No. 669

Attachment:

Draft Agenda cc: See next page Meetings between NRC technical staff and applicants or licensees are open for interested members of the public, petitioners, intervenors, or other parties to attend as observers pursuant to the " Commission Policy Statement on Staff Meetings Open to the Public," 59 Federal Reoister 48344,9/20/94. Members of thi public who wish to attend should contact S. V.

Athavale (NRC) at (301) 415-2974.

Electric Power Research Institute cc:

Mr. Raymond C. Torok

' Project Manager, Nuclear Power Group Electric Power Research Institute Post Office Box 10412 Palo Alto, CA 94303-Mr. Gary L. Vine Senior Washington Representative Electric Power Research Institute 2000 L Street, N.W., Suite 805 Washington, DC 20036 Mr. Bindi Chexal Electric Power Research Institute Post Office Box 10412 Palo Alto, CA 94303 l

)

i.

r-I

' DRAFT AGENDA l

l 9:45

Introductions

10:00 Status of NRC Review NRC Staff 10:15 Utility Overview & Expectations Rooten & Rusaw l

10:30 EPRI Overview of On Line Monitoring Ramesh Meeting Scope i

Why are we here?

i-What did we do to get to this point?.

What do wo intend to do after NRC approval?

10:45 TR-104965 Discussion Davis Multivariate Statistical Estimating Technology Gross 12:45 LUNCH l

1:45 TR-104965 Review (cont.)

Davis l

RAI Disposition 2:45' Utility Application Instrumentation Calibration Monitoring Program at VC Summer Rusaw Multivariate Statistical Estimating Technology Applications Hooten 3:30 NRC Discussion f

3:45 Action items j

4:15 Adjourn l

1 l

Attachment