ML20210U249

From kanterella
Jump to navigation Jump to search
Notification of 860605 Meeting W/Util,Southern Co Svcs, Westinghouse & Bechtel in Bethesda,Md to Discuss Instrumentation Tech Spec
ML20210U249
Person / Time
Site: Vogtle  
Issue date: 05/29/1986
From: Mark Miller
Office of Nuclear Reactor Regulation
To: Youngblood B
Office of Nuclear Reactor Regulation
References
NUDOCS 8606020257
Download: ML20210U249 (2)


Text

e f0A Docket Nos.: 50-424 2 3 MAY 1986 and 50-425 MEMORANDUM FOR:

B. J. Youngblood, Director PWR Project Directorate #4 Division of PWR Licensing-A, NRR FROM:

Melanie A. Miller, Project Manager PWR Project Directorate #4 Division of PWR Licensing-A, NRR

SUBJECT:

NOTICE OF FORTHCOMING MEETING ON V0GTLE INSTRUMENTATION TECHNICAL SPECIFICATIONS DATE & TIME:

June 5, 1986 8:15 a.m. - 5:00 p.m.

LOCATION:

Phillips Building Room P-422 7920 Norfolk Avenue Bethesda, Maryland PURPOSE:

To discuss the Vogtle Instrurrentation Technical Specification PARTICIPANTS:

NRC WESTINGHOUSE Diller K. Dasolke R. Jansen SOUTHERN COMPANY SERVICES BECHTEL J. Stringfellow S. Mahler B. George R. Schilling GEORGIA POWER COMPANY T. Wendt J. Swartzwelder P. Kochery

}j fVh J. Sutphin

\\s\\

Melanie A. Miller, Project Manager PWR Project Directorate #4 Division of PWR Licensing-A, NRR cc: See next page

(

[

PWR#4/DPWR-A PWRf4/DPWR-A M MMiller/mac BJYoungblood 05/ g /86 05/ g /86

(

86060202D7 860529 PDR ADOCK 05000424 A

PDR W

y-Mr. R. E. Conway Georgia Power Company Vogtle Electric Generating Plant cc:

Mr. L. T. Gucwa Resident Inspector Chief Nuclear Engineer Nuclear Regulatory Commission Georgia Power Company P. O. Box 572 P.O. Box 4545 Waynesboro, Georgia 30830 Atlanta, Georgia 30302 Mr. Ruble A. Thomas Deppish Kirkland, III, Counsel Vice President - Licensing Office of the Consumers' Utility Vogtle Project Council Georgia Power Company /

Suite 225 Southern Company Services, Inc.

32 Peachtree Street, N.W.

P.O. Box 2625 Atlanta, Georgia 30303 Birmingham, Alabama 35202 James E. Joiner Mr. Donald O. Foster Troutman, Sanders, Lockerman, Vice President & Project General Manager

& Ashmore Georgia Power Company Candler Building Post Office Box 299A, Route 2 127 Peachtree Street, N.E.

Waynesboro, Georgia 30830 Atlanta, Georgia 30303 Douglas C. Teper Mr. J. A. Bailey Georgians Against Nuclear Energy Project Licensing Manager 1253 Lenox Circle Southern Company Services, Inc.

Atlanta, Georgia 30306 P.O. Box 2625 Birmingham, Alabama 35202 Billie Pirner Garde Citizens Clinic Director Ernest L. Blake, Jr.

Government Accountability Project Bruce W. Churchill, Esq.

303 10th Street Shaw, Pittman, Potts and Trowbridge Augusta, Georgia 30901 1800 M Street, N.W.

Washington, D. C.

20036 Mr. G. Bockhold, Jr.

Vogtle Plant Manager Georgia Power Company Route 2, Box 299-A Waynesboro, Georgia 30830 Regional Administrator, Region II U.S. Nuclear Regulatory Connission 101 Marietta Street, N.W., Suite 2900 Atlanta, Georgia 30323 w