ML20210U047
| ML20210U047 | |
| Person / Time | |
|---|---|
| Site: | 07001426 |
| Issue date: | 01/07/1999 |
| From: | Mclaughlin J TRANSNUCLEAR, INC. |
| To: | Bennington G NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| References | |
| TNY-98132-6, NUDOCS 9908190216 | |
| Download: ML20210U047 (2) | |
Text
2LGMW-16@ N-5:44
%%@GCsLEAR, INC.
914 347 5170 P.01/02 0( & -(
0-0$
N TRANSNUCLEAR, INC.
January 7,1999 i
Post-h* Fax Note 7671 0** i l 'y qq l[aM 7-
]
Gloria Benmnbton
""Umn IAc tauchli n v
Mrs. Gloria Bennington cuoem. g g p g coTMN Division of Safeguards and Transportation Phm0 8 91 347-50/A enwen U.S. Nuclear Regulatory Commission Fax 9 e.g g
gg Washington, DC 20555 k:
Transnuclear reference: TNY 98132-6 Advance nouncation for an import shipment of nuclear material from countries that I
are not party to the Convention on the Physical Protection of Nuclear Material This letter constitutes Transnuclear Inc.'s advance notification to the USNRC in compliance j
with the requirements as outlined in 10 CFR 73.74(a)(1)(2) for an import shipment of low strategic significance material from Countries that are not party to the Convention on the Physical Protection of Nuclear Material.
Details of this shipment as required in 10 CFR 73.74(a)(3) are as follows:
73.74(a)(3)(i) Data:
Importer of Record Receiving Facility COGEMA, Inc.
Westinghouse Nuclcar Fuels Division 7401 Wisconsin Avenue 5801 Bluff Road Bethesda, MD 20814 Columbia, SC 29209 301/986-8585 803n76-2610 Shipping Facility Carriers COGEMA Pierrelatte Atlantic Container Lines B.P.16 50 Cragwood Road 26700 Pierrelatte, France So. Plainfield, NJ 07080
~
33 7550 4000 908/668-5556 Transport Coordinator AND Transnuclear, Inc.
Advanced Distribution Systems Four Skyline Drive 2329 So. Hayden Road 9
Hawthome, NY 10532 Spokane, WA 99224 914/347-2345 1-800-756-0223 9908190216 990107 PDR ADOCK 07001426 C
PDR 190031 D
FOUR SKYLINE DRIVE + HAWTHORNE, NEW YORK 10532-2176 TELEPHONE: 914-347 2345. FAX: 914-347-2346
2(CRW-mkt IDC3 WKXsGWgC% ENC.
914 347 5170 P.02/02 1
^-
o/oeg._j Page 2 of 2 January 7,1999 TNY 98132-6 73.74(a)(3)(ii) Data: Physical description of shipment:
Five model 30B cylinders inside overpacks containing:
RQ, URANIUM HEXAFLUORIDE, FISSILE (conmining more than 1% U235), 7, UN2977, Radioactive Material (U235,U238) solid, UF6. Approximate UP6 weight: 11,385 kgs.
J Approximate U weight: 7,698 kgs enriched to max. 4.40%. Approximate weight U235:
l 339 kgs 73.74(a)(3)(iii)(iv)(v) Data:
MODE ORIGIN (0), TRANSFER (T),
ROUTE DATE/ TIME OF ARRIVAL COUNTRY /ENROUTE(C/E)&
(A) & DEPARTURE (D) AT DESTINATION (D) POINTS EACH POINT Rail Pierrelatte, FRANCE standard rail (D)
March 29,1999 0800 - 1800 hours0.0208 days <br />0.5 hours <br />0.00298 weeks <br />6.849e-4 months <br />
{
Antwerp, BELGIUM (A)
March 30,1999 Ocean.
standard ocean 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> M. c<wimor-(D)
March 31,1999 Liverpool, ENGIAND (A/D) April 3,1999 j
0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Halifax, CANADA (A/D) April 11,1999 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Port Elizabeth, NJ (A/D) April 13,1999 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Baltimore, MD (A/D) April 15,1999 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Portsmouth, VA (A)
April 16,1999 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Arrival at the receiving facility is estimated to be between 0700 hours0.0081 days <br />0.194 hours <br />0.00116 weeks <br />2.6635e-4 months <br /> and 0900 hours0.0104 days <br />0.25 hours <br />0.00149 weeks <br />3.4245e-4 months <br /> on April 20 - 21, 1999.
This shipment will meet the levels of physical protection specified in Appendix E (Annex I).
Yours tmly, 00%WhM (Joan McLaughlin Traffic Coordinator TOTAL P.02