Confirms 970902 Telcon Re Corrective Actions Taken by W Prior to Restart of Operations in Pellet Mfg Area on Second Shift,On 970902
ML20210T430
Person / Time
Site: Westinghouse
Issue date: 09/03/1997
From: Allen J
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To: Dan Collins
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
CON-NRC-97-042, CON-NRC-97-42 NUDOCS 9709150120
Download: ML20210T430 (3)


Text

__

Westinghouse Commercial Nuclear Drawer R Electric Corporation Fuel Division fssi'sYsE*

NRC-97-042 September 3,' 1997 U. S. Nuclear Regulatory Commission

' ATTN: Mr. D.-M. Collins, Acting Director Nuclear Materials Safety Region II Atlanta Federal Center I

61 Forsyth Street, SW, Suite 23T85 Atlanta, GA 30303

Dear Mr. Collins:

REF: Corrective Actions for Restart of the Westinghouse CNFD-Columbia Plant Pellet Manufacturing Area This letter confirms the September 2,1997 telephone conversatiott aetween you and some

-members of my Staff, and documents the corrective actions taken by Westinghouse prior to the restart of operations in our Pellet Manufacturing Area on second shift, Tuesday, September 2, _

-1997.

The specific actions taken to bring both the granulator hoppers and moisture drop-out tanks into full compliance with our SNM license requirements are listed separately below:

, GRANULATOR HOPPER The nuclear safety analyses (CALCNOTES) were completed, and approved following the e

conduct of an independent technical review.

The criticality safety evaluation (CSE) was completed, and approved following the conduct e-of an independent technical revkw.

The hoppers on all pellet lines were visually inspected ~ to verify the presence of volume

- reducers.

The plexiglass viewports on all hoppers were replaced, to improve visibility, and sealed.

.9709150120 970903 PDR ADOCK 07001151; C

3

,O The Mstkybwse Commerch/NuclearfuelDivikbn - Wh.7erofthe 1998M&v/mBalchpeNatb1a/Qialtykwd Gd7J

4-LNI(C-97-042

' Page 2 c

September 3,1997 Relevant chemical operating procedures (CUP's) were revised, approved and reissued.

Training was conducted for Chemical Operations (Pellet Area) personnel to familiarize them with relevant procedural changes, The powder " feed prep stackup" system, including the granulator hopper, on each pellet e

line was " walked down" to verify that the "as-built" field installation was in agreement with the design / safety basis documented in the respective CSE.

MOISTURE DROP-OUT TANKS The nuclear safety analyses (CALCNOTES) were completed, and approved following the e

conduct of independent technical reviews.

The criticality safety evaluation (CSE) was completed, and appmved following the conduct e

of an independent technical review.

4 e Procedures ROP-05-062 (gramma surveys) and RA-108 (safety significant interlocks) were revised, approved and reissued.

The Maintenance MAPCON system was updated to reflect the inclusion of the tank conductivity probes and associated interlocks as safety significant interlocks.

The conductivity probes and associated interlocks on each tank were tested to confirm functionality.

. The conductivity probe " tap" lines and drain line on each pellet line tank were visually inspected to confirm the absence of any SNM accumulations.

The tanks on all pellet lines were physically cleaned to remove all SNM accumulations.

Training was conducted for Chemical Operations (Pellet Area) and Regulatory Engineering e

& Operations, personnel to familiarize them with relevant procedural changes.

The moisture drop-out tank system on each pellet line was " walked down" to verify that the "as-built" field installation was in agreement with the design / safety basis documented in the respective CSE.

u

o

, NI(C-97-042 Page 3 September 3,1997 If you should have any questions, or need additional information regarding this matter, please telephone Mr. Wilbur Goodwin of my Staff at (803 776-2610, Extension 3282.

Sincerely, WESTINGIIOUSE ELECTRIC CORPORATION k U. Mew

. B. Allen, Manager Columbia Plant

(