AUG 2 61975 R. C. DeYotung, Assistant Director for LWR's, Group 1, RL REVIEW OF REVISED DESIGN SNOW LOAD FOR EITREME ENVIRONMENTAL CONDITION PLANT MAME: WPPSS Nuclear Power Project No. 3 - Units 3 & 5 LICENSING STAGE: CP DOCKET NUMBER: 50-508 & 50-509 MILE 3 TONE NO.: 24-32 RESF0tfSIBLE BRANCH: LWR 1-3 REQUESTED COMPLETION DATE: August 29, 1975 APPLICANTS RESPONSE DATE NECESSARY FOR NEXT ACTION FLANNED ON PROJECT: N/A DESCRIPTION OF RESPONSE: None REVIEW STATUS: Meteorology Section, (SAB) - Complete The letter transmitting the meteorology section input to the WPPSS Nuclear Project No. 3 SER, dated June 27, 1975, noted that the applicant had not demonstrated the adequacy of the design snow weight for the extreme environmental condition. This conclusion was based on the applicant's statement that the weight of the 48-hour Probable Maximum Winter Precipitation for the site area was in excess of the 50 pounds / squat a foot design snow load proposed fer the roofs of safety related structures.
l In Amendment No. 20 of the PSAR dated July 1975, in reponse to the i
staff's position, the 6pplicant has revised the design bases snow weight used for the extreme environmental condition to 80 pounds / square foot. This value is considered to be sufficient for the site area.
This review was prepared by R. Korraaiewicz, Site Analysis Branch, TR.
l f
AWnm :d-Harold R. Denton, Assistant Director
)
for Site Safety Division of Technical Review Office of Nuclear Reactor Regulation fa S DISTRIBUTION:
sd l
DOCKET FILES NRR RDG cc: See next page SAB RDG TR:SAB $_..%.
TR:SpS TR:AD/SS o,,,,,,
RKornasiewicz ee WGamm EDenton
- 8//f7f5 8/ R f /75 8/
/75
~~
'8/ 2. 5 /75 Foran ABCrSl4 (Rev. 9 53) AECM 0240 W u. s. novsaguamt enintime orreces i,re.sas.:ee 8605290808 750826 PDR ADOCK 05000508 E
6 e:
B R. C. DeYoung AUG
- C hP4 cc: w/o enc 1:
j R. Boyd W. MeDonald J. Feesarella I
ec: w/amel*
S. Banauer
/
R. Betammen
/
j E. Dentoa SS Branch Chiefs O. Parr P. O'Reilly R. Kornasiewicz J. Goll R. Elecker D. Eisenhut S. Varga 3
C P
a b
s
?
S* F M >
suaaaana >
DaTS &
Foran ABC 318 (Rev,9 53) A2CM 0240 TF u. o. eevs maass*.T rasatme OPP'c s* s*7*-eae.see
.p..
p
%.,y g.
g.
.,7
.g,.,,,,-.
_.y.,