g,,,cne *4M 00LKETED a

usHRC 1

86 0CT -6 P5:08 UNITED STATES OF AMERICA 2

NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC S$FETY AND LICENSING 0FFKE 0 3

4 5

)

Docket Nos. 50-275 In the Matter of

)

50-323 -dM 6

-)

PACIFIC GAS AND ELECTRIC COMPANY )

(Reracking of Spent Fuel Pools) 7

)

(Diablo Canyon Nuclear Power

)

8 Plant Units 1 and 2)

)

)

9 10 LICENSEE PACIFIC GAS AND ELECTRIC COMPANY'S ANSWERS TO FIRST SET OF INTERROGATORIES 11 0F THE SAN LUIS OBISPO MOTHERS FOR PEACE, DATED SEPTEMBER 15. 1986 12 33 14 INTERROGATORY NO. 1:

15 16 Identify and supply all documents, including but not limited to 17 reports, analyses, meeting summaries, memorandums, and portions thereof, 18 relied upon to evaluate the alternatives to high density re-racking of the 19 spent fuel pools at Diablo Canyon nuclear plant.

20 21 RESPONSE TO INTERROGATORY NO. 1:

22 23 PGandE's evaluation of alternatives was based on an understanding of i

24 the existing industry practice and, in general, the currently available 25 technology for the storage of spent fuel. This understanding was derived from 26 a review of the existing literature on reracking amendments submitted by other 8610080258 861003 PDR ADOCK 05000275 O

PDR

1 utilities which had been previously filed with and issued by the NRC, generic 2

research documentation generated by the federal government pursuant to the 3

Nuclear Maste Policy Act of 1982, and other industry sources discussing spent 4

fuel storage alternatives. These sources also included periodicals of the 5

nuclear industry, technical reports issued by the NRC, and other documents 6

related to storage of spent fuel. While these sources provided a general 7

understanding of the available alternatives, PGandE performed a specific 8

review of alternatives for Diablo Canyon. Since the evaluation was performed 9

with this basic understanding, it was deemed not necessary to document each 10 aspect of the evaluation; therefore, it is not possible to either identify or 11 supply all of the reference documentation. However, specific documents that 12 are available and which are directly related to the evaluation of alternatives 13 at Diablo Canyon are listed on page 4 and attached to this response.

14 15 16 INTERROGATORY NO. 2:

17 18 Identify and supply all information and documents relied upon to 19 evaluate dry cask on-site storage as an alternativo to high density 20 re-racking.

21 22 RESPONFE TO INTERROGATORY NO. 2:

23 24 See response to Interrogatory No. 1.

25

///

26

///

I ;

1 1 _. -,. -__. _ _. _.. - _ _ _ _.. _. _. _ _ _. _.. _.. -. _. -.. _ _ _.. _...... _.... _. _ _ _ _ _ _ _ _ _ _ _ _ _ _...... _ _. _ -

1 1

INTERROGATORY NO. 3:

2 3

Supply the cost-benefit assessment done by PGandE on re-racking and 4

alternatives to it.

(referred to in Rerackina of Soent Fuel Pools. Diablo 5

Canyon Units 1 and 2. Seotember.1985) 6 7

RESPONSE TO INTERROGATORY NO. 3:

8 9

See response to Interrogatory No. 1.

10

///

11

///

12

///

13

///

14

///

15

///

16

///

17

///

18

///

19

///

l 20

///

l 21

///

22

///

23

///

l 24

///

25

///

26

///

l -

.e 1

Documents Produced for Interroaatories 1. 2 and 3 2

1.

Distribution of Job Estimate, PGandE NPG-041, February 14, 1984 3

4 2.

PGandE Memorandum, J. D. Shiffer to J. O. Schuyler, " Question on Dry Cask Storage," Letter No. 83/21-14; May 21, 1983, 2 pages 5

6 3.

Draft PGandE Report on Spent Fuel Rack Addition Description and Safety Analysis, November 1979; with markups 7

8 4.

PGandE Memorandum on Vendor Presentation on Spent Fuel Storage and Transport, August 4, 1981 9

10 5.

Job Estimate, Replace Spent Fuel Storage Racks with High Density Racks, PGandE NPG-041, 1982; with draft 11 12 6.

PGandE Project / Activity Justification for Spent Fuel Modification, October 6, 1983.

13 14 7.

Draft Proposal for Spent Fuel Modifications, PGandE, October 6,1983.

15 8.

Economics of At-Reactor Spent Fuel Storage Alternatives, E. T. Merrill 16 and J. F. Fletcher, April 1983 17 9.

PGandE Memorandum on Spent Fuel Rack Modification, High-Density Racks, GM 18 Cost Estimate NPG-041, October 21, 1983 19

10. PGandE Job Estimates submitted to the Board of Directors for review, l

20 Spent Fuel Rack Modifications, February 15, 1984 21

///

22

///

23

///

i 24

///

l 25

///

26

///,

,,,my

. m

1 FIRST SET OF INTERROGATORIES PROPOUNDED TO PACIFIC GAS AND ELECTRIC COMPANY 2

BY SAN LUIS OBISP0 MOTHERS FOR PEACE 3

4 5

I have assisted in preparing the answers to Interrogatory Nos. 1, 2, 6

and 3.

Said answers are true and' correct to the best of my 7

knowledge and belief.

8 9

10

/4Y 12 S /RYANT H. GIFFIN W 13 14 15 16 17 18 Subscribed and sworn to 19 before me this 3rd day 20 of October, 1986 21

=& 0 22 C

7/

23 Nancy J. Lemaster, Notary Public SEAL in and for the City and County 24 of San Francisco, State of California 25 26 My Commission expires April 27, 1990 PjrtitintinteWIu'titttlittlilitettlitittittitinlitIHit!!Jftllfill!!!!..ll!

5 OI FICIAL SEAL

$)

NANCY J. LEMASTER a

5

.4 NOTARt PUBUC CAltf0dNIA y 3 de/ CITY 4 COUNTY OF SAN FRANCliC0g

~

l My Commession Empires Apnl 27,1990 $

., _ 'lli.l.it'?ttittlitillett!Ilust!F lil-a m'1

1 FIRST SET OF INTERROGATORIES PROPOUNDED TO PACIFIC GAS AND ELECTRIC COMPANY 2

BY SAN LUIS OBISPO NOTHERS FOR PEACE 3

4 5

I have assisted in preparing the answers to Interrogatory Nos. 1, 2, 6

and 3.

Said answers are true and. correct to the best of my 7

knowledge and belief.

8 9

10 t

1X&Os 12 E0HARD C. CONNELL III 13 14 15 16 17 18 Subscribed and sworn to 19 before me this 3rd day 20 of October, 1986 21 22 23 Na y J. Lemaster, Tdfary PubH c in and for the City and County 24 of San Francisco, State of SEAL California 25 26 My Commission expires April 27, 1990 (mtlNttittl!!!!!!!IlittiliitttttfitglinHINI, E

OFFICIAL SEAL M M4 NANCY J. LEMASTER l j7t<j'4 NOTARY PUBUC.CAUFORNIA CITY & COUNTY OF SAN f RANCISCO g

My Commission Expires Apnl 27,1990 ut tinntimel

'Nw va-'--

e

-cr-

- _--,, _i- _,

[

, ge== rr*8'6 DOLKEILC UWRC UNITED STATES OF AMERICA

'86 (ET -6 P5.08 NUCLEAR REGULATORY COMISSION

{0CET !$ib f

I BRANCH

)

Docket Nos. 50-275 In the Matter of

)

50-323

)

PACIFIC GAS AND ELECTRIC COMPANY )

(Reracking of Spent Fuel Pools)

)

j (Diablo Canyon Nuclear Power

)

Plant Units 1 and 2)

)

)

1 CERTIFICATE OF SERVICE I

I hereby certify that on October 3,1986, copies of the following documents in the above-captioned proceeding have been served on the following by deposit in the United States mail, first class:

(1) LICENSEE PACIFIC GAS AND ELECTRIC COMPANY'S ANSHERS TO FIRST SET OF INTERROGATORIES OF THE SAN LUIS i

OBISPO MOTHERS FOR PEACE, DATED SEPTEMBER 15, 1986; (2) LICENSEE PACIFIC GAS AND ELECTRIC COMPANY'S ANSHERS TO FIRST SET OF INTERROGATORIES OF CONSlI1ERS ORGANIZED FOR DEFENSE OF ENVIRONMENTAL SAFETY, DATED SEPTEMBER 16, 1986; and (3) LICENSEE PACIFIC GAS AND ELECTRIC COMPANY'S ANSHERS TO FIRST SET OF INTERROGATORIES OF THE SIERRA CLUB, DATED SEPTEMBER 15, 1986. The production of documents associated with the interrogatories have been serveo on only j

those indicated by an asterisk.

4 B. Paul Cotter, Jr., Chairman Docketing and Service Branch Administrative Judge Office of the Secretary t

i Atomic Safety and Licensing U.S. Nuclear Regulatory Commission Board Panel Hashington DC 20555 U.S. Nuclear Regulatory Commission 4350 East West Highway 4th Floor Bethesda MD 20814 l

Glenn 0. Bright Lawrence Chandler, Esq.*

l Administrative Judge Henry J. McGurren, Esq.

l Atomic Safety and Licensing Office of Executive Legal Director U.S. Nuclear egulatory Commission r

Board Panel U.S. Nuclear Regulatory Commission Maryland National Bank Building 4350 East West Highway 4th Flocr Room 9604 Bethesda MD 20814 7735 Old Georgetown Road Bethesda MD 20814 Dr. Jerry Harbour Lewis Shollenberger Administrative Judge Regional Counsel Atomic Safety and Licensing U.S. Nuclear Regulatory Commission Board Panel Region V U.S. Nuclear Regulatory Commission 1450 Maria Lane, Suite 210 4350 East West Highway 4th Floor Halnut Creek CA 94596 Bethesda MD 20814

a Diablo Canyon Service List Atomic Safety and Licensing Diane M. Grueneich*

Board Panel Grueneich & Lowry U.S. Nuclear Regulatory Commission 345 Franklin Street Hashington DC _20555 San Francisco CA 94102 Atomic Safety and Licensing Jacquelyn Wheeler Appeal Board Panel 2455 Leona Street U.S. Nuclear Regulatory Commission San Luis Obispo CA 93401 Washington DC 20555 Mr. Lee M. Gustafson C.O.D.E.S.

Pacific Gas and Electric Company 731 Pacific Street Suite #42 1726 M Street NH Suite 1100 San Luis Obispo CA 93401 Washington DC 20036-4502 Managing Editor Janice E. Kerr, Esq.

San Luis Obisoo County Public Utilities Commission Telearam-Tribune 5246 State Building 1321 Johnson Avenue 350 McAllister Street San Luis Obispo CA 93406 San Francisco CA 94102 Richard E. Blankenburg Nancy Culver, Co-publisher 192 Luneta Street Wayne A. Soroyan, News Reporter San Luis Obispo CA 93401 South County Publishing Company P. O. Box 460 Arroyo Grande CA 93420 Dr. Richard Ferguson*

Vice-Chairman Sierra Club Rocky Canyon Star Route Creston CA 93432 kA V

i Richard F. Locke Pacific Gas and Electric Company 77 Beale Street. 31st Floor San Francisco, CA 94106 Dated at San Francisco, California, this 3rd day of October,1986.,

[

_ -,,.. _,.., _. _.., _ _ _ _..