September 2,1997 Mr. Tom Matula Mall Stop 06F18 Transportation, Safety & Inspection liranch Spent Fuel Pro. lect Ollice, NMSS U. S. Nuclear Regulatory Commission Washington D.C. 20555 FAX No: 301415 8555
Reference:
Confirmatory Action Letter No.97 7 006, dated June 24,1997.
Dear Tom:
Attached please find the independent QA Audit Report submitted by Mr. Cassius L. Tillman of Quahty Management Suppo;t, Inc. Part B of the report identifies the root causes and includes recommendations for improvements. This will be used to supplement SPEC's audit report and the NRC's inspection repon to develop the Phase ill Corrective Action Plan.
Please note that the completion of the independent audit satisfies item 5 of NRC Corrective Action Letter No. 97 7 006. We have completed all of the items in the CAL but we are not yet requesting for the NRC to close the CAL since we are still implementing Phase 11 corrective actions. The Phase ill Plars will be submitted to the NRC by September 15,1997.
Sine if/
R. D. (Donny) Dichar -
President Enclosed:
QA Audit Report dated August 25,1997, Quality Management Support,Inc.
h t
ma.9 mci 9709110019 97o902
{DR ADOCK 07100102; PDR lllil,lli101iljll,WOllllll 100010 Nou>ce Production & Equipment Co., Inc.
.l 113 Teal Street St. Rose, LA 70087 9691 Phone 504/464 9471 Telex 460156 FA.X 504/467 7685
E.
MS QUAUTY MANAGEMENT SUPPORT,INC.
August 28,1997 Mr. George Moran Source Production nnd Equipment 113 Teal S;reet St. Rose, Louisiana 70087-9691 t
Dear George:
d On August 19 and 25,1997 Quality Management Support visited your facility and performed a review / evaluation of the current status of SPEC's existing qua.lity system and performed a root cause analysis.
l The r view was broken into two areas. The report follows this format:
A)
A uview and evalue.be of the corrective action taken with regard to Phase 1.
B) 1)
A review of the quality system to identify the baseline (root cause) of the current problems and conditions of the quality system.
2)
To make recommendations for the improvement of the quality system based on this review / root cause analysis.
Thank you for the opportunity to work vith you and the other personnel at S.P.E.C. I hope this report is beneficial to the quality effort at S.P.E.C.
Ifin '.he future we can be of any additional senice, please do not hesitate to call.
Best regards, Crasius L. Tillman, IV President c
(504) 482-7900 P. O. Box 9572 Metairb, Louisiana 70055 Fax (504) 482-9888 n
L.
MS OUAUTY MANAGEMENT SUPPORT Onnlity System Review / Evaluation Review Dates: August 19 and 25,1997 Lead Auditor: Cassius L. Tillman, IV, Quality Management Support, Inc.
Source Pioduction and Equ pment Company, Inc.
St. Rose Facility EarLA i
A review of each corrective action to SPEC findings and NRC Inspection Observation wa ; made, associated new procedures, changed procedures, training records, and other types of documentation were reviewed. Corrective Action 15 A through 36 A were reviewed as follows:
15A Reviewed Procedure 1.1 and the Engineering change orders system 16A Reviewed revised shop order travelers for Asm Lock Assembly Spec 150 Main Traveler both contained print ID and revision level from quality with a comparison and documentation of the print used.
17A See 15A ISA All non in-process travelers have been removed from the shop floor. Ken Joslyn issues work orders for production, tlic Quality Depanment ensures latest edition of shop traveler issuance and print control. V'ork Orders released to Production after Quality Department sign off.
19A See above, a variety of re-issued travelers were reviewed. All had General Manager sign off as well es Quality Department sign off.
20A A review of documentation on the shop floor contained no " Sketches" Sketches have been removed from operational existence.
Sketch Spec 150 S tube cut off dated 10-4-95 stored in non-production file drawer are red lined "/" through text marked obsolete.
(504)482-7900 P. O. Box 9572 Metairie, Lou %iana 70055
=
Fax (504) 482-9888
+
QCUALITY MAN MS SPEC Review Page 2.
21A Reviewed revised form QA 7.8 for shield 22A Reviewed training / retraining record ofJuly 18,1997 and revised traveler 150008 23A Preliminary status has been made obsolete. All drawings require the same review and approval process for control. Changes are controlled through the use of the Engineering Change Request System.
24A Calipers reviewed In use in production areas were found to have the appropriate current calibration sticker, i.e. s/n 0034930 Mitatoyo. Training records of 7-14 97 of QA personnel to Calibration and Control of Calipers reviewed 25A Reviewed revised Standard Operating Procedure 6.10. " Survey Meter Calibration" 26A Reviewed document control procedure 1.10, " Engineering Document Control" paragraph 7.4 dealing with red line changes to engineering documents. Red Line ability has not been eliminated from the system, but controls are more defmitive.
27A Reviewed Ship Traveler 150008, " Casting Depleted Uranium Shield ', Revision 2 July 18, 1997. Reviewed file for Spec 150 Camera s/n 0496, Certificate of Compliance from Manufacturing Scienen Corporation 804 Kerr Hollow Road Oak Ridge, TN 37830 was readily available.
28A Drawing books located at three different locations were reviewed against the most current revision of the Master list. The latest revisions were available.
29A Reviewed newly generated procedures for SPEC 150 procedure #1.30," Document Distribution", Revision 0, 7-18-97, 30A Revised Training records:
The majority ofpersonnel were trained on July 16,1997. A make up training session was provided for three people on July 24,1997. Traveler Training was provided on 7-17-97.
31A Reviewed new shop order procedure #3.05, " Shop Orders", Revision 0, 7-18-97.
Reviewed shop orders and shop order log.
f 4
MS LliY MANAGEMENT SUPDORY. WC SPEC Review Page 3.
32A Reviewed documentation of reinspection of parts in questions.
33A Reviewed newly generated form titled Inspection / Fabrication Documentation Audit Checklist. Checklist will be utilized to verify completion of all required process steps, and inspections and test requires QA Sign off.
34A A nonconformance room, locked, complete with file cabinets for records and storage for nonconforming material has been established. A review ofitems in nonconformance area was performed. All items had appropriate marking red tags and copies of pertinent Nonconformance Reports attached.
35A Reviewed newly generated form and procedure QA 18.1 " Spot Audits" and records of those " Spot Audits" performed. Limited number to date due to the implementation time cycle.
36A Reviewed procedures for Engineering Change Orders 3.0 QAM Section 3 Scope -
Prototype and production drawing will require the same nature and extent of review and approval.
Completion of the corrective actions associated with Phase I have been verified. Evaluation of the effectiveness of these actions will require the passing of time and utilization of the system.
Part B No one single element of the quality system, nor one single event is responsible for the lapses in the current quality system at SPEC Our root cause analysis uncovered a number of contributing factors, which exclusively may have minor effect on the quali'y system, but collectively have had a major negative impact.
Five major root causes have been identified for improvement:
1)
Quality System Documera mr and Document Control 2)
Qualification and Training j
Q*MS SPEC Review Page 4.
3)
Control and Calibration ofInspection, Measuring and Test Equipment 4)
Nonconformance Reponing 5)
Corrective Action Systern.
.4 Ounlity System Documentation and Document Control The current quality system documentation is disjointed with little flow from the Quality Program Manual to Quality Assurance Manual to the bulk of the Quality System which is presented in the Standard Operating Procedure Manual. In some cases there is no continuity between requirements of one manual and those of another. Multiple authors over time have been a contributing factor to this problem.
In some areas, i.e. corrective action, the requirements of when to use and how to use have not been well dermed.
Recommendation:
A total review of and rewrite of the quality system documentation with emphasis on:
Definition of requirements Consistency of requirements A methodology to connect the multi-tiered quality system to provide a logical flow from least specific document (Quality System Manual) to the most specific document (Work Instructions).
Review / rewrite of area specific portions of the manual and procedures should be done in concert with the personnel who perform this work. Their involvement in the process will help with acceptance of and ownership of the quality system.
Ounlification and Training The current system for defming and documenting qualification requirements and training needs is inadequate. Qualification requirements are not well 6 fined. Required training for 1
MS SPEC Review OUAUTV MANAGEVENT SUPPORT. INC Page 5.
personnel has not been established. Training is not " Evergreen" you can't do it once and expect it to last forever.
Recommendation:
Rewrite the appropriate Quality Manual Section to derme:
Method of qualification of personnel for each defined job classification.
Training required:
Quality System Training Job Specific Training Establish methods, i.e. checklist, to document training required and training completed.
Training attendance records need to be revised to include at a minimum:
Detailed description of training provided Date of training Duration of training Name of person providing the training List of attendees If training to "all Personnel" is identified, the syaem has to have proper checks and balances to assure that all personnel receive the required training.
A training schedule needs to be established and published.
As needed training needs to be identified and provided.
Control and Calibration ofInspection. Mensuring and Test Equipment The calibration system needs to be reviewed and revised to more thoroughly detail the requirements for calibration, documentation and traceability back to NIST for standards used.
Recommendation:
Equipment calibration records should be expanded to include an identification of which standard was used in the calibration.
The procedure need to be reviewed / revised for calibration of standard used.
QOVAuf f MS SPEC Review Page 6.
The procedure 7.22 for the calibration ofcalipers/ micrometers be reviewed and revised to ensure full scale calibration.
Purchasing documents ofinspection, measuring, and test equipment (including standards) sent out for calibration should include a paragraph similar to attachment 1.
Nonconformance Reporting Nonconformances are currently being well documented at the time of occurrence. The systems weakness seems to be in the timely review and disposition of the nonconforming material. The system also lacks controls to ensure evaluation of repetitive nonconformances.
Recommendations:
That the nonconformance requirements in the quality manual be expanded to include a requirement for timely review and disposition of nonconforming material.
At a minimum, swice yearly reviews ofnonconformances be performed and documented by the Quality hianager, Production hianager, and the General hianager to evaluate and identify repetitive trends. The corrective action system should be utilized as the vehicle for documentation.
Procedures should be reviewedhuised to ensure defined requirements can be met, i.e.
sign otTby the President on all scrap dispositions.
Corrective Action _
The corrective action system as currently defined and implemented is inadequate and provides little value added.
Recommendation:
hianual section and appropriate procedures associated with Corrective Action Requests should be revised / rewritten and greatly strengthened. The requirements ofISO 9000 element 4.14, " Corrective and Preventive Action" would provide a good basic guideline for this section.
Corrective Action should be generated to address audit findings.
OUAUTY WANAGEMENT SUPPORT. INC SPEC Review Page 7.
That the SPEC Failure Reporting program be tied to, become part of the Corrective Action System.
A method for the evaluation of the efTectiveness of corrective action taken be established and utilized.
The corrective action reporting form be expanded to address action steps taken. Items which cause the generation of a corrective action report usually do not have a simple one line answer. Normally multiple action need to be taken and traced. Performance and completion is often by different people with different close out dates.
The protdems with SPEC Quality System are not limited to the five items listed above. The philosophy of quality, including the discipline and consistency required by a quality system, needs to be reintroduced throughout all areas of the facility including all personnel involved.
l On a positive note, during my two day visit to the SPEC facility, SPEC personnel's positive attitudes stood out.
Positives l
The Shop Orderffraveler System (already in the works) with checks and balances to ensure only the latest revision of the correct print is utilized.
All personnel interviewed during my two day visit were interested and expressed a desire to do it the right/best way.
Management personnel expressed a desire to not only correct the problems but to have this experience be value added and the end results be a better quality system to work with and a better final product.
The SPEC Equipment Fail Reporting System is very good. Formally connecting it to the Corrective Action would make it even better.
The Spot Audit Process provides an effective means to involve all levels of management and all departments in the QA system.
VIS d to,,,c,,,,,,,,,,,,
SPEC Review Page 8.
Challenges to meet Implementation ofrewritten update, stronger quality system throughout the facility.
Ensuring ownership of the Quality System by all SPEC personnel.
Maintaining long term focus on and attention to the Quilky System.
--.- J
4 Print commant on All P 0's: N r
Cntrl Comment: 053 Al f_*PURNISH DETAIT.un CALTBRATION ev%TIFICATE D.2
_ NETCR INCLUDE AS PODND CONDITION LISTING Q
_ OF NIST TRAmint.n siaNDARDS USED. (A COPY _
_ g'gg,
Qi 9,
OP ixx CALingATION PRocunURE UTILTEED 3 a~
C
'-~ ~-' 90NTUus ROOTpenmT NUMBER SHOOLD v
AS,
_ APPEAR ON aux CALTanaTION <r-*TIFICATE AND 9,2, ON ArL ASSOCIATEu DOCUMEhPTS CALIBRATION 9,B, suca wvC/ TAG BEnULD BE ATTAt wwn/AFPIxxn Q1
_ M ins IN5iwDMiifr/EOUT PM1NT.
TwuCB STIcxx3 19,
_ OR TAG SHOULD INCLMDB ius ROUIPMENT NUMBER 11
_ DATE OF CALIBRATION. IDDGMTION OF THE 12 iaxSON PERDORMING CALTADAT10N lj,
_ iarr CALinn* TION.
. DUE DATE OF_
INsixGvm /EOUTDt-UrWi; li
_ WRFDW ADDROPRTETE a=fL BE SRAT.Wn N A, n
_ eNwEn AS m PRnv.vr DunnTnonTznD AnJUST-M
_ M1Ders.
Iivs rxGT rs /EGITIDbaDv r-SHOULD BE 1,7,
__ PANArTan FOR DELIVERY OR SRTDMENT IN A 18, MANNER TO PROTsC"r (9tr.IBRATION Th rasGRITY.
12, ANY ROUTPMRNT RRiuxNED WHICE COULD NOi BR 2Q
_ CALIBRAruu TO AN ACCurfABLE LEVEL SEAT 1 21 BR_
MARJtun IN A MANNER TO PREysNT TNADVnurENT 12
_ USE T.E. NOT CAT.TRDAi r.u.
21 MONCONPORMING.**
11 21 i
_o