Summary of 771108 Meeting W/Util & Legal Consultant to Review Status of Cps.Info Re 771103 Site Visit & Insp of Unit 3 Excavation Site Faults Provided.Lists of Key Milestone Dates & Meeting Attendees Encl
ML20210S508
Person / Time
Site: Palo Verde, Satsop
Issue date: 11/16/1977
From: Bournia A
Office of Nuclear Reactor Regulation
To:
Office of Nuclear Reactor Regulation
References
CON-WNP-1566 NUDOCS 8605290220
Download: ML20210S508 (7)


Text

_ _ - -

., _. -.. - ~.,.

---e.,.

  1. . 7';

..4

+

s y-3

~

9...N0y 161977

=

s c

e e

c S

Docket Nos. STN 50-508 1, ',

and STN 50-509

f.;x.f,S.c.

1

?.

1 s

?

. - ->,N.a 4,.

w

'.we -w:.s.pr 4,'::

y;3,,.~.,w m..

t. y,.

, ~.

e s.,-

a<

3

' hy,, ; yy,, n. x5. a,;, 3:2 J '4 f e f.

u

,:r.

j i

APPLICANT: jWashington Public Power Supply. System l(WPPSS)

~ ( i,.,,

' 3 s

a eg w ne - :. my %

y.

FACILITYQ WPPSS. Nuclear Projects No. 3 and No.'5 (WNP-3 and WNP-5) y J

s 7

3-

. p..

v.

,c SU8 JECT:

MEETING WITH WASHINGTON PUBLIC POWER SUPPLY SYSTEM TO g,

'. +.

r (-

" REVIEW STATUS OF WNP-3 AND WNP-3

>~,

r' ' : ' -

a.

4;,.

i

Background

i The applicant requested a meeting with the staff to discuss its need for construction pemits for WNP-3 and WNP-5. A meeting was held on November 8,1977 with the applicant and his legal consultant to address i

. this topic.. A list of, the meeting attendees is shown in Enclosure 1.

..,,,.;.... w. m. w-e w,-

.s

.w

.+ -

y sThe record for the WNP-3 and WNP-5 hearing is being kept open as a

- T' '

result of two items:

(1)the1872PacificNorthwestearthquake,and (2) the faulting uncovered at the WNP-3 excavation. We have made a

~

site visit to inspect the faulting offthe excavation in Unit No. 3 and reported in a trip report dated November 3,1977.

In addition j

on November 4, 1977, the ACRS concluded a meeting addressing the j

1872 Pacific Northwest earthquake as a generic issue.

..-.c.

Disscussion

~

The applicant reviewed the key construction milestone dates and the geology / seismology chronology. Enclosure 2 contains the vu-graphs presented. The applicant stated that in order for the Unit No. 3 e

p' commercial operation date of September 1983 be met, a construction pemit is required by December 1,1977. The applicant urged the staff l to proceed with the open items to the Board, since.axhaustive~

i

> ~

i iinformation is now available on the 1872 earthquake, in order fo~r a PY F

' decision may be made it issue the construction permits. Following a

.*yj j.

discussion, the applicant was. requested to provide the following:

(1) Submit to us, as soon as possible, the technical information requested in a telecon on November 3.1977 and confirmed in a l

l

, letter dated November 9,1977, on the faulting in Unit No. 3.

\\

Additionally, an affidavit should be transmitted to the Board 3

l with their findings.

1 t,

g k,

orric = *

. l l

l I.

J 8605290220 771116 PDR ADOCK 05000528 3 ;; -'n su=====>

A j *. '.-

PDR i

2 g

\\

    • T8 *

._ 7 Ferma ABC sts (Rev. 94H ABCM 0240 2.w, c s 1.u;.:,

n

.o ~ eN MR m / D u. s. eovanm=sur pan = Time opvicas sets.sae-see k

,..j.,,

- - '. ~..+ %>.4..e h*-.-

-+E w i**a h ~

(

.e

~ 'h NOV 161977 l

.-2

/

.(2) Prepare an affidavit to the Board addressing a full disclosure of the facts on the 1872 Pacific Northwest earthquake, including j

'the staff findings as reported in the SER and the supplements; an evaluation of the U. 5. Geological Survey position as presented

%,ev in a letter dated July 21,1977 on the Skagit docket and its

.fmJL 'l presentation before the ACRS; the ACRS evaluation which will be

-es reported in their letter;-and the results of the applicant's and its e-i.f., '-O ',consHtant's investigations.

4'.r.~"-

e

"~-

N o

wg

'The first item is contemplated to be completed approximately by November 18. 1977 and the second item, soon after the ACRS letter l,

N..is issued addressing the earthquake. Once the hbove items have been 12 submitted and reviewed by us,'we would submit our affidavit with our' 6..

P findings to the Board. '

Original Signed By:

[

T. Bournia I

Anthony Bournia, Project Manager i

Light Water Reactors Branch No. 3 I, -

s..

,-7,,,-

t..

c

,2 Z C. s[ l C C 1. Division of Project Management i

Enclosures:

~w y:,.

.x

~

~#

j As Stated l

cc w/ enclosures:

i Washington Public Power Supply System ATTN: Mr. N. O. Strand

,l, Managing Director P. O. Box 968 3000 George Washington Way Richland, Washington.99352

.x; 4

4;.

  • ' Joseph B. Knotts, Jr., Aq
~

z.

P

'DeBevotie-& L1bennen x

Shoreham Building Suite 700

'* 7 800 15th Street, N. W. '

" ~'.

~'

.a. Washington, D. C.

20005 x

~ x.c

w
c. c

, Richard Q. Ouigley, Esq.

~. Washington Public Power Supply System

- i 3000 George Washington Way Richland, Washington 99352 s

s o,

LWR #3 ABourTia: cec

_1.W g 0

OPaM-0 41

~ I/JS/77 ll/lS/77 l

oaru p Fesma ABC 318 (Rev. S53) ABCM 0240

$= u. s. oov.anunnv eninvene orrecas sev4.sas.c os

,.gg;

" 3U'" * ? e.. f,.L;e.u.%,.c#, ww - e u. u. m...

4<,

._ -u.J.; &

h A-a imm _L,__ --

p l

WMP-3 & WNP-5

~

KEY SCllEDULE DATES

]

EVENT WNP-3 WNP-5 L

j 2, /

  • l'~~s */ / /

l C0.1STRUCT10fl PERfilT ISSUED R/77 11/77 0!

It'ITIAL STRUCTURAL C0flCRETE 2/78 7/78 START PIPING INSTALLAT10t!

12/78 6/80,

START ELECTRICAL INSTALLATION 5/79 7/80 FILE Fit!AL SAFETY ANALYSIS REPORT 12/80 12/80 SET REACTOR VESSEL 1/31 3/82

u. i w

START PRE-0PERATIONAL TESTING 6/81 2/83 nPERATlilG LICEt!SE ISSUED; LOAD FUEL 3/83 9/84 C0tEERCIAL OPERATION 9/83 3/85

^

  • * * '.., Acin.y Cm e-

.t J. c, ( '

r./

~

3

. -}

ENCLOSURE 2' ATTENDANCE LIST WASHINGTON PUBLIC POWER SUPPLY S' STEM NUCLEAR PROJECTS NO. 3 AND NO. 5 NOVEMBER 8,1977 i

i NRC WPPSS i

E. Case D. Renberger R. DeYoung J. Knotts (legal consultant)

C. Stepp D. Tillson A. Bournia D. Swanson

  • J. Norris
  • Part-time e

l r

l

4 WNP-3 & ilNP-5 KEY DATES WNP-3 WNP-5 i

Vl!

o COMPLETE REACTOR BUILDING EXCAVATION 12/15/77 7/1/78 o

START PLACING REBAR 12/15/77 7/1/78

[

o FIRST CONCRETE - BASE MAT 2/1/78 8/78 l

o COMPLETE MAT AND START SHIELD BUILDING -

11/15/78 CONTINUOUS SLIP FORM o

COMPLETE SHIELD BUILDING (top ouT) 6/1/78 i

l V

l l

l l

..t l

0 I

GEOLOGY / SEISM 0 LOGY CHRONOLOGY i

j o PSAR 8/2/74 o

... FAULTS WITH NINOR OFF-i SETS ON THE ORDER OF SEVERAL I'

FEET, WHICH MIGHT BE FOUND l

IN THE EXCAVATION AT THE l

PLANT LOCATION AND AT THE SITE WOULD NOT BE CAPABLE."

o 1872 E.Q. - NOT CONTROLLING o SER 2/13/76 o NO FAULTS WHICH WOULD LOCALIZE EARTHQUAKES IN THE POWER BLOCK AREA.

o

.32g ACCEPTABLE o NRC LETTER TO ASLB 9/2/76 o WAITING ON INFO FROM USGS ON 1872 E.Q.

o NRC STAFF AFFIDAVIT 3/15/77 o OK TO PROCEED - 1872 E.Q.

~

o SER SUP. 3 4/22/77 o 1872 E.Q. - NO IMPACT ON i

.32g o NRC LETTER TO ASLB 8/17/77 o RE-ANALYZING 1872 E.Q.

o NRC SITE VISIT 10/26/77 o EXCAVATION FAULTS INSPECTED A:/t 5.

/ j:

7

~~

A c p s cv:l ca,...

,/.

e

~

,.)

G-i s

'1 6

STATUS AND ACTIONS NEEDED j

o 1872 EARTHQUAKE DOES NOT IMPACT WNP-3/5 i

o NEED AFFIDAVIT TO 3/5 ASLB FROM NRC STAFF (N0 FURTHER INPUTS REQUIRED BY WPPSS) o EXCAVATION OFFSETS CONSISTENT WITH 1974 DISCLOSURE (PSAR) o NEED AFFIDAVIT TO 3/5 ASLB FROM NRC STAFF (WPPSSINPUT

/4 E

/

c. /

)

o CONSTRUCTION PERMIT NEEDED 12/1/77 i

-w

-