1 N4.

i 3

'Af 2NRC-7-021 8eewer Valley No. 2 Unit Project organization

$.s'o$$'

Telecopy

) 1 Est.160 February 2, 1987 Shippingport, PA 15077 Mr. Harold R. Denton Office of Nuclear Reactor Regulation United States Nuclear Regulatory Commission Washington, DC 20555 ATTENTION:

Mr. Peter Tam, Project Manager Division of PWR Licensing - A Office of Nuclear Reactor Regulation

SUBJECT:

Beaver Valley Power Station - Unit No. 2 Docket No. 50-412 Request for Partial Exenption fra General Design Criterion 4 Based on the WHIPJET Program

REFERENCE:

1)

Letter 2NRC-6-112 from J. J. Carey (DLC) to H. R. Denton (NRC) dated October 23, 1986.

Gentlemen:

The purpose of this letter is to request a partial exenption fran General Design Criterion (GDC) 4 of Appendix A to 10CFR Part 50 by applying " leak-before-break" tecnnology as an alternative to providing hardware to protect against dynanic effects resulting fran certain postulated austantic steel pipe ruptures inside containnent.

The scope of the exenption being requested is limited to only certain high energy, balance-of-plant, piping systens.

They are identified in Attachment 1 to this letter.

The specific break locations and pipe whip restraints and jet impingement shields that are to be eliminated are also indentified in attachment 1.

The technical infonnation to justify this request for exenption is contained in the revised WHIPJET Progran Report.

Five (5) copies of this re-port are being transmitted at the sane time as this letter under seperate cover.

This report is a revision to the final report submitted by the referenced letter and the revisions are based on agreenents reached with the NRC staff and its consultants in the WHIPJET meeting of January 16, 1987 in Bethesoa, Maryland.

Please note that Appendix B of the WHIPJET Progran Report contains propri-etary infonnation on the properties of austentic steel base metal and weld metal.

Tne request for withholding this information from public oisclosure in accordance witn 10CFR2.790 is enclosed with the report.

This application for withholding is being made by Ouquesne Light Company on the behalf of its sub-contractor on this project, Robert L. Cloud and Associates (affidavit fnclosed with report),

M gJ 8702170628 870202 PDR ADOCK 05000412

'f gb Ng (30 M[

A PDH "GT E i

o

  1. jtJM" f

f,, O f

'p

n United States Nuclear Regulatory Commission Mr. Harold R. Denton, Director Request for Partial Exemption From General Design Criterion 4 Based on the WHIPJET Pro 6 ram f

Page 2

-p*.

~

- 1 Upon approval of this exemption request, the FSAR will be amended to reflect this alternative design basis.

The e,xpeditions issuance of a Safety Evaluation Report and a partial exemption to GDC 4 would be greatly appreciated.

DUQUESNE LIGHT COMPANY By v

gr. JfAarey Senior Vice President JJS/ijr NR/JJC/WHIPJET tachnent NAR 1Mr. P. Tam, Project Manager cc:

Mr. J. Beall, NRC Sr. Resident Inspector Ms. A. Asars, NRC Resident Inspector INP0 Records Center NRC Document Control Desk t

I I

i

4 m

United States Nuclear Regulatcry Conunission Mr. Harold R. Denton, Director Request for Partial Exenption Fron General Design Criterion 4 Based on the WHIPJET Program Page 3 COMMONWEALTH OF PENNSYLVANIA )

SS:

COUNTY OF BEAVER On this M day of db gaz/r,/k

, before me, a Notary Public in and for said Commonwealth [nd County, personally appeared J. J. Carey, who being duly sworn, deposed and said that (1) he is Senior Vice. President of Duquesne Light, (2) he is duly authorized to execute and file the foregoing Submittal on behalf of said Company, and (3) the statenents set forth in the Submittal are true and correct to the best of his knowledge.

M Notary Public 3HOLA ti. 7 ATTMi, W11 ART Putus SWlPPHCP0tf 904), BEAVER CMHRT ET COBElssl0E EXPitES OCT. 23,1989 piaber.Pesesytamia Asseelstles of M E

~

~~

ATTACHMENT 1 WHIPJET PROGRAM PIPE DREAKS AND HARDWARE LINE NUMBER

' ; BREAK NUMBER TYPE WELD HARDWARE (6-inch SIS tolCold Leg A) 2 SIS-006-012-1 2 SIS-091-C-C TE FW 2 SIS-PRR-850 2 SIS-151-C-C EA FW 2 SIS-PRR-850 2 SIS-152-C-L EA FW 2 SIS-JIS-850 2 SIS-153-C-C EA FW 2 SIS-PRR-851 2 SIS-154-C-L EA FW 2 SIS-JIS-851 2 SIS-155-C-C EA FW 2 SIS-PRR-851 2 SIS-156-C-L EA FW 2 SIS-JIS-851 2 SIS-158-C-L EA FW 2 SIS-JIS-851 l

2 SIS-181-C-L EA FW 2 SIS-JIS-851 2 SIS-006-269-1 NO ASSOCIATED HARDWARE (6-inch SIS to Cold Leg B) 2 SIS-006-015-1 2 SIS-162-C-L TE FW 2 SIS-JIS-860 2 SIS-164-C-L EA FW 2 SIS-JIS-860 2 SIS-166-C-L EA FW 2 SIS-JIS-860 2 SIS-168-C-L EA FW 2 SIS-JIS-860 2 SIS-183-C-L EA FW 2 SIS-JIS-860 2 SIS-006-270-1 NO ASSOCIATED HARDWARE (6-inch SIS to Cold Leg C) 2 SIS-006-016-1 2 SIS-177-C-C TE FW 2 SIS-PRR-871,JIS-871 2 SIS-179-C-C EA FW 2 SIS-PRR-872 2 SIS-006-271-1 NO ASSOCIATED HARDWARE (6-inch SIS to Hot Leg A) 2 SIS-006-026-1 NO ASSOCIATED HARDWARE 2 SIS-006-268-1 NO ASSOCIATED HARDWARE i

(6-inch SIS to Hot Leg B) 2 SIS-006-024-1 2 SIS-118-C-C TE FW 2 SIS-PRR-860 2 SIS-119-C-C EA FW 2 SIS-PRR-861 2 SIS-006-266-1 NO ASSOCIATED HARDWARE (6-inch SIS to Hot Leg C) 2 2 SIS-006-025-1 2 SIS-147-C-C TE FW 2 SIS-PRR-870 2 SIS-148-C-L EA FW 2 SIS-JIS-870 2 SIS-006-267-1 NO ASSOCIATED HARDWARE t

(8-inch Loop A Bypass) 2RCS-008-020-1 2RCS-004-C-C TE FW 2RCS-PRR-818 2RCS-008-021-1 2RCS-001-C-C TE FW 2RCS-PRR-853 l

l i

1 (ctntinu;d)

LINE NUMBER BREAK NUMBER TYPE WELD HARDWARE

. +& -

-(8-inch Loop 3>aypass) 2RCS-008-040-1~ / 2RCS-008-C-C TE FW 2RCS-PRR-820

-2RCS-008-041-1.Y.2RCS-005-C-C TE FW 2RCS-PRR-852

.a (8-inch Loop C Bypass) 2RCS-008-060-1 2RCS-012-C-C TE FW 2RCS-PRR-828 2RCS-008-061-1 2RCS-009-C-C TE FW 2RCS-PRR-851 (10-inch RHS Discharge, Cubicle B) 2RHS-010-023-1 NO ASSOCIATED HARDWARE (10-inch RHS Discharge,' Cubicle C) 2RHS-010-024-1 2RES-002-C-C TE FW 2 SIS-PRR-825 (12-inch RHS Suction from Hot Leg A) 2RHS-012-001-1 2RHS-003-C-C TE FW 2RHS-PRR-801 2RHS-012-056-1 NO ASSOCIATED HARDWARE (12-inch SIS to Cold Leg A) 2 SIS-012-289-1 2 SIS-003-C-L EA BM 2 SIS-PRR-806 2 SIS-005-C-L EA BM 2 SIS-PRR-806 2 SIS-007-C-L EA BM 2 SIS-PRR-806 2 SIS-009-C-L EA SW 2 SIS-PRR-806 2 SIS-010-C-C EA SW 2 SIS-PRR-806 2 SIS-013-C-L EA FW 2 SIS-PRR-806 2 SIS-Oll-C-L EA SW 2 SIS-PRR-806 2 SIS-012-C-C EA FW 2 SIS-PRR-806,804 2 SIS-012-067-1 NO ASSOCIATED HARDWARE 2 SIS-012-066-2 NO ASSOCIATED HARDWARE

-2 SIS-012-250-2 NO ASSOCIATED HARDWARE (12-inch SIS to Cold't.eg B) 2 SIS-012-288-1 y-2 SIS-016-C-C TE FW 2 SIS-JIS-803 T 'f2 SIS-017-C-C EA SW 2 SIS-JIS-803 C.28IS-018-C-L EA SW 2 SIS-JIS-805 2 SIS-020-C-L EA SW 2 SIS-JIS-805 2 SIS-022-C-L EA SW 2 SIS-JIS-805 2 SIS-024-C-L EA SW 2 SIS-PRR-815,818 2 SIS-026-C-L EA BM 2 SIS-PRR-817 2 SIS-028-C-L EA BM 2 SIS-PRR-816 2 SIS-012-071-1 NO ASSOCIATED HARDWARE 2 SIS-012-070-2

~

NO ASSOCIATED HARDWARE 2 SIS-012-252-2 NO ASSOCIATED HARDWARE (continued)

LINE NUMBER BREAK NUMBER TYPE WELD BARDWARE (12-inch SIS totCold Leg C) 2 SIS-012-287-1:2E 2 SIS-032-C-L EA SW 2 SIS-JIS-800

" ~ "

". 2 SIS-034-C-L EA SW 2 SIS-JIS-800 2 SIS-035-C-C EA SW 2 SIS-PRR-824 2 SIS-036-C-L EA SW 2 SIS-JIS-800 2 SIS-037-C-C EA FW 2 SIS-PRR-827 2 SIS-038-C-L EA FW 2 SIS-PRR-827 2 SIS-039-C-C EA BM 2 SIS-PRR-824 2 SIS-040-C-L EA BM 2 SIS-PRR-824 2 SIS-041-C-C EA SW 2 SIS-PRR-826 2 SIS-042-C-L EA SW 2 SIS-PRR-827 2 SIS-043-C-C EA SW 2 SIS-PER-825 2 SIS-044-C-L EA SW 2 SIS-PRR-827 2 SIS-012-069-1 NO ASSOCIATED BARDWARE 2 SIS-012-068-2 NO ASSOCIATED BARDWARE 2 SIS-012-251-2 NO ASSOCIATED BARDWARE (14-inch Surge Line to Bot Leg C) 2RCS-014-084-1 2RCS-241-C-C TE FW 2RCS-PRR-814,815 2RCS-242-C-C EA SW 2RCS-PRR-814 2RCS-243-C-L BA SW 2RCS-PRR-816 2RCS-244-C-C EA SW 2RCS-PRR-825 2RCS-245-C-L EA SW 2RCS-PRR-816 2RCS-246-C-C EA BM 2RCS-PRR-814,815 2RCS-247-C-L EA BM 2RCS-PRR-815,816 2RCS-248-C-C EA BM 2RCS-PRR-825,814 2RCS-249-C-L EA BM 2RCS-PRR-816 2RCS-250-C-C EA BM 2RCS-PRR-825,815 2RCS-252-C-C EA BM 2RCS-PRR-815,814,826 2RCS-254-C-C EA FW 2RCS-PRR-815,825,810 2RCS-256-C-C TE FW 2RCS-PRR-807,824 I

CODE:

TE = Terminal End Break EA = Exceeds the Stress and/or Fatigue Factor Threshold for Break r

FW = A Field Fabricated Weld is Made at This Postulated Pipe Rupture Location SW = A Shop Fabricated Weld is Made.at This Postulated Pipe l

Rupture Location BM = Base Metal.

There is no weld at This Postulated Pipe Rupture Location i


m*

,-,----~-m

,---r---~,-----v,,-


e