Text
/m
/
) CoRNINNueelth Eclison
[._
One First Nabonel Plaza. Chcago. tilinois
\\s' Address Reply to: Post Omco Box 767 1E O l Chcago, Illinois 60600 0767 0.
January 15, 1987 PRIORITY ROUTIfiG
- pgi 7%
Mr. James G. Keppler b
Regional Administrator
[
U.S. Nuclear Regulatory Commission L
i
'~
Region III FIL 799 Roosevelt Road Glen Ellyn, IL 60137
Subject:
Byron Station Unit 1 Snubber Functional Testing NRC Docket No. 50-454
Dear Mr. Keppler:
In accordance with Technical Specification 4.7.8e, this is to inform you of the sample plan selected for functional testing of snubbers during the Unit I refueling outage scheduled to begin February, 1987. Byron will utilize sample plan 4.7.8e.1 (10% of the total of that type) for the hydraulic steam generator snubbers and sample plan 4.7.8e.3 (55 snubbers /
initial sample) for the remaining mechanical snubbers.
Please direct any questions regarding this matter to this office.
Very truly yours, K. A. Ainger Nuclear Licensing Administrator 1m cc: Byron Resident Inspector jg 2 01987 0702170602 870115 DR ADOOK 05000454 PCR 2600K i
_, _. _., _ _ _.. _~
.. _ _ _ _ _ _. _, _ _ _ _ _ _.. _ _ _ _. _ _ _ _ _ _ _ _ _ _ _. _ _ _ _ _. _ _ _. _ - -.., _. _ _ _ _ - _ _ _ _ _ _