p..

l 94%

Y) CD g

UNITED STATES g

j NUCLEAR REGULATO,RY COMMISSION n

l' WAShlNGToN, D.C. 2066H001 i

o

          • g WL 2 3 1999

~

NVT Technologies, Inc.

+ RECElm JUL 2 7 M l

ATTN: V. Thanh Nguyen, President 21515 Ridgetop Circle, Suite 300 Sterling, VA 20166

SUBJECT:

CONTRACT NO. NRC-10-99-141

Dear Mr. Nguyen:

We have reviewed your deficiency list dated June 30,1999, and our analysis of your recommendations follows:

1.

Agree.

2.

Agree. NRC will correct the problem.

3.

Agree. NRC will correct the problem.

4.

Agree. NRC will correct the problem.

5.

Agree. This problem has been corrected.

6.

Agree. NRC will correct the problem.

7.

Agree. The problem has been corrected 8.

Agree. NRC will correct the problem.

9.

Agree. NRC will correct the problem.

10.

Agree.

11.

Agree. NRC is currently in the process of correcting the problem.

12.

Agree. The problem has been corrected.

13.

Agree. NRC is currently in the process correcting the problem.

14.

Agree. The problem has been corrected.

15.

Agree. NRC will correct the problem.

16.

Agree. NRC will correct the problem.

17.

Agree. NRC will correct the problem.

18.

A determination cannot be made until the fire alarm is activated.

19.

Agree.

20.

Agree. This problem has been corrected.

21.

Agree. This problem has been corrected.

22.

Disagree. This area no longer is leaking.

23.

A determination cannot be made until a heavy rain.

24.

Agree.

25.

Agree.

26.

Agree. The problem has been corrected.

27.

Agree.

28.

Agree. The problem has been corrected.

29.

Agree. NRC will correct the problem.

! ) h' n'[ i ~g' 30.

Agree.

w 31.

Agree.

32.

Agree.

33.

Agree. NRC will correct the problem.

9908170192 990811

[9[.141 P

PDR

4,.

]

o 34, Agree.

RECENO N 35.

A determination cannot be made until a rain storm occurs.

I 36.

A determination cannot be made until a rain storm occurs.

37.

A determination cannot be made until a rain storm occurs.

38.

Agree. NRC will correct the problem.

39.

A determination cannot be made until a rain storm occurs.

40.

Agree.

41.

Agree.

42.

Agree.

43.

Agree.

44.

Agree.

45.

Agree.

46.

Agree.

47.

Agree.

48.

Agree. Reirnbursable Work Order Issued to NVT to correct problem.

49.

Agree. NRC will correct problem.

No action should be taken on those areas which we have agreed is a deficiency until the NRC Project Officer or designee issues a reimbursable work order.

You are hereby requested to provide your acceptance of the above analysis by signing below and returning to Deborah Neff, Contract Specialist, not later than 5 working days from the date of this letter.

Should you have any questions regarding this letter, please contact Ms. Neff, Contract Specialist, on (301) 415-8160.

Sincerely, i

Mary

,Mr, Contracting Officer Contract nagement Branch No.1 l

Division of Contracts & Property Management Office of Administration i

cc: R. Nader, NVT

(

cceptance ( ) Non-Acceptance

- bm Name g/ela Datef I

i J