ML20210R430

From kanterella
Jump to navigation Jump to search
Forwards Insp Repts 50-498/97-18 & 50-499/97-18 on 970721-24 & NOV Re Failure to Revise Spec 4R129NS1014, Replacement SG, Rev 0,to Reflect Approved Vendor Use of SA-533,grade B, Class 2 Plate Matls
ML20210R430
Person / Time
Site: South Texas  
Issue date: 08/27/1997
From: Howell A
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Cottle W
HOUSTON LIGHTING & POWER CO.
Shared Package
ML20210R435 List:
References
50-498-97-18, 50-499-97-18, NUDOCS 9709030119
Download: ML20210R430 (6)


See also: IR 05000498/1997018

Text

'

o

!

!

l

,

[\\p" '" %,[\\

uNtf ro stof f S

-NUCLEAR REGULATORY COMMISSION

,,

A

[

$

RioloN lv

.

'

611 RV AN PL AFA DRIVf, sulTE 400

%,

./

AR L INGToN, it N AS 76011 8064

'

....*

August 27,1907

-

. William T. Cottle, Group Vice

President, Nuclear

l

- Houston Lighting & Power Company

P.O. Box 289

Wadsworth, Texas 77483

,

SUBJECT: NRC INSPECTION REPORT 50 498/97 18;50 499/97 18 AND NOTICE La

i

VIOLATION

1

,

Dear Mr. Cottle:

An NRC inspection of steam generator replacement activities was conducted July 2124,

!

1997, at your South Texas Propet Electric Generating Station, Units 1 and 2 reactor

I

f acilities, with an exit meeting co iducted on July 24,1997, at the conclusion of the onsite

inspection. The enclosed report piesents the scope and results of that inspection.

'

Overall, the results of the inspection indicate that you have developed both comprehensive

technical and quality requirements for yo';r replacement steam generators and implemented

proactive measures to assure appropriate quality standards are maintained by

l

Westinghouse and its subvendors during materials manufacture and steam generator vessel

l

fabrication. One violation was identified, however, pertaining to the failure to revise.

'

-

Specification 4R129NS1014, " Replacement Steam Generators," Revision 0, to reflect the

,

approved vendor use of GA 533, Grade B, Class

plate materials for the steam generator

upper shells. Specifically, the specification permitted the use of only SA 533, Grade B,

Class 1 plate material (a material with lower yleid and ultimate tensile strength properties

,

than the Class 2 grade). This issue is of concern since we believe that it indicates, in

.at least ono instar.ce, that approvals of vendor drawing and document submittats have

i

been conducted without appropriate raference to and consideration of your governing

"

steam generamr specification requirements.

The violation

.ted in the enclosed Notice of Violation (Notice) and the circumstances

surrounding ti.

violation are described in detallin the enclosed report. Please note that

i

. you are required to respond to this letter and should follow the instructions specified in the

!

enclosed Notice when preparing your response. The NRC will use your response, in part,

to determine whether further enforcement action is necessary to ensure compliance with

'

regulatory requirements.

,

1

)

,

'

'

9709030t19 970827

PDR

ADOCK 05000498

g

PDR

-

.

_ _ . . , . . _ _ _ , _ _ - _ ,

.

-

. . .

.

_ , . _ . . .

y-

_ _ _ .-. _ __ _ _ ___-_____ - _ -.

. .__

9:

.-

'-

Houston Lichti_ng & Power Company-

-4 2-

--

l

l

During the inspection, we additionally noted that' the.+mperage value recorded on Ansaldo

_

-

l nondestructive examination records (for prod magnetic particle examinations of the steam-

generator upper shell wold joint preparations and the b? ?k ground root of the initial upper

l

shelllongitudinal _ welds) appeared to be contrary to the maximum value permitted by the

applicable Article 7, paragraph T-743.2 of the ASME Section V Code, it is regt asted that

~

the corrective actions taken by Westinghouse to resolve this potential ASME Code

' violation be furnished with your response to_ the enclosed Notice.

in accordance with'10 CFR ?.790 of the NRC's " Rules of Practice," a copy of this letter,

-its enclosure, and your response will te placed in the NRC Public Document Room (PDR).

To the extent possible,-your response should no'r include any personal privacy, proprietary,

or safeguards information so that it can be placed in the PDR without redaction.

Should you have any questions concerning this inspectioti, we will be pleased to discuss

them._with you.

Sincerely,

" -).

-

.

V/

h Arth

T. Howsil lil,-Director--

U

Division of Reactor Safety;

.-

Docket _Nos.: 50-498;50-499

, License Nos.: NPF-76; NPF-80

- Enclosures:

1.' Notice of Violation -

2. _ NRC Inspection Report

50-498/97-18;50-499/97-18

cc w/ enclosures:

Lawrence E. Martin, General Manager-

Nuclear. Assurance & Licensing _

' Houston Lighting & Power Company

P.O. Box 289

- Wadsworth, Texas ? 77493 '

Mr.1C. Lanier/Mr. M.' B. Lee

- City cl Austin

~

Electric Utility Department

-721.Barton Springs Road

- Austin, Texas ~ 78704-

.

-

.

., ,

.. . . .

,

. I-

. , ,.

..

. . . , . , -

-

\\

.

.

.

_ _

_ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

-.

.

Houston Lighting & Power Company

3

Mr. K. J. Fiedler/Mr. M. T. Hardt

City Public Service Board

j

P.O. Box 1771

j

l

San Antonio, Texas 78296

]

Jack R. Newman, Esq.

Morgan, Lewis & Bockius

1800 M. Street, N.W.

Washington, D.C. 20036 5869

I

Mr. G. E. Vaughn/Mr. C. A, Johnson

i

Central Power & Light Co.npany

P.O. Box 289

Mail Code: N5012

Wadsworth, Texas 77483

INPO

Records Center

700 Galleria Parkway

Atlanta, Georgia 30339-5957

Dr. Bertram Wolfe

15453 Via Vaquero

Monte Sereno, California 95030

Bureau of Radiation Control

State of Texas

1100 West 49th Street

Austin, Texas 78756

Mr. Glenn W. Dishong

Texas Public Utility Commission

7800 Shoal Creek Blvd.

Suite 400N

Austin, Texas 78757-1024

Andy Barrett, Director

Environmental Policy

Office of the Governor

P.O. Box 12428

' Austin, Texas 78711

. ______

f:.

,

,

!

Houston Ughting & Power Company

-4-

Judge, Matagorda County

. Matagorda County Courthouse

1700 Seventh Street

Bay City, Texas 77414

l

Licensing Representative

Houston Lighting & Power Company

l

'

l

Suite 610

l

l

__Bethesda, Maryland -20814

Three Metro Center

{

!-

1

Rufus S. Scott, Associate

General Counsel

Houston Lighting & Power Company

P.O. Box 61867 -

Houston, Texas 77208

,

Joseph R. Egan, Esq.-

Egan & Associates, P.C,

- 2300 N Street, N.W.

Washington, D.C. 20037

_.

_

. - - - _ _ _ - _ _ - - - _

..

. .

..

..

i

.+.

, .. ..

[

-4- - --Houston Lighting & Power Company--

5-

E Mail report to T. Frye (TJF)

1

E mail report to T. Hiltz (TGH)

L E Mail report to NRR Event Tracking System (IPAS).

E-Mail report to Document Control Desk (DOCDESK)

bec' to DCD (IE01) .

' bec distrib by RIV:

Regional Administrator-

Resident inspector

.- DRP Director -

- DRS PSB

Branch Chief (DRP/A).

MIS System .

Project Engineer (DRP/A)

RIV File-

. Branch Chief (DRP/TSS)

R.- Bachmann, OGC (MS: 15-B 18)

-!

l

!

1

Y

.y.

DOCUMENT _NAME: R:\\_STP\\ST718RP.lXB

- To receive copy of document, Indicate in box: "C" * Copy without enclosures

"E" = Copy with enclosures "N" = No copy -

RIV:TA-

D:DRP -

D:DRQ

,

,

_

IBarnes/imb ~'~ #- :5- TPGwynn RATH69 ett 111 fo

'

08/4/97

08t#97 U

08M/97:

OFFICIAL RECORD COPY

._

_

____-___________-_ _

-

)

7

Houston Lighting & Power Company

5-

E-Mail report to T. Frye (TJF)

E-mail report to T. Hiltz (TGH)

'

E-Mail report to NRR Event Tracking System (IPAS)

E-Mail report to Document Control Desk (DOCDESK)

bec to DCD (IE01)

bec distrib, by RIV:

l

Regional Administrator

Resident inspector

l

l

DRP Director

DRS PSB

l

Branch Chief (DRP/A)

MIS System

l

Project Engineer (DRP/A)

RIV File

Branch Chief (DRP/TSS)

R. Bachmann, OGC (MS: 15 B 18)

DOCUMENT NAME: R:\\_STP\\ST718RP.lXB

To receive copy of document. Indicate in box: "C" = Copy without enclosures "E" = Copy with enclosures "N" = No copy

RIV:TA

D:DRP

D:DRQp

,

_,

,

IBarnes/imb W-S

TPGwynn RATH6Meti til ?

08/d/97

08th97 U

08M/97

OFFICIAL RECORD COPY

Y

, _ .

.-

_ _ _