ML20210R259

From kanterella
Jump to navigation Jump to search
Forwards Planned Snubber Functional Testing for Upcoming Outages for Q1P01 & Q2P01
ML20210R259
Person / Time
Site: Quad Cities  
Issue date: 08/21/1997
From: Kraft E
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
ESK-97-175, NUDOCS 9709020363
Download: ML20210R259 (3)


Text

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

o,nnnonuann i.n-n o nne.un Qu nl( ~ Hits (.t noating Natu>n

, 22? llt.hw.th Au nut htth I onlai.i. H 6114J 9"in h1 MNM s l2 4l ESK 97175 August 21,1997 U. S. Nuclear Regulatory Commission Washington, D. C 20555 Attention:

Document Control Desk

Subject:

Quad Cities Station Units 1 Technical Specification Snubber Function Testing for QlP01 and Q2P01 NRC Docket Numbers 50 254 and 50 265 In accordance with Technical Specification 4.1.5, enclosed is Quad Cities Station planned Snubber Functional Testing for the upcoming outages (Q1P01 and Q2P01).

If there are any questions or comments concerning this letter, please refer them to hir. Charles Peterson, Regulatory AKairs Manager, at (309) 654-2241, extension 3609.

Resp, trul c, f ([bf L bk' IM S. Krafl, Jr, Site Vice President Quad Cities Station Attachments: A, "QlP01 Technical Specification Snubber Functional Testing" B, "Q2P01 Technical Specification Snubber Functional Testing" cc:

A. B. Beach, NRC Regional Administrator, Rlli R. M. Pulsifer, NRC Project Manager, NRR

)

C. G. Miller, Senior Resident Inspector, Quad Cities g)

}

D. C Tubbs, MldAmerican Energy Company p\\

W. D. Leech, MidAmerican Energy Company F. A. Spangenberg, Regulatory AfTairs Manager, Dresden M. E. Wagner, Comed Licensing DCD - License (Both electronic and hard copy)

ESK Letter file.

9709020363 970821

~

PDR ADOCK 05000254 P

PDR OC0046 llllliBlill3!E,El,l!!!Il m _.,_

~

ATI'ACilMENT A

^

QUAD CITIES STATION UNIT 1 PLANNED SURVEILLANCE OUTAGE Q1 Pol ESK 97-175 PAGE 1 OF 1 d

TECllNICAL SPECIFICATION SNUlillER FUNCTIONAL TESTING SCOPE QUAD CITIES UNIT I TECil SPEC (SAFETY RELATED) ShUlillER POPULATION IS IIN SNUllllERS LFUNCTION Al, TESTING SCOPE l.

TECil SPEC 10% SAMPLE i

1 a.

Testing will be performed with the following procedures:

QCAP O410-05 e

e QCTS 0750-05 b.

Total of 12 snubbers will be tested during the outage, lireakdown of the sample is:

6 snubbers in the Drywell e

4 snubbers in the Reactor Huilding e 2 snubbers in the MSIV Room c.

System bleakdown of the 10% sample:

Tech Spee Snubbers!

TI:Cil SYSTLht

'NWR#

SERIAL.

SNUllill'R ISI NUMilfR IXX'ATION DRAWING SPEC #

TYPI: AND NUMllER SIZIL lt*

ItKKJ 970074354 01 3J07 PhA 10 jul2A % 102 DRY W 1.1.L. t h i 1.1.VLt.

M 994tF367 17*

1000 970074$83 01 3208 PsA 10 101211 % 102 DRY %I L L. thl t.lNil, M.994t>318 1 12 0202 970074433 01 1060 PsA 35 0200 W.127 DRYW 1 l.i. II Ahl.MI.N i M Wolb26'?

1 26 3tKK) 970074380-01 61290/46 1.11 $1 G4 6 NON col)l DRY % I l l. 2ND i lNI.L M 329A Mll. 6 1 31 0300 970074387 01 19804 Ps A l NONCODL DRY %1.Li. J "I LINIl-M 10$31L MIT. l.2.3.4 1 34 1000 97007438$ 01 12692 PS A 10 NON4 DDli kl AClok lil lKA. 2ND i l k M 9941) 122 l 3$

l'KK) 970074386 01 12732 PS A.10 NON4'ODl.

REAC' LOR llLDG,2ND l l.R M-994D 123 l.30 3(KK) 970074$8101 ti880 P$A.3$

NONCODL MMV ROOM M-988t h$

l.$2*

3tKK) 970074$74 01_

6879 PSA 3$

NON CODI.

MMV ROOM M 988D-4 1 74*

MKK) 970074388 01 61278-89 L.llAI GA.$ -

300ll41101.1 DkY% 1 Lt,2ND l.LVIL M 328 sill.7 l.93 10(K) 970074$77 01 1458 Ph A.100 NON-Col)L kl ACIOR ill ! Rill A5L Ml Ni M 1602 27 1 102*

1000 970074379-01 12763 PS A.10 80l$ll-M 202 kl.AclOR ill.D0 llASI At EN !

M 1606-24

' ASME CODE SECTION XI SNUllllERS Gary E. Knapp Interim Snubber Coordinator Station Support Engineering Group x2153 Pager # 226

ATTACllMENT H QUAD CITIES STATION UNIT 2 PLANNED SURVEILLANCE OUTAGE Q2P01 ESK 97-175 PAGE 1 OF 1

)

TECilNICAL SPECIFICATION SNUHHER FUNCTIONAL TESTING SCOPE QUAD CITIES UNIT 2 'l ECil SPEC (SAFETY RELATED) SNUHHER PO"ULATION IS 129 SNUHHERS A. FILN(TIONAL TESTING SC_ OPE 1.

TECil SPEC 10% SAMPLE:

Testing will be performed with the following Station procedures:

a.

QCAP O410-05 QCTS 0750-05 b.

Total of 13 snubbers will be tested during the outage.

i Breakdown of the sample is:

6 Snubbers in the Dryoell e

6 Snubbers in the Reactor Building 4

i Snubber in the Steam Tunnel e

c.

System breakdown of the 10% sample:

Tech Spee Scubbers:

1 TEGI SYSTE*a WORK SERIAL -

SNUHBER ISI NUMBER LOCATION DRAWING SPEC #

REQUEST #

TYPE AND HUMBER size J-3

  • I400 970088115-01 6773 PNA-10 1404-% 103Aall DRYW LLI 3RD t.I VEL M-lolotAYL 2 2$*

0202 9700h8 3 '4-01 1074 PF A-33 0200 % 132 DRY % LLI.,4%I LE VEL M-lo22LA279 2-28' 300t.*

979088.1734 6 61314 36 Lil St GA-n 300lA M-tu2.1 DRY %lLL 2ND LEVil.

M-329h hlll a 200 0300 970u883 72 01 4316 PSA !

NON-CO st DRY % t LL, lSI LEVLt M-1033-DO blif l &

4 2 48 3000 970088 0 4 04 7899 PSAd3 NON{0DL TURal BLOO. STLAM lONNll M-1020lA2 MIL I 2 59 3000 9700883 M ll 61301 44 LILSEGA 4 NON{ ODE DRYWI LL 2ND LA VEL M428L Mit 9 24 t

  • 3000 970084 % 9 04 6130G63 Lil5L GA-3 300 l H-M-101.1 DRY 4 ELt. 2ND l LVEL M 328f Sill 1 2 92 1000 97008h 6846 1403 P5A 100 NON-CODE RE ACIOR BLl0 llASEMLN1 M-1802 02 Sill. 2 2 98 1000 970088366 01 140$

PSA 100 NON4' ODE RLACIOR llLIM li ASLMENI M 1802-24 Mit 2 2 109 1400 97t048365 01 10197 PSA-3 NON-CODL REACIOR HL10 BA$LMI.NI M-8807 lo 2-l(7 4300 97uu88364-ol 12684 4%A 10 NON-CODL RE ACIOR DLOG DASLMLN'T M-181443 Sill. l a 2-136 luvu I 70088163-01 2680 PsA-l NON{UDL REACIOk itL10 LOP OI LORUS M-1814 2 142' 0300 970083362 01 24600 PSAd 0320 M 2VI REAM 11LDO thI FLOOK M-1018D-l123 Mll.

f I&2

  • ASME Code (Section XI) Snul,bers Gary E. Knapp Interim Snubbe Coordinator Station Supf :,i ngineering Group x2153 Pager# 226 j

~

~