Forwards SE Accepting First ten-yr Interval Inservice Insp Program Plan Requests for Relief 97-001 & 96-003,parts a & B
ML20210Q084
Person / Time
Site: Mcguire
Issue date: 08/22/1997
From: Berkow H
NRC (Affiliation Not Assigned)
To: Barron H
DUKE POWER CO.
Shared Package
ML20210Q089 List:
References
TAC-M95733, NUDOCS 9708280093
Download: ML20210Q084 (4)


Text

-.. _._..~

s.

r,0-370' a me:oq k

UNITED STATES p

g-y_

NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. See86 eeln August 22, 1997 t

1.

Mr. H. B. Barron L

Vice President, McGuire Site -

Duke Power Company

12700 Hagers Ferry Road Huntersville, North Carolina 28078-8985 i

SUBJECT:

EVALUATION OF THE FIRST 10-YEAR INTERVAL INSPECTION PROGRAM PLAN REQUESTS FOR RELIEF - MCGUIRE NUCLEAR STATION,

[

UNIT NO.-2 (TAC NO. M95733)

Dear Mr. Barron:

The staff, with technical' assistance from its contractor, the Idaho National Engineering and Environmental Laboratory (INEEL), has completed its review and evaluation of the Information provided by Duke Power Company, in its letter dated June 6,1996, related to the L

first 10 year interval inservice inspection program plan requests for relief for McGuire Nuclear

' Station, Unit 2. Additional information was provided by Duke Power Company in its letter dated April 29,1997. The staffs evaluation and conclusions are contained in Enclosure 1.

. is INEEL's Technical Letter Report.

The staff has reviewoo m licensee's submittal and concludes that the licensee has 4

maximized examination coverage for the reactor vessel welds and that service-induced degradation, if present, would have been detected. Thus, the licensee's proposed attemative contained in Request for Relief 97-001, provides an acceptable level of quality and safety.

e l

Therefore, the licensee's proposed attemative is authorized pursuant to l

10 CFR 50.55a(g)(6)(ii)(A) and 50.55a(s)(3)(ii).

. For Request for RelW No.96-003, Parts A and B, the staff concludes that the licensee has

- demonstrated that the Code coverage requirements are impractical for the subject weld:: at McGuire, Unit 2. Furthermore, by the examinations that were performed, the licensee's proposed altomative provides reasonable assurance of the st uctural e.tegrity of the subject l

components. Therefore, relief is granted pursuant to 10 CFR 50.55a(g)(6)(i) for Request for Relief No.96-003, Parts A and B.

6 4

1 9708280093-970822

~

hh kktY hhhU *3 hhh J

PDR ADOCK 05000370

~~

P=

PDR a

i l l llll,IllJ l ll

-. =

H. B. Barron August 22, 1997 This submittal completes the technical review performed by the staff under TAC No. M95733.

If you have any questions regarding this relief, please contact the Project Manager, Victor Nerses, at (301) 415-1484, Sincerely, ORIGINAL SIGNED BY L. WHEELER FOR:

Herbert I,. 3erkow, Director Project Directorate 11-2 Division of Reactor Projects - 1/11 Office of Nuclear Reactor Regulation Docket No. 50 370

Enclosures:

As stated (2) cc w/encis: See next page DISTRIBUTION Docket File ACRS PUBLIC NDudley, EDO PD ll-2 Rdg.

JJohnson, Ril BBoger SShaeffer, Ril HBerkow TMcLellan LBerry VNerses THarris (e-mail to TLH3) SE only GHill(2)

~ ) A~ O l OGC

/

  • See previous concurrence PDilh OFFICE PDil-2/PM*

PDil-2/LA*

OGC*

NAME VNERSES:cn L. BERRY MYOUNG

/ft!MIOW b f/M/97 DATE 7/23/97 7/23/97 8/14/97 fYEk NO COPY YES NO YES NO YES NO JOCUMENT NAME: G:\\MCGUIRE\\95733.RR OFFICIAL REGORD COPY

. :\\ n

s. v 0 J 'D

H.B.Banon,

This submittal completes the technical revie.y performed by the staff under TAC No. M95733.

If you have any questions regarding this relief, please contact the Project Manager, Victor Norses, at (301) 4151484.

f Sincerely, 40 rt N. Berkow, Director

/

Project Directorate ll 2 Division of Reactor Projects - l/ll Office of Nuclear Reactor Regulation Docket No. 50 370

Enclosures:

As stated (2) cc w/encis: See next page

McGuire Nuclear Station cc:

Mr. Paul R. Newton Ms. Karen E, Long Legal Department (PBOSE)

Assistant Attomey General Duke Power Company North Carolina Department of 422 South Church Street Justice Charlotte, North Carolina 28242 P. O. Box 629 Raleigh, North Carolina 27602 County Manager of Mecklenburg County Mr. G. A. Copp 720 East Fourth Street Licensing - EC050 Charlotte, North Carolina 28202 Duke Power Company 526 South Churc*. Street Michael T. Cash Charlotte, North Carolina 28242 Regulatory Compliance Manager Duke Power Company Regional Administrator, Region 11 McGuire Nuclear Site U.S. Nuclear Regulatory Commission 12700 Hagers Ferry Road Atlanta Fedcral Center Huntersville, North Carolina 28078 61 Forsyth Street, S.W., Suite 23T85 Atlanta, Georgia 30303 J. Michael McGarry, Ill, Esquire Winston and Strawn Elaine Wathen, Lead REP Planner 1400 L Street, NW, Division of Emergency Management Washington, DC 20005 116 West Jones Street Raleigh, North Carolina 27603-1335 Senior Resident inspector c/o U. S. Nuclear Regulatory Mr. Richard M. Fry, Directer Commission Division of Radiation Protection 12700 Hagers Ferry Road North Caro!ina Department of Huntersville, North Carolina 28078 Environment, Health and Natural Resources Mr. Peter R. Harden, IV 3825 Barrett Drive Account Sales Manager Raleigh, North Carolina 27609 7721 Westinghouse Electric Corporation Power Systems Field Sales Mr. T. Richard Puryear P. O. Box 7288 Owners Group (NCEMC)

Chariotte, North Carolina 28241 Duke Power Company 4800 Concord Road Dr. John M. Barry York, South Carolina 29745 Mecklenberg County Department of Environmental Protection 700 N. Tryon Street Charlotte, North Carolina 28202