UNITED STATES g

NUCLEAR REGULATORY COMMISSION y

E WASHINGTON, D. C. 20555 b

i

,o CONSUMERS POWER COMPANY PALISADES PLANT DOCKET NO. 50-255 AMENDMENT TO PROVISIONAL OPERATING LICENSE Amendment No.100 l'

License No. DPR-20 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment by Consumers Power Company (the licensee) dated July 9, 1984 complies with the standards and requirements of the Atomic Energy Act of 1954, as amended I

(the Act), and the Comission's rules and regulations set

(

forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public; and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

8702130243 870203 PDR ADOCK 05000255 P

PDR

  • 2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment and Paragraph 3.B. of Provisional Operating License No. DPR-20 is hereby amended to read as follows:

B.

Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No.100, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION l

f,,,

m I

Ash C. Thadani, Director PWR Project Directorate #8 Division of PWR Licensing-B

Attachment:

Changes to the Technical Specifications Date of Issuance: February 3, 1987 l

l l

l l

1 l

l 1

s-ATTACHMENT TO LICENSE AMENDMENT NO.100 PROVISIONAL OPERATING LICENSE NO. DPR-20

. DOCKET NO. 50-255 Revise Appendix A Technical Specifications by removing the page identified

. below and inserting the enclosed page.

The revised page is identified by amendment number and contains marginal lines indicating the area of change.

REMOVE INSERT 6-34 6-34 9

(

1

4 S

6.17 Post Accident Sampling The licensee shall implement a program which will ensure the capability to obtain and analyze reactor coolant, radioactive iodines and particulates in plant gaseous effluents, and containment atmosphere samples under accident conditions. This 4

program shall include the following:

1.

Training of personnel 2.

Procedures for sampling and analysis 3.

Provisions for maintenance of sampling and analytic equipment.

,f i-t l

i l-i I

6-34 Amendment No. 85,100 i

.,