ESADA VALLECITOS EXPERIMENTAL SUPERHEAT REACTOR ANNUAL REPORT NO. 18 (DEACTIVATED),

LICENSE DR-10 DOCKET 50-183 NUCLEAR TECHNOLOGIES & FUEL DIVISION e GENERAL ELECTRIC COMPANY VALLECITOS NUCLEAR CENTER, PLEASANTON, CALIFORNIA 94566 hN M 4020611 851231 1

gDR ADOCR 05000183 PDR L

ESADA Vallecitos Experimental Superheat Reactor Annual Report No. 18 (Deactivated)

General Electric Company has maintained the.ESADA Vallecitos Experimental Superheat Reactor (EVESR) in a deactivated status under the authority of Amendment No. 3 to License DR-10, Docket 50-183, issued June 11, 1976.

In this eighteenth annual report, a summary is presented as to the status of the facility for the period from January 1,1985, to December 31, 1985, as required by Paragraph 3.E.2. of the license.

I.

SUMMARY

The facility remains in essentially the same condition described in the seventeenth annual report. Entry into the containment building was made for routine radiation surveys and a general check of conditions throughout the building. Radiation levels remain essentially unchanged.

II.

STATUS OF THE FACILITY Access to the containment building is controlled by the facility supervisor according to written procedures. The reactor vessel and head storage shield plugs, the wooden cover over the fuel storage pool, and the locked covers for the personnel and equipment hatchways remain in place.

III.

RADIATION AND CONTAMINATION Complete. radiation and contamination surveys of the' facility indicate that ~the levels remain low. Survey results are tabulated in Table.l.

IV.

ACTIVITIES Routine inspections were conducted during this report' period.

V.

ORGANIZATION There were no changes in the organization. E

O EVESR Annual Report No.18 VI.

CONCLUSION The General Electric Company concludes that the deactivated ESADA Vallecitos Experimental Superheat Reac cr is being maintained in a safe shutdown condition. The inspections, access control, and administratively controlled activities ensure maximum pro ection for the public health and safety. The procedures will be continueo co maintain this high level of protection.

GENERAL ELEC RIC COMPANY Irradiati r e;s g Operation

\\

BY

[)PT-1[-

Qf W. litus, Manager Reactor Operations & Support Services

-2

e TABLE 1.

Radiation and Contamination Report Reactor Enclosure 12/84 06/85 12/85

1. Radiation Readings (mR/h gamma) a.

Top of spent fael pool (main floor) 4.0 3.0 3.0 b.

549-ft level (main floor)

<1

<1

<1 c.

534-ft level

<1 1

1 d.

519-ft level

<1 1

<1 e.

503-ft level (maximum pipe reading) 4.0 4.0 4.0 f.

487-ft level (basement)

<1 1

<1

2. Air Samples (uCi/cc air beta-gamma) x 10'10*

a.

Top of spent fuel pool 0.033 0.029 0.052 b.

549-ft level.

0.042

<0.011 0.058 c.

519-ft level 0.055 0.012 0.093 11. 487-ft level 0.042 0.074 0.024

3. Floor Smears (c/m beta-gamma)**

549-ft level

<100/ft2 400/ft2 400/ft2

  • 24-hour decay
    • For conversion to d/m assume an instrument efficiency of 20%.

NOTE: Radiation levels, surface smears and air samples will vary from survey to survey as they are taken in general areas rather that at specific locations.

'6 GENER AL h ELECTRIC NUCLEAR ENERGY BUslNEss OPERATIONS GENERAL ELECTRIC COMPANY e VALLECITOs NUCLEAR CENTER e PLEAsANTON, CAUFORNIA 94566 March 25, 1986 c

Dr. H. R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington,-D.C.

20555

Reference:

License DR-10, Docket 50-183

Dear Dr. Denton:

Enclosed are three signed and nineteen conformed copies of Annual Report No. 18 for the ESADA-Vallecitos Experimental Superheat Reactor (Deactivated).

Sincerely, G. E. Cunningham Senior Licensing Engineer (415) 862-4330

/sjl Encls.

104 Ii l