July 27,1999 LJM:99:085 U.S. Nuclear Regulatory Commission Attn: Ms. N.L. Osgoc d Licensing Section Spent Fuel Office Office of Nucir,ar Material Safety and Safeguards Mail Stop 6 F18 Washington DC 20555-0001 De: r Ms. Osgood:
Subject:
Consolidated License Application; SP 1, SP-2 and SP-3 Shipping Containers - Docket 71-9248 Ref.: 1. Letter, L.J. Maas to C.R. Chappell, "Model SP-1 and SP-2 Packages," dated April 12, 1999 Ref.: 2. Letter, N.L. Osgood to L.J. Maas, "Model SP-1 and SP-2 Packages," dated June 18, 1999 Ref.: 3. Letter, L.J. Maas to N.L. Osgood, "Model SP-1 and SP-2 Packages," dated July 1, 1999 Ref.: 4. Letter, L.J. Maas to N.L. Osgood, "Model SP 1 and SP-2 Packages," dated July 8, 1999 in our original application (reference 1) to amend NRC Certificate of Compliance 9248, Siemens Power Corporation (SPC) analyzed the use of the renamed SP-3 shipping container for fuel assemblies and fuel rods as described in paragraphs 5(b)(1)(i),5(b)(1)(ii) and 5(b)(1)(iv) of the certificate. What follows is our analysis of the SP-3 container using a more specific fuel assembly description and applying the necessary analysis to the use of polyethylene shims as requested in recent conversations.
As a result of conversations you have had with C.D. Manning of SPC regarding the information provided by SPC in references 3 and 4, SPC is amending the application for the shipping containers that were renamed as SP-3 in reference 1. Accordingly, we are submitting six copies of EMF-1563 revision 10 which incorporates the new criticality safety evaluation mentioned previously and incorporated as a revised Appendix 6H. As a result of this evaluation, SPC is requesting an amendment to Certificate of Compliance 9248 to include this 9907290172 990727 PDR ADOCK 07109248 C
PDR Siemens Power Corporation l
\\
1 21o1 Horn Rapids Road Tel:
(509) 375 8100 Richland WA 99352 Fax:
(5o9) 375-8402 1
1
_____________3
'N Ms. N.L. Osgood LJM:99:085 July 27,1999 Page 2 specific fuel assembly type as a new payload category in 5(b)(1)(viii) which will be the only fuel assembly type authoritd for shipment in the SP-3.
The new fuel type which we are requesting to be added as paragraph 5(b)(1)(viii) of the certificate is as follows:
"UO fuei assemblies in a 9x9 square array with a maximum fuel cross-section of 25 2
square inches, maximum fuellength of 174 inches, and a maximum average enrichment of 4.0 w/o U-235. The nominal pellet diameter is 0.370 inch. At least the center 3x3 rod locations shall be a water channel. Each assembly must include at least eight rods with a minimum nominal gadolinia (Gd 0 ) content of 2.0 w/o in all axial regions with 2 3 enriched pellets. Additional gadolinia rod specifications are included in supplement dated July 26,1999."
In addition, a statement should be added to paragraph 7 of the certificate based on this attached evaluation and new fuel type, indicating the following:
"For the contents described in 5(b)(1)(viii), polyethylene shipping shims with a maximum of 13 volume percent polyethylene may be inserted between the rods within the fuel assemblies."
SPC is hoping to mainta'r. the schedule of shipping internationally in the SP 3 by early September of this year. We would appreciate at your earliest convenience notification that this present submittal will not adversely affect the status of your review and our scheduled shipment. If you need additionalinformation, please call me at 509-375-8537 or P.C. Rieke at 509-375-8186.
Ve truly yours,
~
Loren J. Maas, Manager Regulatory Compliance las Enclosures o