ML20210E457

From kanterella
Jump to navigation Jump to search
Summary of Changes,Tests & Experiments Performed at Aerotest Radiography & Research Reactor (Arrr),For Period 980701 Through 990630. with
ML20210E457
Person / Time
Site: Aerotest
Issue date: 06/30/1999
From: Meren A
AEROTEST OPERATIONS, INC.
To:
NRC
References
NUDOCS 9907280226
Download: ML20210E457 (6)


Text

{

l l- .

AEROTEST OPERATIONS,1NC.

3455 FOSTORIA WAY. SAN RAMON. CA 94583. (925) 866-1212. FAX (925) 8661718

%w/

( p-1 July 1999 Director ofInspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D.C. 20555

Subject:

Annual Summary of Changes, Tests and Experiments at Aerotest Radiography and Research Reactor (ARRR), Docket no. 50-228, for the period 1 July 1998 through 30 June 1999 1

i Gentlemen:

The enclosed report summanzes the ARRR operations from July 1,1998 through June 30,1999. This submittal complies with the requirements set forth in 10 CFR, part 50.59 " Authorization of Changes, Tests and Experiments." Summary forms of monthly operations and unscheduled power reductions are included.

No new or unusual problems have been noted during the year and reactor operations have rema'ned stable with respect to safety and reliability.

Sincerely, I

Aerotest Operations, Inc.

j)

"fA/. W Alfre o W. Meren Reactor Supervisor I i fC%O 280050 A SUBSIDIARY OF OEA AEROSPACE,INC.

9907280226 990630 PDR ADOCK 05000228 R

PDR

I' 4

^

Annual Summary of Changes, Tests and Experiments l

Performed at the Aerotest Radiography and Research Reactor 1

i (ARRR)

Docket no. 50-228 by l

l Alfredo W. Meren Reactor Supervisor Approved by b h' a

Ray R. Tsukimura President Aerotest Operations, Inc.

r l

l.

l I

l e

l l

SECTION I 1

t i

i Part I-Changes (none) l

\\

I i

I r

g-i l

l I

l j

Part II - Experiments j

l 1

i No new experiments were performed during the year. The experiments performed in this reporting period were as follows-l Experiment No.

I14 Neutron radiography performed in the radiography facilities.

I16 Irradiation of hydrocarbon activation analysis samples.

120 Irrediation of plastic slides impregnated with microscopic quantities of fissionable materials.

-124 Irradiation of solid state electronic components to determine radiation damage effects.

)

i l

l

SECTION 11 ARRR MONTHLY OPERATIONS

SUMMARY

l Date_ Operating Kilowatt Accumulated Expts. &

Unscheduled Hours Hours KW Hours Irradiations Shutdowns 7-98 178 32,083 10854721 1

2 8-98 169 30,444 10885165 0

0 9-98 176 31,731 10916896 5

2 10-98 182 32,732 10949628 0

1 11-98 151 27,246 10976874 0

1 12-98 189 34,093 11010967 0

2 1-99 177 31864 11042831 0

2 2-99 184 33,177 11076008 0

4 3-99 168 30,295 11106303 0

6 4-99 148 26,645 11132948 0

11 5-99 163 29,250 11162198 0

3 6-99 164 29,601 11191799 0

2

f ARRR UNSCHEDULED POWER REDUCTIONS i

s TYPE OF SCRAM CIIANNEL AFFECTED N O.

DATE AUTO MAN spurinin or. i< niton CAI.

I 2

3 4

i'aitiun =Le l120 COM M ENTS I

7-14-98 X

x ch_ ? novina 2

7-13-98 X

X Ch. 2 period 3

9-11-98 X

X Ch. 2 neriod 4

9-11-98 X

X Ch. 2 neriod 5

10-8-98 X

X Ch.3 90% hich volt 6

11-19-98 X

X X

X X

No visible alarm 7

12-1-98 X

X X

X X

Power outage 8

12-7-98 X

X X

X X

X Power outage 5

1-19-99 X

X X

X X

No visible alarm 10 1-22-99 X

X X

X X

No visible alarm 11 2-16-99 X

X Ch. 2 period 12 2-22-99 X

X X

X X

No visible alarm 13 2-23-99 X

X X

X X

No visible alarm 14 2-27-99 X

X X

X X

No visible alarm 15 3-1-99 X

X X

X X

No visible alarm 16 3-15-99 X

X X

X X

No visible alarm _

17 3-18-99 X

X X

X X

No visible alarm 18 3-19-99 X

X X

X X

No visible alarm 19 3-23-99 X

X X

X X

No visible alarm 20 3-31-99 X

X X

X X

No visible alarm 21 4-9-99 X

X X

X No visible alarm 22 4-9-99 X

X X

X X

No visible alarm 23 4-12-99 X

X X

X X

No visible alarm 24 4-13-99 X

X X

X X

No visible alarm 25 4-13-99 X

X X

X X

No visible alarm 26 4-14-99 X

X X

X X

No visi' ole alarm 27 4-17-99 X

X X

X X

No visible alarm 28 4-19-99 X

X Ch. 2 period 29 4-26-99 X

X X

X X

No visible alarm 30 4-27-99 X

X X

X X

No visible alarm 31 4-27-99 X

X X

X X

No visible alarm 32 5-5-99 X

X X

X X

No visible alarm 33 5-13-99 X

X X

X X

No visible alarm 34 5-17-99 X

X X

X X

No visible alarm 35 6-1-99 X

X X

X X

No visible alarm 36 6-3-99 X

X X

X X

No visible alarm 37 f

JN I

39 an UN ron ul'p.NI.s