Suc UNITED STATES
+
E
'g NUCLEAR REGULATORY COMfMSSION
~
WASHINGTON. D. C. 20555 h
k j
ARKANSAS POWER & LIGHT COMPANY DOCKET NO. 50-368 ARKANSAS NUCLEAR ONE, UNIT ?
AMEN 0 MENT TO FACILITY OPERATING LI.CFNSE Amendmenc No. 80 License No. NPF-6 1.
The Nuclear Regulatory Commission (the Comission) has found that:
A.
The application for amendment by Arkanscs Nwer & Light Company (the licensee) dated April 25, 1986 as supplemented May 23, 1986, complies with the standards and requirements cc.' tM Atonic Energy Act of 1954, as amended (the Act), and the Ct.w.ission's regula-tions set forth in 10 CFR Chapter I; B.
. The facility will operate in confonnity with the application, the provisions of the Act, and the regulations of the Commission; C.
There is reasonable assurance (i) that the actitities authorized by this amendment can be conducted without er.dengerinc; the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commissioii's regulationse, D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by chEiges to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-E is hereby amended to read as follows:
(2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No.
80, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.
man 91901C2 860,9 1 n p[)h AD0cK vovv g P
a.
2-l 3.
This license amendment is effective as of the date of its issuance.
FOR.THE NUCLEAR REGULATORY COMMISS10N r
/
Robert 5, Lee, Project Manager PWR Project Directorate No. 7 Division of PWR Licensing-B
Attachment:
Changes to the Technical Specifications Date of Issuance: September 10, 1986 i
b l
P
.m
.,..,,-.-,,r,
September 10, 1986 ATTACHMENT TO LICENSE AMENDMENT N0.80 FACILITY OPERATING LICENSE N0. NPF-6 DOCKET NO. 50-368 Replace the following page of the Appendix "A" Technical Specifications with the enclosed page. The revised page is identified by amendment number and contains vertical lines indicating the areas of change. The corresponding overleaf page is also provided to maintain document completeness.
Remove Page Insert-Page 3/4 1-5 3/4 1-5 E
I
1 l
I REACTIVITY CONTROL' SYSTEMS H00ERATOP. TEMPERATURE _ COEFFICIENT 4
LD1ITIhG CONDITION FOR OPERATION 3.1.1.4 - The 7.oderator temperature coefficient (MTC) shall be:
Less positive than 0.5x10-4 dh/"F whenever THERMAL a.
POWER is <70% of RATED THERMAL POWER, b.
Less pcsitive than 0.0 ak/k/ F whenever THERMAL POWER is 370". of RATED THERMAL POWER, and Less reg:tive than -3.4x10' ak/k/ r at RATED THERMAL c.
- POWER, I
APPLICABILITY:
MODES 'I and 2*.
I ACTION:
With the moderator temperature coefficient outside any one of the above limits, be in at least HOT STANDBY within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, SURVEJJLLANCE REQUIREMENTS 4.1.1.4.1 The MTC shall be detena.ined to be within its limits by confirmatory l
neasurenents. MTC measured values shall be eltracel3ted and/or compensated to permit direct comparison with the above #timits.
< 4.1.1.4.E The MTC shall be det6rmined at the folloving *~equencies and THERMAL POWER conditions durir.g each fuel cycle:
o a.
Prior to initial operation above 5% of RATED THERMAL POWER, after each fuel loading, b.
At any THER'iAL POWER, within 7 EFPD af ter reaching a RATED THERMAL POWER equilibrium boror. concentration 9f 800 ppn.
c, At any THERMAL POWER, within 7 EFF0 after reaching a FATED THERMAL POWER equilibriumboron concentraticn of 300 pps
- With Kgff > 1.0.
ARKANSAS - UNIT 2 3/4 1-5 Amendment No. 74 80
.