Monthly Operating Repts for June 1986
ML20209F439
Person / Time
Site: Prairie Island  
Issue date: 06/30/1986
From: Dugstad D, Musolf D
NORTHERN STATES POWER CO.
To:
NRC OFFICE OF RESOURCE MANAGEMENT (ORM)
References
NUDOCS 8609120153
Download: ML20209F439 (9)


Text

_

i 4

f HeBEeIIVE_SuddeEY_DE_DEEEeIING_EXEEBIENCE i

DOCKET NO. 50-282 UNIT PRAIRIE ISLAND NO.i DATE JULY 2, 1986 COMPLETED'BY DALE DUGSTAD TELEPHONE 612-388-1121

'~

)

MONIU1.__ JUNE _._____1E86_

1 l

THE UNIT WAS BASE LOADED THIS MONTH. NO SHUTDOWNS.

i 4

I f

i l

i l

l I

i.

8609120153 860630 PDR ADOCK 05000282 R

PDR

,. _ _ _. __.. _ _.. _ _.. -.. ~.,. - _.. _. _. _ _ _, _.,.

4 DEEEGIING DGIe_8EEOR'I DOCKET kO. 50-202 i

i-UNIT PRAIRIE ISLAND N0.1 DATE JULY 2, 1986 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-1121 QRE8eIING_SIGIUS

i. UNIT NAME:

EBoIBIE_ISLOND_ND._1

2. REPORTING PERIOD:__ JUNE ______1286_.._

l NOTES:

l

3. ITCFNSFD THFRMAl POWFR (MWT):

iASO I

I

4. NAMEPLATE RATING (GROSS MWE)-

593 l

l

5. DESIGN ELECTRICAL RATING (NET MWE)-

530 l

l

6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE). 534 1

1

7. MAXIMUM DEPENDABLE CAPACITY (NET MWE)-

503

.1 i

S.

IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS NUMDER 3 THROUGH 7)

SINCE LAST REPORT GIVE REASON: N O N E _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _.. _.. _ _ _ _ _ _ _ _ _ _

9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE)

_NONE______________

10. REASONS FOR RESTRICTIONS, IF ANY:_ UONE_____ ___ __ ___.......

ISIS _dQUIH

%B:IO:DoIE Cudul6IIVE it. HOURS IN REPORTING PERIOD 720 4343 109919

12. NUMBER OF HOURS REACTOR WAS CRITICAL 720.0 3495.4 90052.9
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 5571.1
10. HOURS GENERATOR ON-LINE 720.0 3472.5 89474.9
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0 is. GROSS THERMAL ENERGY GENERATED (MWH) 1181914 5042401 140411014
17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 383310 1660410 45061600
10. NET ELECTRICAL ENERGY GENERATED (MWH) 359692 1554545 42982379 1?. UNIT SERVICE FACTOR 100.0 80.0 81.4
20. UNIT AVAILABILITY FACTOR 100.0 80.0 81.4
21. UNIT CAPACITY FACTOR (USING MDC. NET) 99.3 71.2 77.7
32. UNIT CAPACITY FACTOR (USING DER NET) 94.3 67.5 73.0
23. UNIT FORCED OUTAGE RATE 0.0 0.2 7.3 M. FORCED OUTAGE HOURS 0.0 6.1 7094.1
45. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE 6 DURATION OF EACH)-

i

_____________________l___..____NLe_____________________________________

36. IF CURRENTLY SHUTDOWN ESTIMATED STARTUP DATE:________NZG_ _____________

't eVEBeGE_DeILY_UNII_EDWEE_ LEVEL i

DOCKET NO.-50-292 l

UNIT PRAIRIE ISLAND B0.1 (1-DATE JULY 2, 1986 3

COMPLETED BY DALE DUGSTAD

(

TELEPHONE 612-388-1121

(

t i

MONIH1__ JUNE ______1286__

i DeX eVEEeGE_D6ILY_EQWEB_ LEVEL _1bWE:NEIl

i iI i

499 (l

2 504 1[

Il 3

502 l_1 4

500 3

5 500 I

6 504 7

501 8

497 9

509 I

10 490 11 502 12 499

!IVE i3 503 l

14 498

[91 9 15 469 52.9 16 500 11.1 i'4.9 17 474 0.0 18 499 1014 19 501 1680 20 497 2379 i

21 500 31.4 22 504 31. 4 23 502 77.7 24 506 73.8 25 505 7.3 26 504 74.1 27 503 28 504 29 503 30 509 I

AVERAGE LOADS ABOVE 503 MWE-NET ARE DUE t

TO COOLER CONDENSER CIRCULATING WATER l

1 i

UNII_SUUIDOWNS_eND_EQWE8_8EDUCIION DOCKET NO 50-282 UNIT NAME E8eIEIE_ISLGND_NO.1 DATE JULY _2i_1296______

COMPLETED BY DELE _DUGSIeD TELLEPHONE 612_3BB_1121 MONIU1_ JUNE ______1286______

DeIE IXEE HOUES BEeSON dEIUQD LEB_NudDES SYSIEd CQbEQUENI YY/MM/DD 000.0 86/06/10 S

0.0 B

5 N/A N/A N/A TURBINE OVERSPEED TRIP TEST.

86/06/15 S

0.0 B

5 N/A N/A N/A TURBINE VALVES TEST.

86/06/i7 5

0.0 B

5 N/A N/A N/A AXIAL OFFSET TEST.

86/06/20 S

0.0 B

5 N/A N/A N/A AXIAL OFFSET CALIBRATION.

SYSIEd_ CODE dEIUOD IXEE BEeSON DRAFT IEEE STD 1-MANUAL 805-1984(P805-D5)

F-FORCED A-EQUIPMENT FAILURE 2-MANUAL TRIP B-MAINTENANCE OR TEST 3-AUTO TRIP S-SCHED C-REFUELING 4-CONTINUED D-REGULATORY RESTRICTION 5-REDUCED LOAD COMEONENI_ CODE E-OPERATOR TRAINING &

9-0THER LICENSE EXAMINATION IEEE STD 803A-1983 F-ADMINISTRATIVE G-OPERATOR ERROR H-0THER

P NoE8eI1YE_SubdoEY_QE_QEE8aIING_EXEEBIENCE DOCKET NO. 50-306 UNIT PRAIRIE ISLAND N0.2 DATE JULY 2, 1986 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-1121 M O NIH 1.._ J U N E _ _ _ _ _ _129 6_ __

THE UNIT WAS BASE LOADED THIS MONTH, NO SHUTDOWNS.

eMEEeGE_DeILY_UNII_EQWEE_ LEVEL DOCKET NO. 50-306 UNIT PRAIRIE ISLAND NO.2 DATE JULY 2, 1986 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-1121 1

tiONItil__ JUNE ______1286__

1 DeX eMEEeGE_DeILY_EQWEE_LEYEL_idWE:UEIl i

495 l

2 504 3

502 4

500 5

502 6

502 7

499 8

499 9

509 10 489 ii 502 12 502 13 504 iA A99 15 498 16 509 17 510 18 502 19 503 20 501 21 501 22 466 23 505 24 510 25 506 26 502 27 501 28 502 29 503 30 507 AVERAGE LOADS ABOVE 500 MWE-NET ARE DUE TO COOLER CONDENSER CIRCULATING WATER

~-

/

DEEEeIING_DeIe_EEEQEI DOCKET NO. 50-306-UNIT PRAIRIE ISLAND NQ 2 i

DATE JULY 2, 1986 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-1121 OEEEeIING_SIeIUS 4

i.

1. UNIT NAME:

EEeIBIE_ISLeND_UD._2

2. REPORTING PERIOD:__ JUNE ______1286___

l NOTES:

1 1

3. LICENSED THERMAL POWER (MWT)-

1650 l

l 4.

NAMEPLATE RATING (GROSS MWE):

593 l

l

5. DESIGN ELECTRICAL RATING (NET MWE):

530 l

l

6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE): 531 I

l

7. MAXIMUM DEPENDABLE CAPACITY (NET MWE)-

500 1____________________1.

8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS NUMBER 3 THROUGH 7)

SINCE LAST REPORT GIVE REASON:__NONE______________________________

9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE):__NQUE______________
10. REASONS FOR RESTRICTIONS, IF ANY:__NQUE_______________________________

IHIS_dQUIU YE:IQ:DeIE CUbuLeIIVE

11. HOURS IN REPORTING PERIOD 720 4343 101037
12. NUMBER OF HOURS REACTOR WAS CRITICAL 720.0 4321.0 87824.3
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 1516.1
14. HOURS GENERATOR ON-LINE 720.0 4315.9 86818.4
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0 i

-16. GROSS THERMAL-ENERGY GENERATED (MWH) 1180948 7070751 136743142

17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 383120 2351140 44077220
18. NET ELECTRICAL ENERGY GENERATED (MWH) 360808 2228193 41717480
19. UNIT SERVICE FACTOR 100.0 99.4 85.9
20. UNIT AVAILABILITY FACTOR 100.0 99.4 85.9
21. UNIT CAPACITY FACTOR (USING MDC NET) 100.2 102.6 82.6
22. UNIT CAPACITY FACTOR (USING DER NET) 94.6 96.8 77.9
23. UNIT FORCED OUTAGE RATE O.0 0.6 3.6
24. FORCED OUTAGE HOURS 0.0 27.1 3236.7
25. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE & DURATION OF EACH):

______________________BEEUELING_IN_QCIDBEB____________________..________

26. IF CURRENTLY SHUTDOWN ESTIMATED STARTUP DATEl___Ule___________________

i

a UNII_SHUIDOWNS_eND_EQUEB_EEDUCIION DOCKET NO 50:306 UNIT NAME EBeIEIE_ISLeND_NO 2 DATE JULY _2._1286______

COMPLETED BY DELE _DUGSIeD TELLEPHONE 612_388 1121 MONIH1_ JUNE __ ___1286 _____

DeIE IYEE HOUBS BEeSON MEIHOD LEE _NUdBEB SYSIEd CQdEONENI YY/MM/DD 000.0 86/06/22 S

0.0 B-5 N/A N/A N/A TURBINE VALVES TEST.

4 IYEE BEeSON dEIBOD SYSIEd_ CODE F-FORCED A-EQUIPMENT FAILURE i-MANUAL DRAFT IEEE STD S-SCHED B-MAINTENANCE OR TEST 2-MANUAL TRIP 805-1984(P805-DS)-

C-REFUELING 3-AUTO TRIP D-REGULATORY RESTRICTION 4-CONTINUED E-OPERATOR TRAINING &

5-REDUCED LOAD COMEONENI_ CODE LICENSE EXAMINATION 9-0THER F-ADMINISTRATIVE IEEE STD 803A-1983 G-OPERATOR ERROR H-0THER

O Northem States Power Company 414 Nicollet Mall Minneapoks, Minnesota 55401 Telephone (612) 330 5500 July 8, 1986 Director, Office of Resource Management U S Nuclear Regulatory Commission Washington, DC 20555 PRAIRIE ISLAND NUCLEAR GENERATING PLANT Docket No. 50-282 License No. DPR-42 50-306 DPR-60 Monthly Operating Report June, 1986 Attached are twelve copies of the Monthly Operating Report for June, 1986 for the Prairie Island Nuclear Generating Plant.

DO w.

David Musolf Manager of Nuclear Support Services DMM/EFE/jlk cc: Regional Administrator-III, NRC NRR Project Manager, NRC NRC Resident Inspector MPCA Attn: J W Ferman Attachment 4

/