ML20209E219
| ML20209E219 | |
| Person / Time | |
|---|---|
| Site: | 07109154 |
| Issue date: | 08/29/1986 |
| From: | Macdonald C NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| To: | |
| Shared Package | |
| ML20209E212 | List: |
| References | |
| NUDOCS 8609100117 | |
| Download: ML20209E219 (1) | |
Text
_______________________.--___,________mmm__mmy I
U.S. NUCLEAR LEIULATCRY COMMISSCN NRCFORMs1s I
- ass CERTIFICATE OF COMPLIANCE T
I
C'"7' FOR RADIOACTIVE MATERIALS PACKAGES T
1 a CERTIFICATE NUMBER D REVISION NUMBER c PACKAGE IDENTIFICATION NUMBER a PAGE NUMBER
- e. TOTAL NUMBER PAGES g
9154 3
USA /9154/B(U) 1 2
g I
I a PREAustE g
- a. This certificate is issued to certify fu t the packaging and contents desenbed in item 5 below, meets the applicable safety standards set forth in Title 10. Code
[
g of Federal Regulations Part 71. Pact aG:ng and Transportation of Radioactive Matenal" II N
- b. This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or otner l
appiscabie reguistory agencies. inc'uding the government of any country inrouan or into wnica the packsoe wiii be transported-I l
t i
F 1
L 3 THIS CERTIFICATE l$ ISSUED ON THE BASIS OF A SAFETY ANALYSIS REPORT OF THE PACKAGE DESIGN OR APPLICATION I
a ISSUEo TO IName end Adeessi D TITLE AND IDENTIFICATION OF REPORT OR APPLICATION I
g Amersham Corporation Technical Operations, Inc. appi :ation dated l
40 florth Avenue October 29, 1981.
I I
Burlington, itA 01803 i
l i
I I
71-9154 l
I
- c. DOCKET NUMBER a CONDITIONS I
This certif cate is conditional upon fulfilling the requirements of 10 CFR Part 71, as applicable. and the conditions specified below.
1 I
l s t
g (a) Packaging i
I (1) Model No. :
858 l
1 l
l (2) Description l
V 1
A steel encased, uranium shielded Ganna R'ay Projector.
Primary com-l g
g oonents consist of an outer steel shell (21" x 12" x 14.62"), internal I
bracing, nolyurethane potting material, depleted uranium shield (4.0" min.
I thickness), and a Zircalloy "S" tube (0.467" OD x 0.385" ID).
The I
contents are securely positioned in the Zircalloy "S" tube by a source l
cable locking device and shipping plug. Tamper-proof seal s are provided t
g on the packaging and a 1/4-inch thick steel shipping plate is bolted t
g over the source locking nechanism for additional protection during t
I transport. The total weight of the package is approximately 502 pounds.
I I
t l
(3) Drawi ngs f
I li g
The packaging is constructed in accordance with the following Technical g
il Operations, Inc. Drawi ng flos.:
E I
t I
85890, Sheets 1, 2, 3, 4, 5, and 6 of 6, Rev. O I
I I
66025, Sheets 2 and 3 of 3, Rev. A.
I I
I L
l f
1 I
I I
I I
I I
I L
I I
I L
g 8609100117 860829 g
C I
L I
L I
l
\\
z usa-----
l I
CONotTIONS (continued) ll f,l l
Page 2 - Certificate Ho. 9154 - Revision No. 3 - Docket No. 71-9154 i
I I
I I
l l
S.
(b) Contents I
I I
(1) Type and form of material y
I I
I Cobalt 60 as sealed sources which meet the requirements of special form I
I radicactive material.
's (2) Maximun quantity of material per package l
I I
i 110 curies l
I I
l 6.
The source must he secured in the shielded position of the packaging by the a
y shipping plug, source assembly, and locking device. The shipping plug, source I
I assembly used must be fabricated of materials capable of resisting a 1475*F fire l
l environment for one-hal f hour and maintaining their positioning function. The y
I ball stop of the source assembly must engage the locking device. The flexible i
I cable of the source assembly and shipping plug must be of sufficient length and l
l diameter to provide positive positioning of the source in the shielded position.
I 7.
The nameplates must be fabricated of materials capable of resisting the fire test l
l of 10 CFR Part 71 and maintaining their legibility.
g I
8.
The package authorized by this certificate is hereby approved for use under the N
general license provisions of 10 CFR $71.12.
I I
9.
Expiration date: August 31, 1991.
l I
I REFERENCE I
I Technical Operations, Inc. application dated October 29, 1981.
l l
FOR THE U.S. NUCLEAR REGULATORY COMMISSION N
I
=h I
Charles E. MacDonald, Chief Transportation Certification Branch l
Division of Fuel Cycle and y
Material Safety, HMSS lN i
Date:
D2iE I
N N
N B
W l
5
,o l
,i,l 5
N tF l
il
- s L= =_ _
in
=============--- ---- ------..---.....-............ 3
1.- _
,g Transportation Certification Branch Approval Record liodel 40. 858 Packaging Docket flo. 71-9154 By application dated August 11, 1986, Amershan Corporation requested renewal of Certificate of Compliance flo. 9154
?!o changes have been requested or nade to the package since approval of Technical Operations, Inc. (now Amershan Corporation) application dated October 29, 1981.
The present certificate holder, U.S. Department of Energy, has advised the iMC that they would not request renewal of the certificate. Amersham Corporation will therefore become the certificate holder of record.
The staff concludes that the ' statements of the original application dated October 29, 1981, satisfy the requirement for renewal of the certificate of compliance.
Y Charles E. PiacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety, ilMSS Date:
4 e,
,e,
,e p-e n-,-~--,.w-m m--n
-